arXiv:2610.07680
Spectroscopy using dipole-phonon quantum logic
Lu Qi, Evan C. Reed, Duanyang Wang, Boyan Yu, Kenneth R. Brown
Abstract
Dipole-phonon quantum logic (DPQL) offers novel approaches for state preparation, measurement, and control of quantum information in molecular ion qubits. Here we report the first experimental demonstration of DPQL as a spectroscopic tool using the shared motional mode of a CaO$^+$-Ca$^+$ ion chain to measure the frequency splitting of the ground $Ω$-doublet of CaO$^+$. By comparing the dipole-phonon signal across three trap-frequency ramp ranges, we determine the splitting to be $ω_{mol}=2π\times454\pm1$ kHz and place a lower bound on the effective dipole-phonon coupling. The rate of observation is limited by the low thermal population in the molecular ground rotational state.
AI Summary
Dipole-phonon quantum logic (DPQL) couples opposite-parity molecular states directly to trapped-ion motion, enabling readout through a co-trapped atomic ion. This paper tests DPQL as a spectroscopic tool for the ground rotational-state $\Omega$-doublet of CaO$^+$ using a CaO$^+$–Ca$^+$ chain. The protocol cools the shared axial mode near its ground state, sweeps its frequency through a possible molecular resonance, and detects emitted phonons through Ca$^+$ sideband shelving. A return sweep resets the molecular state for repeated interrogation. Three overlapping sweep ranges locate the resonance through their signal/null pattern; CaOH$^+$, which lacks the required doublet, supplies a molecular control. The middle range shows clustered shelving events absent at comparable levels in the controls. A tail-counting analysis finds 119 high-count windows against 32 expected from background, giving a nominal $11.7\sigma$ significance under a Poisson model. Joint modeling yields $\omega_{\mathrm{mol}}/2\pi=454\pm1$ kHz and an effective coupling corresponding to a dipole lower bound of approximately $2.5$ Debye, rather than a direct permanent-dipole measurement. Room-temperature ground-state population limits the event rate: 38 candidate bursts occur in 13.07 hours. Their characteristic detected duration is $1.87^{+0.50}_{-0.34}$ s, versus 4.92 s in the processed blackbody model. Shelving efficiency is also below prediction. Unmodeled trap imperfections and a nonideal radiation environment are possible explanations. The joint frequency–coupling score has uncalibrated confidence coverage, and the population fit treats correlated windows as independent.
Central claim may not hold: The reported 454 ± 1 kHz frequency uncertainty comes from an explicitly uncalibrated score whose off-resonant penalties omit the observed counts, so its statistical coverage is not established. The shelving-distribution fit treats windows as independent despite bursts spanning multiple windows, leaving the fit uncertainty propagated into the frequency–coupling constraint without a demonstrated correction for temporal dependence.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 13 pages, 7 figures