arXiv:2610.20132
A low-cost compact muon detector for millikelvin operation
Tengiz Ibrayev, Danish Khan, Alex Herscovics, Komal Kataruka, Matilda Lawton, Sandhya Sharma, Steven Waddy, Laura Manenti
Abstract
Ionizing radiation produces correlated errors in superconducting qubits, posing some challenges to quantum error correction. In addition, it causes background events in other superconducting cryogenic devices, such as kinetic inductance detectors and superconducting nanowire single-photon detectors. Cosmic muons are a component of this background that can only be partly shielded against at ground level, but can be tagged by an independent detector inside the cryostat, so that the affected data can be vetoed, or the muon tags incorporated into error correction. We present a low-cost, compact muon detector consisting of two plastic scintillator modules, each read out by a silicon photomultiplier (SiPM), operated in coincidence. We characterize the SiPMs from room temperature down to 10 mK, including the breakdown and upper-limit voltages that define the operating bias range. Operated as a muon counter, the detector measures a coincidence rate that, as expected, is independent of temperature within uncertainties and agrees with analytical and Monte Carlo predictions. Below approximately 8 K, each muon event produces two pulses, one narrow and one broad, an effect that, to our knowledge, has not been reported before. Coincidences with an independent muon detector outside the cryostat confirm that muons are still counted reliably in this regime. By studying the appearance of double pulses as a function of temperature and magnetic field up to 4.5 T, we find a behavior consistent with the phase diagram of a type-II superconductor. This links the double pulses to a superconducting material in the SiPM, likely an adhesion layer or diffusion barrier introduced during manufacturing. The mechanism by which the superconducting state produces the second pulse is not yet understood.
AI Summary
Cosmic muons can generate correlated errors in superconducting qubits and backgrounds in other cryogenic superconducting devices. This paper investigates whether a compact scintillator–silicon-photomultiplier (SiPM) coincidence detector can reliably tag muons inside a dilution refrigerator. The detector uses two $14\times8\times8\,\mathrm{mm}^3$ plastic scintillators coupled to commercial SiPMs; the scintillators, sensors and PCBs together cost under USD 100. Measurements from room temperature to approximately $10\,\mathrm{mK}$ characterize the breakdown voltage and operational upper bias limit. Both vary non-monotonically at low temperature, defining a temperature-dependent operating window. Muon coincidence rates measured in two dilution refrigerators remain within 15% of their mean across temperatures and agree with analytical acceptance calculations and Geant4 simulations, including measured building attenuation. The analytical prediction is $8.1\pm1.4$ events per hour. Below approximately $8\,\mathrm{K}$, the sensor response splits into prompt narrow and delayed broad pulses. Temperature and magnetic-field scans up to $4.5\,\mathrm{T}$ show that suppressing this splitting follows a superconducting-like phase boundary, with fitted $T_c=8.05\pm0.08\,\mathrm{K}$ and extrapolated $B_{c2}(0)=8.1\pm0.5\,\mathrm{T}$. A forward-voltage transition near $8.08\,\mathrm{K}$ provides additional evidence for superconducting material within the SiPM. Timing remains usable: 152 fourfold coincidences with external detectors confirm muon detection despite splitting. The responsible material and pulse-generation mechanism remain unidentified, and extracting photon counts from split waveforms is unresolved. Operation alongside a qubit array and use of tags in error correction are left to future work.
ChatGPT and Claude Code were used to correct grammar and typographical errors in the manuscript and to assist in searching the literature.
Error found: The Monte Carlo rate comparison uses room-temperature photon-detection efficiency and a fixed amplitude-per-photon conversion that are not validated for the millikelvin double-pulse response, so its quantitative acceptance prediction is conditional on those response assumptions.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.