arXiv:2610.29980
International atomic clock comparison achieving $5\times 10^{-18}$ uncertainty
A. Tofful, M. Filzinger, T. Schmidt, A. Amy-Klein, E. Benkler, E. Cantin, C. Chardonnet, E. A. Curtis, H. Denker, B. Dutta, J. -O. Gaudron, W. Huang, J. Kronjäger, A. Kuhl, R. Le Targat, B. Lipphardt, O. Lopez, S. Mukherjee, A. L. Parke, B. Pointard, P. -E. Pottie, P. J. Regan, M. Risaro, M. Schioppo, M. Steinel, J. Tunesi, X. Zhang, R. M. Godun, N. Huntemann
Abstract
Two single-ion optical clocks, located in the United Kingdom and in Germany, are compared remotely via a 2220\,km long optical fiber link. Both clocks are based on the ${}^2S_{1/2} (F=0)\leftrightarrow {}^2F_{7/2} (F=3)$ electric octupole (E3) transition in $^{171}\text{Yb}^+$. Using more than $10^6$ seconds of measurement data, we determine a fractional frequency difference of $1.0(4.8)\times 10^{-18}$, demonstrating agreement of the independently developed systems. To our knowledge, this constitutes the first international clock comparison reaching a fractional uncertainty below $5\times 10^{-18}$, an important milestone towards an anticipated optical redefinition of the SI second. The measurement uncertainty is dominated by that of the relativistic redshift correction between the two sites, which includes time-varying gravity potential differences. We exploit the large baseline between the two clocks to search for violations of Lorentz invariance. In the absence of statistically significant modulations, we improve constraints on the Robertson-Mansouri-Sexl parameter $α$ by approximately a factor of five in the uncertainty, and provide limits on corresponding parameters within the Standard-Model Extension framework.
AI Summary
The paper tests whether independently developed optical clocks in different countries agree below $5\times10^{-18}$ fractional uncertainty, a target for an optical redefinition of the SI second. It compares two single-ion $^{171}\mathrm{Yb}^+$ electric-octupole clocks in the UK and Germany through a 2220 km phase-stabilized optical-fiber link. The clocks use different traps, laser references, and probe-light-shift cancellation methods. The comparison collected $1.09\times10^6$ seconds of valid data over 24.7 days, with 51% combined uptime. After systematic and relativistic corrections, the fractional frequency difference is $1.0(4.8)\times10^{-18}$. The statistical uncertainty is $1.6\times10^{-18}$, inferred from white-frequency-noise scaling beyond 1000 s. Common black-body-radiation uncertainty is treated as correlated. The largest uncertainty contribution, $3.5\times10^{-18}$, comes from the differential gravitational redshift, including time-dependent tidal corrections, and corresponds to just over 3 cm in relative geopotential height. Checks of non-Gaussian link noise, data gaps, and uneven daily sampling find no significant bias. Fits to daily modulation signals find no statistically significant Lorentz-invariance violation. The Robertson–Mansouri–Sexl parameter is $\alpha=-2.4(2.3)\times10^{-9}$, improving its uncertainty by approximately fivefold. A complementary Standard-Model Extension analysis gives $(\xi-\beta)=-2.4(2.0)\times10^{-5}$. Single-coefficient bounds improve previous identical-clock remote comparisons but remain weaker than existing comparisons of different transitions. Their nuclear-sector interpretation uses a hydrogenic approximation and neglects nuclear structure. Further improvement in remote comparison accuracy is limited primarily by knowledge of the gravitational potential; transporting a clock for a colocated comparison is identified as an alternative.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 10 pages, 7 figures