arXiv:2610.20487
Demonstration of a mobile ion-trap quantum device
Sara Alfaro, Dipesh Bhanushali, Sankarshan Choudapurkar, Ashwin Bhartia, Thomas Lafenthaler, Tommaso Faorlin, Yannick Weiser, Lorenz Panzl, Thomas Monz, Rainer Blatt, Giovanni Cerchiari
Abstract
Trapped-ion devices are being investigated for transportable applications, including the transfer of exotic charged particles between laboratories and the development of portable quantum technologies. To date, ion transport has been demonstrated only in magnetic (Penning) traps, whereas radiofrequency (Paul) traps are the predominant platform in quantum science. Here, we report the first transport of a few thousand ions confined in a linear Paul trap over distances of several kilometers, with transport durations of 15 and 45 min. These results establish a foundation for mobile trapped-ion quantum devices capable of operating while in motion and may enable the transport of exotic ions in Paul traps between experimental facilities.
AI Summary
Can ions remain confined in a radiofrequency Paul trap during vehicle transport? This paper reports transport of a few thousand positive ions in a linear Paul trap over road distances of 18.6 and 63.4 km. The apparatus combines an ultrahigh-vacuum chamber, RF and DC supplies, pumps, and battery-backed power in a transportable rack. Ions are generated by laser ablation of an endcap electrode and assigned predominantly to singly charged carbon from their approximate mass-to-charge ratio, $12\,\mathrm{u}/e$. After loading in a stationary van, they remain confined during driving and are destructively detected after parking by extraction onto a microchannel plate. The measured populations are approximately $3.82\times10^3$ after 15 minutes and $1.17\times10^3$ after 45 minutes. Ion counts combine resolved detector events with intensity-based estimates where signals overlap; pileup calibration contributes a substantial systematic uncertainty, about 33% for the 15-minute measurement. An exponential fit to the transport measurements gives a storage lifetime of $1.52(71)\times10^3$ s, statistically consistent with the stationary-laboratory value of $2.6(5)\times10^3$ s. The transport evidence comprises two runs with fluctuating loading yields, rather than continuous measurements of the trapped population during motion. The demonstrated capability is ion retention, not quantum-state preservation or quantum operation during transit. Laser cooling and coherent control in motion are explicitly identified as next steps. Optical access and an external-ion injection interface are incorporated, but beamline loading and transport of exotic species are not demonstrated.
Error found: The main text specifies a 600 V RF amplitude while the Supplementary Material specifies 600 V peak-to-peak, leaving a factor-of-two ambiguity in the operating voltage. The printed systematic uncertainty of 3.9 × 10^3 ions on the 45-minute count is inconsistent with the substantially smaller reported transport-lifetime uncertainty unless a typographical error or an unreported uncertainty treatment is involved.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 7 pages, 4 figures