arXiv:2610.21608
Driving the cooling process of a quantum system via classical noise
B. Militello, A. Napoli
Abstract
It is known that under particular hypotheses anomalous thermalization processes can occur, such as the Mpemba effect, consisting in a faster cooling down when the system is prepared in a hotter initial condition, thus making convenient to warm up the system before the freezing process in order to make it freeze in a shorter time. It is shown here that the action of a Markovian classical noise during the freezing process can accelerate the approach to the zero-temperature thermal state. This prediction is counterintuitive, especially after observing that a classical noise can be considered equivalent to the action of an infinite-temperature reservoir, since both drive the system toward the same state. These facts lead to the statement that warming up the system during the contact with a low-temperature reservoir can accelerate the cooling process.
AI Summary
The paper asks whether adding classical Markovian noise during relaxation to a zero-temperature bath can accelerate cooling without changing the ground-state steady state. It considers finite-dimensional GKLS dynamics with downward quantum jumps and Hermitian classical-noise operators that act only within the excited-state subspace. Unlike comparisons between different initial temperatures, the proposed protocol modifies the relaxation generator during cooling. A strong-noise perturbative analysis shows that rapid mixing equalizes the excited-state populations. For an $N$-level system with direct decay rates $\gamma_{j0}$ to the ground state, the resulting effective loss rate from the excited subspace is $\Gamma_{\mathrm{eff}}=(N-1)^{-1}\sum_{j=1}^{N-1}\gamma_{j0}$. After the fast mixing transient, the ground-state population therefore approaches unity approximately as $p_g(t)=1-p_e(0)e^{-\Gamma_{\mathrm{eff}}t}$. This redistribution can accelerate or slow relaxation, depending on the original decay bottlenecks. Numerical simulations of three-level systems, initially in Gibbs states, track trace distance to the ground state. They illustrate acceleration for unequal direct decay rates and for a cascade with slow upper-to-lower relaxation, but slowing for the opposite cascade hierarchy. Equal direct decay rates leave cooling unchanged. Visible effects also occur outside the strong-noise limit; examples use $\eta_{12}/\omega_1=0.1$ while a quantum decay rate exceeds that value. The analytical result assumes sufficiently strong classical noise and mixing confined to the excited subspace. Preserving the zero-temperature steady state requires that the added noise not couple to the ground state. The numerical evidence is restricted to three-level examples; acceleration is not universal.
Error found: The claimed two-dimensional stationary kernel requires stronger assumptions than the stated absence of common excited-state eigenvectors, because multiple invariant excited-state blocks can satisfy that condition while supporting additional stationary projectors. The displayed slow right eigenoperator lacks a factor of 1/(N−1) on the excited-state projector, making the ensuing approximate density operator non-trace-preserving for N greater than two. The initial definition of epsilon has the opposite sign from that required by the restricted generator and the later positive decay-rate calculation.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 6 pages, 3 figures