arXiv:2610.07806 · Physical Review Research
Quantum telescopy with realistic anti-correlated optical fields as references
Xuan Tang, Z. Y. Ou
Abstract
Quantum telescopy, proposed by Grottesman et al., uses spatially entangled single-photon states to modify HBT stellar interferometry, potentially surpassing Michelson interferometry in resolution without baseline limits. However, finite source bandwidth, non-unit efficiency, detector response times, and celestial light bandwidth all affect its effectiveness. In this work, we consider a spatially entangled singe-photon state generated by beam-splitting a practical anti-bunched photon source from resonance fluorescence, which is a common method of generating single-photon states, and evaluate the signal level in quantum telescopy with inclusion of imperfection of detection system and finite bandwidth of celestial light. Here, given the incoming light, we optimize the parameters of the anti-bunched photon source and the detector system for the best signal-to-noise ratio (SNR), which can match that of the Michelson method in the ideal case but is always smaller in the realistic case. Alternatively, weak coherent states from heavily attenuated lasers can replace the entangled single-photon state but suffer low signal level, similar to HBT method. We find that the SNR with a realistic anti-bunched source for producing the reference fields can still beat the SNR of the coherent state scheme in the weak incoming field limit. The optimized parameters for the anti-bunched source and detection system will be a guide for future experimental endeavor.
AI Summary
Quantum telescopy uses spatially entangled single-photon references to recover astronomical spatial coherence without directly combining light from distant telescopes. This paper asks how finite-duration antibunching, source brightness, coincidence timing and reference loss affect its signal-to-noise ratio (SNR), compared with Michelson interferometry and coherent-reference intensity interferometry. The analysis models reference fields obtained by splitting continuous-wave resonance fluorescence from a driven two-level emitter. It integrates intensity correlations over a coincidence window $T_R$, assumes Poissonian coincidence-count noise, and optimizes the emitter decay parameter $\beta$ and Rabi frequency $\Omega$. For weak thermal input with $N_R=IT_R\ll1$ and $T_R\ll T_c$, a short-delay expansion gives $\Omega/\beta=2$, $\beta T_R=(3N_R/2)^{1/3}$, and $\mathrm{SNR}_{\mathrm{RFl}}/\mathrm{SNR}_{\mathrm{MI}}=(2/3)^{5/6}N_R^{1/6}$, where $\mathrm{SNR}_{\mathrm{MI}}=\sqrt{2IT}$. Numerical optimization extends the calculation beyond this asymptotic regime. The optimized fluorescence reference outperforms the coherent-reference scheme by approximately $0.5N_R^{-1/3}$, but remains below Michelson SNR for weak input; the advantage over coherent references disappears toward $N_R\sim1$. Reference transmission $1-L$ adds an optimized SNR factor $(1-L)^{1/3}$. A phenomenological source with flatter short-delay antibunching, $g_2(\tau)\propto\tau^M$, yields relative SNR scaling as $N_R^{1/[2(M+1)]}$, suggesting a source-engineering target rather than providing a concrete construction. The treatment assumes matched spatial modes and a coincidence window shorter than the celestial coherence time. Dark counts and detector inefficiency are excluded from the calculation; their additional penalties are discussed. Ideal Michelson-level performance relies on an idealized flat-bottom correlation function unavailable from the resonance-fluorescence source considered.
Error found: Detector quantum efficiency is not included in the SNR calculation, despite the abstract's framing of detection imperfections; the conclusion explicitly acknowledges this omission. The reported source optimization is conditional on a fixed coincidence window, rather than a joint optimization of the source and detector window. The generalized optimized-SNR formula incorrectly contains (CN_R/2)^[1/(2(M+1))] instead of (2N_R/C)^[1/(2(M+1))], although the separately derived resonance-fluorescence scaling remains correct. The Sirius example overestimates the coherence time for a 0.5 nm bandwidth at 555 nm by approximately tenfold under the paper's inverse-frequency-bandwidth convention, making its quoted 4 ps coincidence window inconsistent with the assumed time-resolution regime.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 10 pages, 6 figures