arXiv:2610.31811
Photoelectrons resolve the phase-dependent variance of bright squeezed vacuum
Haoran Ma, Yihe Wang, Chuan Cheng, Ian Gabalski, Aaron M. Ghrist, Eleanor Weckwerth, Mohammed Th. Hassan, Philip H. Bucksbaum
Abstract
The variance of bright squeezed vacuum (BSV) is not only strong but also phase dependent, yet recent strong-field experiments with BSV have recorded only its magnitude. A coherent field of the same color provides the phase reference that resolves this phase-dependent noise. Strong-field ionization of xenon by this light shows that the photoelectron yield follows the BSV quadrature along the coherent field, and that the nonlinearity of ionization amplifies the quadrature noise many times over in the electron yield. The noise is moreover distributed unevenly over the photoelectron momentum distribution, differing by an order of magnitude between ionization channels. Strong-field ionization thus offers a phase-sensitive, channel-resolved detector of quantum light, while the quadrature noise of quantum light offers a probe of the intensity dependence of individual ionization pathways.
AI Summary
The paper asks whether strong-field ionization can resolve the phase-dependent fluctuations of bright squeezed vacuum (BSV), rather than only its photon-number noise. BSV is superposed with a same-frequency coherent reference and focused into xenon. Single-shot optical interferometry records the BSV amplitude and relative phase, while a velocity-map detector records photoelectron momenta. Sorting the drifting relative phase selects predominantly amplitude- or phase-squeezed displaced BSV. The field-correlated rms electron-yield noise decreases from approximately 40% to 10% as the noisy BSV axis rotates from parallel to perpendicular to the coherent field. Thus, the yield predominantly reads out the BSV quadrature along the coherent field. An rms BSV field only approximately 2.6% of the coherent amplitude produces roughly one-third rms yield modulation. Momentum-resolved measurements reveal strong channel dependence: the normalized yield variance $g^{(2)}-1$ is $0.51\pm0.03$ for non-resonant electrons, $0.17\pm0.01$ at the 4f Freeman resonance, and $0.015\pm0.011$ at the 5f satellite. Focal-volume-averaged single-active-electron TDSE calculations reproduce the spectral structure and noise ordering using a fitted BSV amplitude of 2.9%. The interpretation relates variance to the squared local logarithmic intensity slope of each channel; resonance thresholds and focal geometry explain their different sensitivities. The measurement isolates field-correlated variance by subtracting finite-bin sampling noise. Optical resolution exceeds the quiet-quadrature width, and the BSV amplitude calibration carries approximately 25% uncertainty. Only amplitude-noise transfer is demonstrated: sensitivity to the orthogonal, phase-noise quadrature remains a proposed extension.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 6 pages, 3 figures