arXiv:2610.10294
Sub-shot-noise mid-infrared photothermal measurements using twin beams
Kazuki Hashimoto, Takuro Ideguchi
Abstract
Mid-infrared photothermal (MIP) measurement probes refractive-index changes induced by mid-infrared (MIR) absorption using visible or near-infrared light and has recently emerged as a powerful modality for MIR spectro-imaging in the life sciences. Reducing measurement noise allows the probe power to be lowered without compromising the signal-to-noise ratio (SNR), thereby mitigating the risk of sample damage. However, even in the absence of classical noise, the SNR of conventional MIP measurements using a classical coherent probe is fundamentally limited by shot noise. Here, we demonstrate sub-shot-noise MIP measurement using twin beams generated through seeded optical parametric amplification. Balanced detection of the twin beams suppresses the noise by more than 5 dB below the shot-noise level established using a coherent beam. As a proof-of-principle demonstration, we measure the MIP signal from liquid water using balanced twin-beam detection and achieve an SNR enhancement of more than 2 dB over the balanced coherent-beam detection.
AI Summary
Mid-infrared photothermal (MIP) sensing detects absorption-induced refractive-index changes with a shorter-wavelength probe. This paper tests whether intensity-correlated twin beams can reduce its measurement noise below the coherent-state shot-noise level. The experiment generates pulsed telecom-band twin beams through seeded optical parametric amplification in a PPLN waveguide. One beam probes a water sample heated by a 4.64-µm quantum-cascade laser modulated at 2 MHz; the other provides a reference for balanced detection. A Fourier-plane aperture converts thermal-lens-induced spatial changes into intensity modulation. Standalone twin-beam characterization gives a minimum intensity-difference noise reduction of 5.7 dB after electronic-noise subtraction. In the MIP configuration, the reported noise reduction is 2.4 dB and RF-power SNR enhancement is 2.3 dB relative to balanced coherent-beam detection. Coherent-probe measurements establish the reference through linear noise-power and quadratic signal-power scaling with photon number. The demonstration measures water at one pump wavelength, rather than acquiring an absorption spectrum or microscopic image. Optical losses, including the detection aperture, degrade the quantum correlations and constrain signal optimization. Crucially, balanced detection adds a reference-arm shot-noise penalty: at equal sample-probe photon number, more than 3 dB suppression is needed to outperform single-port coherent detection, which the MIP demonstration does not establish. Spectroscopic scans, microscopic samples, lower modulation frequencies, and shorter probe wavelengths for biological imaging remain proposed extensions.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.