arXiv:2610.22023
Loss-independent time-delay estimation via Hong-Ou-Mandel photon bunching detection
Julián Defant, Agustina G. Magnoni, Miguel A. Larotonda, Laura T. Knoll
Abstract
In this work we study the application of two-photon correlated quantum states for high-precision time estimation. To achieve this, photon pairs were fed into a Hong-Ou-Mandel polarization interferometer to generate N00N entangled states with $N = 2$. Two- and four-detector schemes were considered, and the achievable time estimation precision of each was studied, with particular emphasis on the system's Fisher information in each case. Our results reveal that using a four-detector scheme, enabling the measurement of both coincidence and photon-bunching terms, achieves the maximum precision given by the quantum Fisher information, without the need of characterizing system losses. We also show that correlations between repetitions arise due to systematic errors, limiting the precision enhancement that can be obtained by increasing the number of repetitions. Taking these correlations into account, we show that the four-detector scheme outperforms the two-detector scheme in the precision of time-delay estimation. With the experimentally determined calibration uncertainties, the four-detector scheme improves the dispersion by a factor of 2 for the repetitions performed, reaching up to a factor of 4 as both schemes approach their systematic floors.
AI Summary
The paper asks whether detecting photon bunching as well as coincidences in Hong–Ou–Mandel (HOM) interferometry can remove loss-calibration dependence from time-delay estimation. It compares two non-number-resolving detectors, one per output, with four detectors that spatially multiplex each output to identify bunched pairs. Outcome probabilities, maximum-likelihood estimators and Fisher information are analyzed, including shared calibration uncertainties across repeated measurements. Conditioning on detected pairs makes the four-detector estimator independent of the modeled common photon-loss probability. For perfect visibility and vanishing delay, its Fisher information approaches $F_Q=8/t_c^2$, where $t_c$ is the coherence time. This is information per detected pair, not per incident pair: losses still reduce the detection rate. Near optimal operating points, both schemes extract essentially the same information per detected pair; their precision difference arises from loss-calibration uncertainty. An SPDC polarization-HOM experiment measures a piezoelectric displacement over $3.7\times10^3$ repetitions, obtaining $(6.418\pm0.018)\,\mu\mathrm{m}$ with four detectors versus $(6.386\pm0.037)\,\mu\mathrm{m}$ with two. Propagating calibration uncertainties gives projected systematic floors of 26 as and 110 as, respectively. Added-loss tests leave the four-detector estimate consistent without recalibration, whereas the two-detector estimate requires updated loss calibration. Residual distinguishability limits reconstructed Fisher information to about 80% of the ideal QFI. This reconstruction uses multinomial resampling of measured probabilities because alignment instability prevented repeated full scans. Visibility calibration still imposes a precision floor, and the projected fourfold floor improvement is not reached experimentally.
Central claim may not hold: The abstract's QFI-saturation claim omits the perfect-visibility and zero-delay-limit conditions required by the theoretical result. The claimed loss-independent Fisher information is conditional on detected pairs and does not establish loss-independent precision per incident pair or at fixed acquisition time. The implemented fiber-beamsplitter/APD measurement accepts bunched and cross-output pairs with different probabilities, but the paper uses ideal photon-number-outcome probabilities without specifying the acceptance correction and statistical model needed to justify its experimental Fisher-information analysis.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 11 pages, 5 figures