arXiv:2610.17228
Observation of Photon Bunching in Broadband Multimode Thermal Light Enabled by Temporal Imaging
Filip Sośnicki, Michał Mikołajczyk, Sanjay Kapoor, Dmitri B. Horoshko, Mikhail I. Kolobov, Michał Karpiński
Abstract
Photons emitted by incoherent sources exhibit temporal bunching, a fundamental manifestation of Bose-Einstein statistics first observed by Hanbury Brown and Twiss (HBT). While intensity correlation measurements originated in astronomy and are now central across quantum technologies, biophysics, and spectroscopy, observing temporal bunching in broadband thermal light remains limited by detector temporal resolution. Conventional approaches - such as streak cameras or optical upconversion - introduce severe trade-offs in efficiency, bandwidth, or setup versatility. Here, we propose and demonstrate a third route: pre-detection temporal magnification of the optical field prior to measuring its intensity autocorrelation function in a conventional HBT setup. Using an electro-optic time lens with a temporal magnification of 660, we resolve the temporal intensity autocorrelation of broadband thermal light generated via non-degenerate spontaneous parametric down-conversion with a bandwidth of 250 GHz. This enables direct observation of thermal photon bunching on sub-3.5 picosecond timescales without narrow spectral filtering, establishing pre-detection temporal imaging as a general platform for broadband statistical optics, with applications spanning ultrafast quantum optics, biophysical imaging, and potentially stellar intensity interferometry.
AI Summary
Broadband thermal-light bunching is difficult to resolve when the coherence time is shorter than detector timing resolution. This paper investigates whether temporal magnification before a conventional Hanbury Brown–Twiss measurement can recover time-resolved bunching without narrowband filtering to match the detectors. The experiment uses one arm of pulsed, non-degenerate SPDC as a thermal source, with the idler discarded. Adjusting the pump bandwidth changes the estimated Schmidt number from $K=1.02$ to $1.68$. An electro-optic time lens between two dispersive elements provides $660\times$ temporal magnification at an $80$ MHz repetition rate, stretching approximately $3$ ps pulses to about $2$ ns. The independently measured temporal-imaging resolution is $3.4$ ps; detection uses superconducting nanowire detectors with approximately $30$ ps timing resolution. For signal bandwidths reaching $246.5$ GHz, zero-delay peak-height ratios give $g^{(2)}(0)=2.08\pm0.04$ at $K=1.68$ and $2.04\pm0.04$ at $K=1.02$. Across the measured mode-number range, time-resolved values remain near two, whereas pulse-integrated correlations follow $1+1/K$. Coincidence histograms are fitted with Gaussians and normalized using the average heights of peaks from different, uncorrelated pulses. The demonstrated implementation magnifies synchronized pulses within each repetition period, rather than stretching the entire time axis. Schmidt-number estimates and inferred temporal profiles assume a flat joint spectral phase. Spectral filtering is still used to suppress idler leakage and phase-matching sidelobes. Applications to continuous broadband sources, fluorescence, and stellar intensity interferometry are proposed rather than demonstrated.
Error found: The displayed coincidence histograms retain the pulsed intensity envelope and therefore are not the normalized delay-dependent g^(2)(τ), although their central-to-side peak-height ratio can measure zero-delay bunching. Fitting the multimode central coincidence peak with a single Gaussian introduces an unquantified model-dependent uncertainty into the reported zero-delay bunching values. The stated coherence-time extraction incorrectly applies a Gaussian product-width relation to the complete central coincidence peak rather than to its bunching excess above the accidental envelope.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 9 pages + 3 supplement, 4 + figures