arXiv:2611.00410
Measurement-angle control of a continuously monitored quantum oscillator: purification limits and optimal protocols
Ralph Sabbagh, Olga Movilla Miangolarra, Andrew N. Jordan, Tryphon T. Georgiou
Abstract
We study the dynamic purification of a continuously monitored quantum harmonic oscillator coupled to a thermal bath, where the control is the quadrature measurement angle of up to two detectors with prescribed strengths and efficiencies. Within the Gaussian regime, the conditional state covariance obeys a deterministic Riccati equation, and we ask what purity can be reached and sustained by manipulating the angle in time, in analogy with rapid-purification protocols for qubits. We propose, analyze, and compare constant-rate, greedy, vibrational, and variational monitoring strategies on the basis of sustained purity starting from the thermal bath state, and quantify to what extent they are able to maintain higher purity levels compared to lab-fixed or phase-locked detectors. We highlight structural features, operational limits, and optimal protocols from each strategy and study how model parameters shape control performance. We observe that in the absence of measurement-frame anisotropy, the time-dependent strategies achieve higher but similar performance. Once this symmetry is broken, their performances diverge, either improving or worsening depending on the relative timescales of oscillator dynamics, thermalization, and measurement.
AI Summary
Can changing only the measured quadrature angle improve the sustained conditional purity of a thermally damped harmonic oscillator with fixed detector strengths and efficiencies? In the Gaussian regime, covariance evolution is a deterministic Riccati equation, so angle protocols can be precomputed without measurement-record feedback. The paper compares constant-rate rotation, high-frequency sinusoidal modulation, instantaneous-purity-maximizing greedy control, and finite-horizon variational control maximizing time-averaged logarithmic purity. For an isotropic measurement frame, and assuming the stronger detector is also more efficient and effective detector quality exceeds bath quality, exact Riccati analysis shows that sustained purity and relaxation rate increase with oscillator–detector relative rotation speed. Rapid rotation produces an isotropic effective measurement. Writing $\nu$ for measurement-to-bath strength and $q$ for detector-to-bath quality, the fraction $\mathcal G$ of the purity improvement from thermal purity toward effective-detector purity satisfies $\nu/(1+\nu)<\mathcal G<\sqrt{\nu/(\nu+2)}$. Sinusoidal modulation with amplitude approximately $1.2024$ radians realizes the same averaged measurement; this is optimal within the high-frequency vibrational family. Greedy and numerically optimized variational protocols approach similar isotropic performance. Measurement-frame anisotropy can improve or degrade purity and separates the protocols’ performances. Averaging calculations and numerical comparisons show that biased vibrational mixing can outperform uniform rotation, while variational control outperforms greedy control in the representative anisotropic cases. The analysis is restricted to a single Gaussian mode. Pontryagin conditions and forward–backward numerical optimization do not establish global finite-horizon optimality. High-frequency protocols require rates exceeding covariance-evolution scales; bandwidth and latency constraints, multimode systems, and non-Gaussian record-dependent feedback remain extensions.
Error found: The abstract suggests optimal protocols are established for every strategy, although the variational analysis provides necessary conditions and numerical candidates rather than a certified global optimum.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 24 pages, 13 figures