Operational Meaning of the Mandelstam-Tamm Time Scale in a Spin-1/2 Clock

Jakub Rog

quant-phSubmitted Oct 16, 2026• Announced Oct 19, 2026• 0 citations
arXivHTMLPDF

Abstract

Georgiev's analysis of a freely precessing spin correctly emphasizes that the Mandelstam-Tamm quantity $ΔT=Δ\hat A/|d\langle\hat A\rangle/d t|$ is not the variance of a time operator. He concludes, however, that its divergence near the extrema of the clock signal is devoid of physical meaning and that $ΔT$ does not disclose how well the system measures the passage of time. For the same projective $\hatσ_x$ readout, we show that $ΔT$ equals the inverse square root of the classical Fisher information in one binary outcome at regular operating points. Its divergence at submaximal-coherence extrema therefore identifies a loss of local sensitivity in the selected readout, not an infinite variance of physical time; a complementary $\hatσ_y$ measurement remains informative. This interpretation also separates Georgiev's exactly known tick--tock period from the statistical precision with which a tick can be located. It preserves his warning against a time-operator interpretation while qualifying his stronger conclusion that the Mandelstam--Tamm scale lacks physical content.

AI Summary

This comment addresses whether the divergence of the Mandelstam–Tamm scale $\Delta T=\Delta A/|d\langle A\rangle/dt|$ makes it physically meaningless as a measure of clock performance. It revisits a freely precessing pure spin-$1/2$ with Hamiltonian $H=\hbar\omega\sigma_z/2$, coherence $C=2|\alpha_1\alpha_2|$, and projective $\sigma_x$ readout, distinguishing local timing sensitivity from a time-operator variance or a calibrated tick–tock interval. Using the binary outcome probabilities, it derives the classical Fisher information $F_x=\omega^2C^2\sin^2\vartheta/(1-C^2\cos^2\vartheta)$ and establishes $\Delta T=1/\sqrt{F_x}$ at regular, locally identifiable operating points. The pure-state quantum Fisher information is $F_Q=4(\Delta H)^2/\hbar^2=\omega^2C^2$, so the Mandelstam–Tamm bound becomes $\Delta T\Delta H=(\hbar/2)\sqrt{F_Q/F_x}\geq\hbar/2$. For $N$ independent preparations, locally unbiased estimators satisfy $\operatorname{Var}(\hat t)\geq\Delta T^2/N$. For $0<C<1$, the divergence at signal extrema corresponds to $F_x=0$: the readout loses first-order timing sensitivity although the state retains information. A complementary $\sigma_y$ measurement attains $F_Q$ there. The known half-period $\pi/\omega$ therefore does not determine tick-localization precision. The discussion explicitly limits the estimator interpretation to regular local models: extrema require separate treatment, including the $C=1$ zero-over-zero case. Finite-sample effects, bias, periodic ambiguities, and phase knowledge needed for adaptive readout are not resolved; energy variance equals the quantum Fisher-information scale only for the pure-state setting considered.

Little sign of AI-generated textIncremental

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Journal reference
Symmetry 2026, 18(11), 1762
DOI
10.3390/sym18111762
Comments
A Comment on Georgiev, Symmetry (16), 100 (2024)

Related papers

Time–Energy Uncertainty Relation in Nonrelativistic Quantum Mechanics

Danko Dimchev Georgiev

The time–energy uncertainty relation in nonrelativistic quantum mechanics has been intensely debated with regard to its formal derivation, validity, and physical meaning. Here, we analyze two formal relations proposed by Mandelstam and Tamm and by Margolus and Levitin and evaluate their validity using a minimal quantum toy model composed of a single qubit inside an external magnetic field. We show that the ℓ1 norm of energy coherence C is invariant with respect to the unitary evolution of the quantum state. Thus, the ℓ1 norm of energy coherence C of an initial quantum state is useful for the classification of the ability of quantum observables to change in time or the ability of the quantum state to evolve into an orthogonal state. In the single-qubit toy model, for quantum states with the submaximal ℓ1 norm of energy coherence, C<1, the Mandelstam–Tamm and Margolus–Levitin relations generate instances of infinite “time uncertainty” that is devoid of physical meaning. Only for quantum states with the maximal ℓ1 norm of energy coherence, C=1, the Mandelstam–Tamm and Margolus–Levitin relations avoid infinite “time uncertainty”, but they both reduce to a strict equality that expresses the Einstein–Planck relation between energy and frequency. The presented results elucidate the fact that the time in the Schrödinger equation is a scalar variable that commutes with the quantum Hamiltonian and is not subject to statistical variance.

arXiv:2401.07634•Symmetry•Jan 14, 2024•4 citations

Comment on "Energy-time uncertainty relation for driven quantum systems" and "Quantum Speed Limit for Non-Markovian Dynamics"

Manaka Okuyama, Takahashi Ryo, Masayuki Ohzeki

Deffner and Lutz [J. Phys. A 46, 335302 (2013) and Phys. Rev. Lett. 111, 010402 (2013).] extended the Mandelstam-Tamm bound and the Margolus-Levitin bound to time-dependent and non-Markovian systems, respectively. Although the derivation of the Mandelstam-Tamm bound is correct, we point out that thier analysis of the Margolus-Levitin bound is incorrect. The Margolus-Levitin bound has not yet been established in time-dependent quantum systems, except for the adiabatic case.

arXiv:1802.00995•Feb 3, 2018•0 citations

Time-symmetric quantum mechanics questioned and defended

Shaul Mukamel

The article by Yakir Aharonov, Sandu Popescu, and Jeff Tollaksen is stimulating and raises some interesting and profound issues regarding the foundations of quantum mechanics and quantum measurements. One point the authors make is that a measurement of spin component √2‾/2 of a spin-1⁄2 particle is unphysical and can be attributed only to errors in weak measurements performed on a collection of N spins. I offer a more mundane interpretation that does not require the introduction of any error or postselection concepts. The physical, textbook picture of spin-1⁄2 is a vector of length √S(S + 1) = √3‾/2 with some distribution of orientations (that is, polar coordinates θ and φ). A conventional single measurement of Sz can yield only one of the eigenvalues ±1⁄2. This may be interpreted in the classical vector model by envisioning that the spin lies on a cone with θ defined by cosθ = √3‾/3. The expectation value of Sx then vanishes due to the uniform distribution of φ. Having some control over φ can yield a finite value of Sx . Thus I would argue that only an expectation value greater than √3‾/2 is unphysical; a value of √2‾/2 is quite physical and can even be interpreted classically in terms of some distribution of φ and θ.I would phrase the important observation of Aharonov and coauthors in a different way. While spin-1⁄2 has a magnitude of √3‾/2, a fundamental limitation of conventional single-point quantum measurements is that they can yield only the values +1⁄2 and −1⁄2 and any expectation value must therefore lie between those two extremes. Classically, therefore, the spin may not be fully aligned along the z-axis with θ = 0. Such alignment is impossible since it would yield well-defined values of the three noncommuting variables Sz = √3‾/2 and Sx = Sy = 0. However, once multiple time measurements are performed, one can define a reduced distribution of some of the measurements that is conditional on the outcome in the other measurements; such a distribution can be interpreted in terms of Sz greater than 1⁄2 but less than or equal to √3‾/2. That interpretation does not violate any of quantum mechanics' fundamental rules, which do not usually consider such quantities.Rather than a new, time-symmetric formulation of quantum mechanics that involves pre- and postselection, one can simply treat the scheme of the authors' figure 1b as a three-point correlation function, whereas figures 2a and 2b show a four-point correlation function, each panel having its own set of conditional probabilities. Error, time reversal, and postselection need not be invoked. Instead, one may think in multiple dimensions and develop the right language for the interpretation of the observables.The combination of pre- and postselection is an attempt to create an artificial ensemble that reproduces the results of multiple-point measurements in a single one-point measurement. As shown by Aharonov and coauthors, that is possible by introducing errors. An alternative physical picture is obtained by retaining the multipoint analysis. Multidimensional thinking is well developed in coherent nonlinear spectroscopy, where a system of spins or optical chromophores are subjected to sequences of short impulsive pulses.11. R. R. Ernst G. Bodenhausen A. Wokaun Principles of Nuclear Magnetic Resonance in One and Two Dimensions Clarendon Press, New York (1978) . , 22. S. Mukamel Annual Review of Physical Chemistry 51 1 691 (2000). https://doi.org/10.1146/annurev.physchem.51.1.691 ; Physical Review A 61 2 21804 (2000). https://doi.org/10.1103/PhysRevA.61.021804 ; Principles of Nonlinear Optical Spectroscopy Oxford U. Press, New York (1995) . Similar ideas may be applied for the interpretation of multiple measurements. One can think of various types of n-point observables obtained by combining n − m perturbations and m measurements. The nonlinear n-point response functions in spectroscopy represent n − 1 impulsive perturbations followed by a single measurement. The objects Aharonov and colleagues considered correspond to n = m. Proper multiple-distribution functions could then be naturally used for the interpretation of such generalized measurements.REFERENCESSection:ChooseTop of pageREFERENCES <<1. R. R. Ernst G. Bodenhausen A. Wokaun Principles of Nuclear Magnetic Resonance in One and Two Dimensions Clarendon Press, New York (1978) . Google Scholar2. S. Mukamel Annual Review of Physical Chemistry 51 1 691 (2000). https://doi.org/10.1146/annurev.physchem.51.1.691 ; Google ScholarCrossref, ISI Physical Review A 61 2 21804 (2000). https://doi.org/10.1103/PhysRevA.61.021804 ; , Google ScholarCrossref, ISI Principles of Nonlinear Optical Spectroscopy Oxford U. Press, New York (1995) . , Google Scholar© 2011 American Institute of Physics.

Physics Today•May 1, 2011•3 citations

Operational Time, Inertia, and Phase Coherence

Hakan Balki

This work proposes an operational answer to the question of what time is: time is the process by which a physical system produces mutually distinguishable states, a quantity made precise in quantum mechanics through Quantum Fisher Information and the Mandelstam–Tamm bound. Building on this definition, the paper develops a framework in which inertia and gravitation are read as different derivatives of a single underlying quantity — the quantum phase. The framework points to a natural acceleration scale a⋆ = mc³/ℏ, constructible solely from m, c, and ℏ, and shows that for the electron this coincides algebraically with the acceleration in the Schwinger field. It further explores a phase-coherence factor C(a), its kinematic relation to a finite "phase-proper-time" window (via the Gudermann function), a possible Unruh-related spectral signature, and a scalar/vector decomposition of the four-force under an effective-momentum ansatz. The study positions itself explicitly not as a new theory of physics, but as a consistent rereading of standard physics and a research program that formulates the relevant open problems sharply. Throughout the text, results that are algebraically exact are transparently separated from those that hold open-problem / speculative status. Among the algebraically exact results are the four-force rereading, the recovery of Newtonian gravity from flowing space, the Schwinger-scale coincidence, and the kinematic identity for C(a); among the open problems are the physical mechanism behind the Schwinger coincidence, the status of C(a) as a genuine QFI modulation, and the derivation of the internal tick duration at the level of the QFI or the Wightman function. The framework is compatible with the relational-time and quantum-reference-frame programs (Page–Wootters, Rovelli) and shares conceptual ground with the flowing-space / river-model tradition (Painlevé–Gullstrand, Hamilton–Lisle), while preserving Lorentz invariance and treating the natural acceleration scale as a characteristic scale rather than a maximum-acceleration law.

•May 28, 2026•0 citations

Quantum decay and the Mandelstam-Tamm-energy inequality

Krishnendu Bhattacharyya

The Mandelstam-Tamm time-energy inequality is exploited to obtain a transparent expression of the lifetime-energy uncertainty relation for decaying quantum systems along with some useful features of the quantum non-decay probability.

Journal of Physics A Mathematical and General•Sep 11, 1983•214 citations

Proper Time for Spin 1/21/21/2 Particles

Shoju Kudaka, Shuichi Matsumoto

We find a quantum mechanical formulation of proper time for spin 1/2 particles within the framework of the Dirac theory. It is shown that the rate of proper time can be represented by an operator called the “tempo operator”, and that the proper time itself be given by the integral of the expectation value of the operator. The tempo operator has some terms involving the Pauli spin matrices, and the evolution of the proper time is influenced by the spin state via these terms. The relation between the tempo operator and the metric tensor is elucidated. 1

•Dec 30, 2006•0 citations
Georgiev's analysis of a freely precessing spin correctly emphasizes that the Mandelstam-Tamm quantity ΔT=ΔA^/∣d⟨A^⟩/dt∣ΔT=Δ\hat A/|d\langle\hat A\rangle/d t|ΔT=ΔA^/∣d⟨A^⟩/dt∣ is not the variance of a time operator. He concludes, however, that its divergence near the extrema of the clock signal is devoid of physical meaning and that ΔTΔTΔT does not disclose how well the system measures the passage of time. For the same projective σ^x\hatσ_xσ^x​ readout, we show that ΔTΔTΔT equals the inverse square root of the classical Fisher information in one binary outcome at regular operating points. Its divergence at submaximal-coherence extrema therefore identifies a loss of local sensitivity in the selected readout, not an infinite variance of physical time; a complementary σ^y\hatσ_yσ^y​ measurement remains informative. This interpretation also separates Georgiev's exactly known tick--tock period from the statistical precision with which a tick can be located. It preserves his warning against a time-operator interpretation while qualifying his stronger conclusion that the Mandelstam--Tamm scale lacks physical content.
This comment addresses whether the divergence of the Mandelstam–Tamm scale ΔT=ΔA/∣d⟨A⟩/dt∣\Delta T=\Delta A/|d\langle A\rangle/dt|ΔT=ΔA/∣d⟨A⟩/dt∣ makes it physically meaningless as a measure of clock performance. It revisits a freely precessing pure spin-1/21/21/2 with Hamiltonian H=ℏωσz/2H=\hbar\omega\sigma_z/2H=ℏωσz​/2, coherence C=2∣α1α2∣C=2|\alpha_1\alpha_2|C=2∣α1​α2​∣, and projective σx\sigma_xσx​ readout, distinguishing local timing sensitivity from a time-operator variance or a calibrated tick–tock interval.
Using the binary outcome probabilities, it derives the classical Fisher information Fx=ω2C2sin⁡2ϑ/(1−C2cos⁡2ϑ)F_x=\omega^2C^2\sin^2\vartheta/(1-C^2\cos^2\vartheta)Fx​=ω2C2sin2ϑ/(1−C2cos2ϑ) and establishes ΔT=1/Fx\Delta T=1/\sqrt{F_x}ΔT=1/Fx​​ at regular, locally identifiable operating points. The pure-state quantum Fisher information is FQ=4(ΔH)2/ℏ2=ω2C2F_Q=4(\Delta H)^2/\hbar^2=\omega^2C^2FQ​=4(ΔH)2/ℏ2=ω2C2, so the Mandelstam–Tamm bound becomes ΔTΔH=(ℏ/2)FQ/Fx≥ℏ/2\Delta T\Delta H=(\hbar/2)\sqrt{F_Q/F_x}\geq\hbar/2ΔTΔH=(ℏ/2)FQ​/Fx​​≥ℏ/2. For NNN independent preparations, locally unbiased estimators satisfy Var⁡(t^)≥ΔT2/N\operatorname{Var}(\hat t)\geq\Delta T^2/NVar(t^)≥ΔT2/N.
For 0<C<10<C<10<C<1, the divergence at signal extrema corresponds to Fx=0F_x=0Fx​=0: the readout loses first-order timing sensitivity although the state retains information. A complementary σy\sigma_yσy​ measurement attains FQF_QFQ​ there. The known half-period π/ω\pi/\omegaπ/ω therefore does not determine tick-localization precision. The discussion explicitly limits the estimator interpretation to regular local models: extrema require separate treatment, including the C=1C=1C=1 zero-over-zero case. Finite-sample effects, bias, periodic ambiguities, and phase knowledge needed for adaptive readout are not resolved; energy variance equals the quantum Fisher-information scale only for the pure-state setting considered.
The time–energy uncertainty relation in nonrelativistic quantum mechanics has been intensely debated with regard to its formal derivation, validity, and physical meaning. Here, we analyze two formal relations proposed by Mandelstam and Tamm and by Margolus and Levitin and evaluate their validity using a minimal quantum toy model composed of a single qubit inside an external magnetic field. We show that the ℓ1 norm of energy coherence C is invariant with respect to the unitary evolution of the quantum state. Thus, the ℓ1 norm of energy coherence C of an initial quantum state is useful for the classification of the ability of quantum observables to change in time or the ability of the quantum state to evolve into an orthogonal state. In the single-qubit toy model, for quantum states with the submaximal ℓ1 norm of energy coherence, C<1, the Mandelstam–Tamm and Margolus–Levitin relations generate instances of infinite “time uncertainty” that is devoid of physical meaning. Only for quantum states with the maximal ℓ1 norm of energy coherence, C=1, the Mandelstam–Tamm and Margolus–Levitin relations avoid infinite “time uncertainty”, but they both reduce to a strict equality that expresses the Einstein–Planck relation between energy and frequency. The presented results elucidate the fact that the time in the Schrödinger equation is a scalar variable that commutes with the quantum Hamiltonian and is not subject to statistical variance.
The article by Yakir Aharonov, Sandu Popescu, and Jeff Tollaksen is stimulating and raises some interesting and profound issues regarding the foundations of quantum mechanics and quantum measurements. One point the authors make is that a measurement of spin component √2‾/2 of a spin-1⁄2 particle is unphysical and can be attributed only to errors in weak measurements performed on a collection of N spins. I offer a more mundane interpretation that does not require the introduction of any error or postselection concepts. The physical, textbook picture of spin-1⁄2 is a vector of length √S(S + 1) = √3‾/2 with some distribution of orientations (that is, polar coordinates θ and φ). A conventional single measurement of Sz can yield only one of the eigenvalues ±1⁄2. This may be interpreted in the classical vector model by envisioning that the spin lies on a cone with θ defined by cosθ = √3‾/3. The expectation value of Sx then vanishes due to the uniform distribution of φ. Having some control over φ can yield a finite value of Sx . Thus I would argue that only an expectation value greater than √3‾/2 is unphysical; a value of √2‾/2 is quite physical and can even be interpreted classically in terms of some distribution of φ and θ.I would phrase the important observation of Aharonov and coauthors in a different way. While spin-1⁄2 has a magnitude of √3‾/2, a fundamental limitation of conventional single-point quantum measurements is that they can yield only the values +1⁄2 and −1⁄2 and any expectation value must therefore lie between those two extremes. Classically, therefore, the spin may not be fully aligned along the z-axis with θ = 0. Such alignment is impossible since it would yield well-defined values of the three noncommuting variables Sz = √3‾/2 and Sx = Sy = 0. However, once multiple time measurements are performed, one can define a reduced distribution of some of the measurements that is conditional on the outcome in the other measurements; such a distribution can be interpreted in terms of Sz greater than 1⁄2 but less than or equal to √3‾/2. That interpretation does not violate any of quantum mechanics' fundamental rules, which do not usually consider such quantities.Rather than a new, time-symmetric formulation of quantum mechanics that involves pre- and postselection, one can simply treat the scheme of the authors' figure 1b as a three-point correlation function, whereas figures 2a and 2b show a four-point correlation function, each panel having its own set of conditional probabilities. Error, time reversal, and postselection need not be invoked. Instead, one may think in multiple dimensions and develop the right language for the interpretation of the observables.The combination of pre- and postselection is an attempt to create an artificial ensemble that reproduces the results of multiple-point measurements in a single one-point measurement. As shown by Aharonov and coauthors, that is possible by introducing errors. An alternative physical picture is obtained by retaining the multipoint analysis. Multidimensional thinking is well developed in coherent nonlinear spectroscopy, where a system of spins or optical chromophores are subjected to sequences of short impulsive pulses.11. R. R. Ernst G. Bodenhausen A. Wokaun Principles of Nuclear Magnetic Resonance in One and Two Dimensions Clarendon Press, New York (1978) . , 22. S. Mukamel Annual Review of Physical Chemistry 51 1 691 (2000). https://doi.org/10.1146/annurev.physchem.51.1.691 ; Physical Review A 61 2 21804 (2000). https://doi.org/10.1103/PhysRevA.61.021804 ; Principles of Nonlinear Optical Spectroscopy Oxford U. Press, New York (1995) . Similar ideas may be applied for the interpretation of multiple measurements. One can think of various types of n-point observables obtained by combining n − m perturbations and m measurements. The nonlinear n-point response functions in spectroscopy represent n − 1 impulsive perturbations followed by a single measurement. The objects Aharonov and colleagues considered correspond to n = m. Proper multiple-distribution functions could then be naturally used for the interpretation of such generalized measurements.REFERENCESSection:ChooseTop of pageREFERENCES <<1. R. R. Ernst G. Bodenhausen A. Wokaun Principles of Nuclear Magnetic Resonance in One and Two Dimensions Clarendon Press, New York (1978) . Google Scholar2. S. Mukamel Annual Review of Physical Chemistry 51 1 691 (2000). https://doi.org/10.1146/annurev.physchem.51.1.691 ; Google ScholarCrossref, ISI Physical Review A 61 2 21804 (2000). https://doi.org/10.1103/PhysRevA.61.021804 ; , Google ScholarCrossref, ISI Principles of Nonlinear Optical Spectroscopy Oxford U. Press, New York (1995) . , Google Scholar© 2011 American Institute of Physics.
This work proposes an operational answer to the question of what time is: time is the process by which a physical system produces mutually distinguishable states, a quantity made precise in quantum mechanics through Quantum Fisher Information and the Mandelstam–Tamm bound. Building on this definition, the paper develops a framework in which inertia and gravitation are read as different derivatives of a single underlying quantity — the quantum phase. The framework points to a natural acceleration scale a⋆ = mc³/ℏ, constructible solely from m, c, and ℏ, and shows that for the electron this coincides algebraically with the acceleration in the Schwinger field. It further explores a phase-coherence factor C(a), its kinematic relation to a finite "phase-proper-time" window (via the Gudermann function), a possible Unruh-related spectral signature, and a scalar/vector decomposition of the four-force under an effective-momentum ansatz. The study positions itself explicitly not as a new theory of physics, but as a consistent rereading of standard physics and a research program that formulates the relevant open problems sharply. Throughout the text, results that are algebraically exact are transparently separated from those that hold open-problem / speculative status. Among the algebraically exact results are the four-force rereading, the recovery of Newtonian gravity from flowing space, the Schwinger-scale coincidence, and the kinematic identity for C(a); among the open problems are the physical mechanism behind the Schwinger coincidence, the status of C(a) as a genuine QFI modulation, and the derivation of the internal tick duration at the level of the QFI or the Wightman function. The framework is compatible with the relational-time and quantum-reference-frame programs (Page–Wootters, Rovelli) and shares conceptual ground with the flowing-space / river-model tradition (Painlevé–Gullstrand, Hamilton–Lisle), while preserving Lorentz invariance and treating the natural acceleration scale as a characteristic scale rather than a maximum-acceleration law.
We find a quantum mechanical formulation of proper time for spin 1/2 particles within the framework of the Dirac theory. It is shown that the rate of proper time can be represented by an operator called the “tempo operator”, and that the proper time itself be given by the integral of the expectation value of the operator. The tempo operator has some terms involving the Pauli spin matrices, and the evolution of the proper time is influenced by the spin state via these terms. The relation between the tempo operator and the metric tensor is elucidated. 1