arXiv:2610.38878
Drive-tunable Floquet exchange spectroscopy with Hong--Ou--Mandel interference
Eric R Bittner
Abstract
Floquet driving reshapes cavity spectra, but single-photon sideband populations do not reveal how it changes two-photon exchange. Here we show theoretically that delay-resolved Hong--Ou--Mandel (HOM) coincidences can probe this response in a collectively coupled cavity. A frequency-entangled signal photon scatters linearly from the driven cavity while its idler provides a delayed reference. Averaging over an unsynchronized drive phase removes coherence between different net output orders but preserves exchange interference within each order. Fourier transformation of the coincidence trace yields two drive-dependent exchange branches associated with the Floquet-polariton spectrum. As the drive changes, the branches shift and exchange weight; the dominant physical output order also changes, a transfer not reproduced by single-photon sideband populations. We further map the coincidence-trace response over drive frequency and amplitude and connect it to a count-model-dependent Fisher information. Floquet control thus adds a tunable exchange spectrum to HOM interferometry and gives quantitative targets for an experiment.
AI Summary
The paper asks how periodic cavity driving changes two-photon exchange interference beyond what single-photon Floquet-sideband populations reveal. It models a frequency-entangled pair with one photon transmitted through a driven, collectively coupled cavity and the other serving as a delayed reference in Hong–Ou–Mandel (HOM) interferometry. Linear Floquet input–output equations determine the transmitted amplitudes; averaging over an unsynchronized drive phase removes coherence between different net frequency-shift orders while retaining exchange interference within each order. Numerical delay scans and their Fourier transforms yield two dominant exchange-frequency branches associated with the driven polariton pair. In the studied parameter window, their frequencies satisfy $\nu_{\rm ext}+\nu_{\rm fold}=2\Omega$; this is not proposed as a universal selection rule. Varying the drive shifts the branches and redistributes their weights. The folded branch’s dominant physical output order changes from $n=+1$ to $n=0$, unlike the single-photon sideband populations. Representative calculations use $G=1.5\kappa$, $\gamma=0.1\kappa$, and modulation amplitude $A=2.385\kappa$. An unweighted coincidence-trace response metric maps sensitivity to drive controls, separately from a throughput-dependent Fisher-information model. The mechanism requires neither photon–photon interactions nor cavity saturation. Predictions assume a homogeneous bright mode, one cavity resonance, weak excitation, and transmission-conditioned detection. Disorder, additional modes, loss, and detector response can alter the spectra. A representative device mapping requires a $70.8\,\mathrm{GHz}$ drive and $76.8\,\mathrm{GHz}$ frequency excursion, with predicted transmission of $15.2\%$. No experimental realization or sensing advantage is established.
Error found: For the stated resonant model and symmetric Gaussian input, opposite Floquet output orders have identical populations and HOM exchange contributions, so n=+1 cannot be uniquely dominant over n=-1. The exchange integrals X_n(τ), and therefore Z(τ), are identically real, contradicting the paper's interpretation of Z as carrying additional complex-phase rotation.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.