Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2610.05667

Constraints on the Origin of Universal $1/f^2$ Photon-Count Spectra at Baseband

Malvin Carl Teich, Steven B. Lowen

physics.opticsquant-phSubmitted Oct 5, 2026• Announced Oct 6, 2026
arXivHTMLPDF

Abstract

A series of 11.6-d-duration photon-counting experiments, employing a broad variety of light sources with different statistical properties and optical spectra, were carried out over a 1.5-yr period. All of the photon-count spectra at baseband followed a common $1/f^2$ form over the frequency range $1 \times 10^{-6} \leqslant f \leqslant 5 \times 10^{-4}$ Hz, corresponding to a timescale range $33$ min $ \leqslant T_f \leqslant 11.6$ d, where $T_f \equiv 1/f$. The lower and upper timescale limits were established by the photodetector noise floor and the duration of the individual experiments, respectively. Unlike ordinary Brownian motion, all of the measured photon-count sample paths exhibited irregular long-timescale fluctuations, with durations ranging from hours to days. It has been established that the photon-count spectra cannot plausibly be ascribed to fluctuations of the current, voltage, or temperature of the source or the detector, nor to technical sources of noise associated with the optical system or local environment. Although the physical origin of the photon-count fluctuations remains unresolved, several heterodox hypotheses are set forth. From a statistical point-of-view, the photon counts appear to follow a doubly stochastic Poisson process with a slowly varying random intensity. Analogous experiments that rely on ionizing radiation and direct-conversion solid-state radiation detectors are proposed.

AI Summary

The paper investigates the origin of approximately $1/f^2$ photon-count spectra at very low frequencies, reviewing previously reported measurements and examining possible explanations. Experiments conducted over 1.5 years used LEDs, superluminescent diodes, laser diodes, incandescent sources, and tritium-driven phosphor luminescence, with SPAD and PMT detection. Most records lasted 11.6 days, with counts collected in 5-s windows at roughly $2\times10^5\,\mathrm{s}^{-1}$. Across these sources, normalized periodograms follow approximately $1/f^2$ over $10^{-6}$–$5\times10^{-4}\,\mathrm{Hz}$, corresponding to 33 minutes–11.6 days. Wavelet variances show corresponding quadratic scaling. Simultaneous split-beam measurements exhibit correlated slow fluctuations in different detectors; shuffling count order removes the spectral structure while preserving count histograms. These observations motivate a Cox-process description: conditionally Poisson counts driven by a slowly fluctuating random intensity, yielding excess count variance and an intensity spectrum above the white shot-noise floor. Comparisons with electrical and temperature records, dark-count measurements, detector technologies, and operating conditions are used to argue against conventional source, detector, optical, and environmental explanations. Betaluminescence establishes that an applied electrical drive is unnecessary. Several technical-noise exclusions rely on consistency across configurations rather than direct quantitative bounds. The physical mechanism remains unresolved. Integrated forcing, mean-reverting diffusion, and intermittent diffusion are discussed as phenomenological possibilities, without identifying a driver. The accessible band is limited by record duration and noise, leaving a possible low-frequency rollover untested. Proposed simultaneous independent-source and direct ionizing-radiation measurements would help distinguish source-specific fluctuations from a common external influence.

Little sign of AI-generated textOverclaimsIncrementalUnclear noveltyPossible error

Central claim may not hold: Betaluminescence without electrical drive rules out electrical fluctuations as a necessary common cause, not as a cause of the fluctuations measured in electrically driven sources. The paper excludes thermal contributions without supplying temperature-to-count transfer functions or quantitative bounds on the resulting photon-count noise. Recurring 1/f² slopes across different configurations do not establish the paper's broad exclusions of optical, environmental, mechanical, and source-package noise. Tritium's stated half-life predicts a 0.1785% intensity decrease over 11.6 days whose contribution to the betaluminescence periodogram is not quantitatively addressed, although its dominance is not established.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
19 pages, 12 figures, 1 animated video in Ancillary Directory

Related papers

Photon-count fluctuations exhibit inverse-square baseband spectral behavior that extends to <1μHz

Nishant Mohan, Steven Bradley Lowen, Malvin Carl Teich

The authors demonstrate that a broad variety of light sources with markedly different optical spectra all exhibit slow photon-count fluctuations at baseband that display inverse-square spectral behavior at frequencies that extend to 1 $\ensuremath{\mu}$Hz. These fluctuations are unexpected and may appear in experimental schemes from optical coherence tomography to gravitational-wave detection

arXiv:1911.08466•Physical Review Research•Feb 19, 2020•5 citations

Distinguishing photon-count fluctuation characteristics of classical and quantum light sources using non-Markovian processes

Lian Seng Tey, Sithi Vinayakam Muniandy, Wu Yi Chong

Understanding photon-count dynamics is crucial for applications such as quantum random number generators and quantum key distributions, where random and memoryless photon-count arrival processes are essential for performance and security. We investigated the fluctuation dynamics of aggregated photon-count time series for two distinct light sources: a 780-nm laser diode and a spontaneous parametric down-conversion source, using detrended fluctuation analysis (DFA) and the index of dispersion for intervals (IDI). Despite the degradation of photon statistics to Poissonian due to optical losses and detector inefficiencies, our analysis reveals significant long-range dependence at large timescales. The DFA scaling exponents α[over ¯]>0.75 and IDI values c_{k}^{2}>1 at high mean photon count and large aggregation timescales indicate photon-count fluctuations deviated from Poisson model. Our findings underscore the necessity of models beyond Poisson statistics to accurately describe the photon-count dynamics over extended timescales.

Physical review. E•Apr 28, 2025•7 citations

Theory of periodic sampling of photon-counting distributions

Eric Jakeman, Edward R. Pike

The statistical accuracy with which moments of the intensity-fluctuation distributions of optical fields can be determined, by photon-counting experiments of finite duration, is calculated.

Journal of Physics A Mathematical and General•Nov 1, 1968•17 citations

Photocounting distributions for exponentially decaying sources

Malvin Carl Teich, HOWARD C. CARD

Exact photocounting distributions are obtained for a pulse of light whose intensity is exponentially decaying in time, when the underlying photon statistics are Poisson. It is assumed that the starting time for the sampling interval (which is of arbitrary duration) is uniformly distributed. The probability of registering n counts in the fixed time T is given in terms of the incomplete gamma function for n >/= 1 and in terms of the exponential integral for n = 0. Simple closed-form expressions are obtained for the count mean and variance. The results are expected to be of interest in certain studies involving spontaneous emission, radiation damage in solids, and nuclear counting. They will also be useful in neurobiology and psychophysics, since habituation and sensitization processes may sometimes be characterized by the same stochastic model.

Optics Letters•May 1, 1979•14 citations

Influence of light source and detector’s imperfections on the photon counting statistics

Aleksei Reutov, Сыч Денис Васильевич

Abstract Photon counting provides a valuable tool for measuring quantum properties of light. Unavoidable imperfections of photon detectors lead to discrepancies between the statistics of photons and statistics of photon counts. Here we consider dead-time corrections and influence of intensity fluctuations for simulated Poissonian statistics of photo counts for the pulsed or continuous wave coherent light sources. We analyse dependence between the statistical moments of corrected distribution and the mean photon number, dead-time, and level of intensity fluctuations.

Journal of Physics Conference Series•Jul 1, 2021•0 citations

Analysis of Light Fluctuations from Photon Counting Statistics*

Gabriel Bédard

It is well known that photoelectric measurements yield information about the statistical behavior of fluctuating light beams. The probability of n photoelectrons being ejected, in a fixed time interval, from the photosensitive surface of the photoelectric detector, upon which the light beam is normally incident, is a linear (Poisson) transform of the probability density for the intensity of the beam. With the help of some plausible assumptions, the present analysis provides solutions to the problem of inverting the Poisson transform, thus determining the probability density for the intensity from experimentally obtained photocounting distributions. The effectiveness of the method is demonstrated by an actual inversion of a typical experimental counting distribution. The technique is of particular interest in connection with efforts to understand the statistical behavior of optical fields, especially of laser fields.

Journal of the Optical Society of America•Oct 1, 1967•32 citations
Constraints on the Origin of Universal 1/f21/f^21/f2 Photon-Count Spectra at Baseband
A series of 11.6-d-duration photon-counting experiments, employing a broad variety of light sources with different statistical properties and optical spectra, were carried out over a 1.5-yr period. All of the photon-count spectra at baseband followed a common 1/f21/f^21/f2 form over the frequency range 1×10−6⩽f⩽5×10−41 \times 10^{-6} \leqslant f \leqslant 5 \times 10^{-4}1×10−6⩽f⩽5×10−4 Hz, corresponding to a timescale range 333333 min ⩽Tf⩽11.6 \leqslant T_f \leqslant 11.6⩽Tf​⩽11.6 d, where Tf≡1/fT_f \equiv 1/fTf​≡1/f. The lower and upper timescale limits were established by the photodetector noise floor and the duration of the individual experiments, respectively. Unlike ordinary Brownian motion, all of the measured photon-count sample paths exhibited irregular long-timescale fluctuations, with durations ranging from hours to days. It has been established that the photon-count spectra cannot plausibly be ascribed to fluctuations of the current, voltage, or temperature of the source or the detector, nor to technical sources of noise associated with the optical system or local environment. Although the physical origin of the photon-count fluctuations remains unresolved, several heterodox hypotheses are set forth. From a statistical point-of-view, the photon counts appear to follow a doubly stochastic Poisson process with a slowly varying random intensity. Analogous experiments that rely on ionizing radiation and direct-conversion solid-state radiation detectors are proposed.
The paper investigates the origin of approximately 1/f21/f^21/f2 photon-count spectra at very low frequencies, reviewing previously reported measurements and examining possible explanations. Experiments conducted over 1.5 years used LEDs, superluminescent diodes, laser diodes, incandescent sources, and tritium-driven phosphor luminescence, with SPAD and PMT detection. Most records lasted 11.6 days, with counts collected in 5-s windows at roughly 2×105 s−12\times10^5\,\mathrm{s}^{-1}2×105s−1.
Across these sources, normalized periodograms follow approximately 1/f21/f^21/f2 over 10−610^{-6}10−6–5×10−4 Hz5\times10^{-4}\,\mathrm{Hz}5×10−4Hz, corresponding to 33 minutes–11.6 days. Wavelet variances show corresponding quadratic scaling. Simultaneous split-beam measurements exhibit correlated slow fluctuations in different detectors; shuffling count order removes the spectral structure while preserving count histograms. These observations motivate a Cox-process description: conditionally Poisson counts driven by a slowly fluctuating random intensity, yielding excess count variance and an intensity spectrum above the white shot-noise floor.
Comparisons with electrical and temperature records, dark-count measurements, detector technologies, and operating conditions are used to argue against conventional source, detector, optical, and environmental explanations. Betaluminescence establishes that an applied electrical drive is unnecessary. Several technical-noise exclusions rely on consistency across configurations rather than direct quantitative bounds.
The physical mechanism remains unresolved. Integrated forcing, mean-reverting diffusion, and intermittent diffusion are discussed as phenomenological possibilities, without identifying a driver. The accessible band is limited by record duration and noise, leaving a possible low-frequency rollover untested. Proposed simultaneous independent-source and direct ionizing-radiation measurements would help distinguish source-specific fluctuations from a common external influence.
Understanding photon-count dynamics is crucial for applications such as quantum random number generators and quantum key distributions, where random and memoryless photon-count arrival processes are essential for performance and security. We investigated the fluctuation dynamics of aggregated photon-count time series for two distinct light sources: a 780-nm laser diode and a spontaneous parametric down-conversion source, using detrended fluctuation analysis (DFA) and the index of dispersion for intervals (IDI). Despite the degradation of photon statistics to Poissonian due to optical losses and detector inefficiencies, our analysis reveals significant long-range dependence at large timescales. The DFA scaling exponents α[over ¯]>0.75 and IDI values c_{k}^{2}>1 at high mean photon count and large aggregation timescales indicate photon-count fluctuations deviated from Poisson model. Our findings underscore the necessity of models beyond Poisson statistics to accurately describe the photon-count dynamics over extended timescales.
Exact photocounting distributions are obtained for a pulse of light whose intensity is exponentially decaying in time, when the underlying photon statistics are Poisson. It is assumed that the starting time for the sampling interval (which is of arbitrary duration) is uniformly distributed. The probability of registering n counts in the fixed time T is given in terms of the incomplete gamma function for n >/= 1 and in terms of the exponential integral for n = 0. Simple closed-form expressions are obtained for the count mean and variance. The results are expected to be of interest in certain studies involving spontaneous emission, radiation damage in solids, and nuclear counting. They will also be useful in neurobiology and psychophysics, since habituation and sensitization processes may sometimes be characterized by the same stochastic model.
Abstract Photon counting provides a valuable tool for measuring quantum properties of light. Unavoidable imperfections of photon detectors lead to discrepancies between the statistics of photons and statistics of photon counts. Here we consider dead-time corrections and influence of intensity fluctuations for simulated Poissonian statistics of photo counts for the pulsed or continuous wave coherent light sources. We analyse dependence between the statistical moments of corrected distribution and the mean photon number, dead-time, and level of intensity fluctuations.
It is well known that photoelectric measurements yield information about the statistical behavior of fluctuating light beams. The probability of n photoelectrons being ejected, in a fixed time interval, from the photosensitive surface of the photoelectric detector, upon which the light beam is normally incident, is a linear (Poisson) transform of the probability density for the intensity of the beam. With the help of some plausible assumptions, the present analysis provides solutions to the problem of inverting the Poisson transform, thus determining the probability density for the intensity from experimentally obtained photocounting distributions. The effectiveness of the method is demonstrated by an actual inversion of a typical experimental counting distribution. The technique is of particular interest in connection with efforts to understand the statistical behavior of optical fields, especially of laser fields.