Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2610.03657

Super-Exponential Advantage of Squeezed Light in Phase Estimation under Discrete Phase Randomisation

Lorcan O. Conlon, V Vijendran, Aritra Das, Yu-Xin Wang, Erfan Abbasgholinejad, Anthony J. Brady, Jacob Bringewatt, Sean R. Muleady, Syed M. Assad, Alexey V. Gorshkov

quant-phSubmitted Oct 2, 2026• Announced Oct 5, 2026• 0 citations
arXivHTMLPDF

Abstract

A paradigmatic task in quantum metrology is that of phase estimation. For this task it is commonly believed, under reasonable assumptions about prior information, that a quadratic advantage in sensitivity is the maximum possible advantage offered by the use of quantum resources. In this work, we consider a channel that implements a phase shift by an angle $2πk/M$, where $k$ is a uniformly random unknown integer, in addition to a small unknown phase shift of interest. We show that, subject to a constraint on the mean photon number per channel use, there is a super-exponential separation between the quantum Fisher information (QFI) attainable using a squeezed vacuum state and that attainable using coherent states. This advantage holds over any state obtained from a coherent state via phase covariant channels. Specifically, when the mean photon number per channel use is 1, the ratio of their QFI grows as $Ω[(M/\sqrt{2}e)^M]$. For a mean photon number per channel use of $M/\log(M)$, the squeezed vacuum QFI is $Ω(M^{3/2}/\sqrt{\log(M)})$, whereas for a coherent state it is at most $\exp[-M\log\log(M)+O(M)]$. We complement this QFI analysis with non-asymptotic estimation results. For a mean photon number per channel use of $M/\log M$, an explicit squeezed-vacuum protocol estimates the phase to accuracy $O(1/M)$ using $O(\sqrt{M\log M})$ channel uses, whereas every coherent state protocol requires at least $\exp[M\log\log M-O(M)]$ channel uses. We consider the effects of noise and show that the ratio of their QFIs can still grow super-exponentially in $M$. Finally, under fixed optical loss and thermal noise, choosing $\bar n=M^2/(\log M)^{3/2}$ allows squeezed vacuum with heterodyne detection to achieve accuracy $O(1/M)$ using sub-polynomially many channel uses, whereas every protocol in the specified classical family requires super-polynomially many.

AI Summary

The paper asks whether single-parameter phase estimation can exhibit more than a quadratic quantum–classical separation when each channel use adds an independent, hidden, uniformly random phase $2\pi k/M$. It compares squeezed vacuum with coherent probes of equal mean photon number per use and a specified family obtained from coherent probes through loss, thermal noise, phase diffusion, rotations, and mixtures thereof. Discrete twirling preserves only Fock coherences separated by multiples of $M$. For pure probes, the QFI is $4\mathbb E[\operatorname{Var}(N\mid N\bmod M)]$. Comparing Poisson and squeezed-vacuum photon-number tails gives, at $\bar n=1$, a QFI ratio $\Omega[(M/(\sqrt2e))^M]$. At $\bar n=M/\log M$, squeezed-vacuum QFI is $\Omega(M^{3/2}/\sqrt{\log M})$, whereas coherent-state QFI is at most $\exp[-M\log\log M+O(M)]$. Explicit measurements and finite-sample estimators achieve error $b/M$ using $O(\sqrt{M\log M})$ squeezed-probe samples at fixed confidence; testing bounds require $\exp[M\log\log M-O(M)]$ classical samples. Under fixed optical loss and thermal noise, choosing $\bar n=M^2/(\log M)^{3/2}$ yields subpolynomial sample complexity with squeezing and heterodyne detection versus superpolynomial classical complexity. The separation reflects suppression of the benchmark, not precision beyond Heisenberg scaling. It excludes rare bright classical pulses and assumes a phase interval shrinking as $1/M$. At fixed energy, squeezed-probe information also decays exponentially. Fixed phase diffusion destroys nonvanishing QFI for every input, irrespective of energy; growing-energy implementations therefore require increasing squeezing and controlled phase stability.

Little sign of AI-generated textStrong assumptions

Central claim may not hold: The abstract's coherent-protocol lower bounds require the body's restriction on generating coherent-state energy, because an unconditional mean-photon-number budget permits rare bright coherent pulses that achieve polynomial sample complexity.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
10 page main text, comments very welcome

Related papers

Adaptive phase estimation with squeezed thermal light

Adriano Berni, Lars S. Madsen, Mikael Lassen +3 more

Summary form only given. The use of quantum states of light in optical interferometry improves the precision in the estimation of a phase shift, paving the way for applications in quantum metrology, computation and cryptography. Sub-shot noise phase sensing can for example be achieved by injecting a squeezed vacuum into an interferometer . However, this approach leads to enhanced sensitivity only for small phase shifts. In this work we aim for ab initio sub-shot noise estimation of an unknown phase shift using a pre-determined squeezed probe and an adaptive measurement approach. We experimentally investigate the performances of such protocol under the realistic assumption of thermalization of the probe state. Indeed, adaptive phase estimation schemes with squeezed states and Bayesian processing of homodyne data have been shown to be asymptotically optimal in the pure case, thus approaching the quantum Cramér-Rao bound. In our protocol we take advantage of the enhanced sensitivity of homodyne detection in proximity of the optimal phase which maximizes the homodyne Fisher information. A squeezed thermal probe state (signal) undergoes an unknown phase shift. The first estimation step involves interference on a beam splitter of the signal and a local oscillator followed by homodyne detection. Homodyne data is then processed to compute a rough estimation of the phase through Bayesian inference. The rough estimation is fed back to the local oscillator in order to match the optimal relative phase with the signal. A second estimation step leads to the final estimation of the phase shift. Thermalization of the probe state prevents the attainability of the quantum Cramér-Rao bound. Nevertheless, we show that the studied adaptive scheme still saturates the classical Cramér-Rao bound, showing sub-shot noise behaviour and therefore extracting the maximum available information from homodyne data. In contrast to previous approaches, our scheme is optimized for Gaussian states.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations

Effects of photon losses on phase estimation near the Heisenberg limit using coherent light and squeezed vacuum

Takafumi Ono, Holger Friedrich Hofmann

Two-path interferometry with coherent states and a squeezed vacuum can achieve phase sensitivities close to the Heisenberg limit when the average photon number of the squeezed vacuum is close to the average photon number of the coherent light. Here, we investigate the phase sensitivity of such states in the presence of photon losses. It is shown that the Cramer-Rao bound of phase sensitivity can be achieved experimentally by using a weak local oscillator and photon counting in the output. The phase sensitivity is then given by the Fisher information $F$ of the state. In the limit of high squeezing, the ratio $(F--N)/{N}^{2}$ of Fisher information above shot noise to the square of the average photon number $N$ depends only on the average number of photons lost, ${n}_{\mathrm{loss}}$, and the fraction of squeezed vacuum photons $\ensuremath{\mu}$. For $\ensuremath{\mu}=1/2$, the effect of losses is given by $(F--N)/{N}^{2}=1/(1+2{n}_{\mathrm{loss}})$. The possibility of increasing the robustness against losses by lowering the squeezing fraction $\ensuremath{\mu}$ is considered, and an optimized result is derived. However, the improvements are rather small, with a maximal improvement by a factor of 2 at high losses.

arXiv:0910.3727•Physical Review A•Mar 11, 2010•101 citations

Quantum Metrology of Noisy Spreading Channels

Wojciech Górecki, Alberto Riccardi, Lorenzo Maccone

We provide the optimal measurement strategy for a class of noisy channels that reduce to the identity channel for a specific value of a parameter (spreading channels). We provide an example that is physically relevant: the estimation of the absolute value of the displacement in the presence of phase randomizing noise. Surprisingly, this noise does not affect the effectiveness of the optimal measurement. We show that, for small displacement, a squeezed vacuum probe field is optimal among strategies with same average energy. A squeezer followed by photodetection is the optimal detection strategy that attains the quantum Fisher information, whereas the customarily used homodyne detection becomes useless in the limit of small displacements, due to the same effect that gives Rayleigh's curse in optical superresolution. There is a quantum advantage: a squeezed or a Fock state with N average photons allow to asymptotically estimate the parameter with a sqrt[N] better precision than classical states with same energy.

arXiv:2208.09386•Physical Review Letters•Dec 7, 2022•34 citations

Sub-shot-noise-limited phase estimation via single-mode inputs

Jiandong Zhang, Chenglong You, Shuai Wang

In 1981, Caves pointed out that the phase sensitivity of a Mach-Zehnder interferometer with single-mode inputs is bounded by the shot-noise limit. The quantum Fisher information analysis shows that this statement holds true for the scenario where two antisymmetric phase shifts occur in two arms, but it is invalid for the scenario where an unknown phase is embedded in one of two arms. In this paper, we focus on the phase sensitivity directed against the latter scenario. The optimal single-mode input is discussed by analyzing common states, including displaced squeezed states, displaced number states, squeezed number states, Schrödinger cat states and completely mixed states. We find that the best choice is a squeezed vacuum state and show the specific measurement scheme which is capable of saturating the corresponding phase sensitivity limit. In addition, we study the effects of several realistic factors-anti-squeezing noise, photon loss and dark counts-on the phase sensitivity. Our results suggest that sub-shot-noise-limited phase sensitivity is attainable with low noise or loss, which paves the way for practical metrology.

Optics Express•Oct 24, 2022•2 citations

Quantum accuracy limits and benchmarks in continuous variable systems

Mariona Aspachs

In this thesis I study optimal strategies to estimate or characterize quantum states and processes (quantum channels). I consider the problem of estimating a phase encoded on a gaussian state. Phase estimation is at the heart of many quantum metrology applications, such as gravitational wave detectors or clock synchronization. I address the problem to the phase estimation fidelity for pure and mixed gaussian states and study how temperature affects the precision of estimation. Although the case of pure states has been studied before, very little is known about estimation in mixed states. The interest in mixed gaussian states relies on the fact that these are the states one has in real experiments with light due to the unavoidable presence of noise. Displaced and squeezed thermal states are studied. For the case of displaced states, I find that fidelity estimation gets worse when the temperature increases. On the contrary, for squeezed thermal states I find the surprising result that a larger temperature yields better estimation. This apparently paradoxical feature, also appears when I derive the estimation accuracy that can be obtained when an asymptotically large number of copies of the state is available. I also study quantum benchmarks that can be applied to a wide variety of protocols, such us quantum storage or quantum teleportation. A very important question in QIT is to know whether a particular quantum protocol can be realized by classical means with the same efficiency. After all, QIT lives from the promise of this quantum advantage. This question becomes specially relevant in experimental (real) implementations of quantum schemes. In real experiments there are always losses and the ideal quantum protocols become imperfect. It is then necessary to assess whether the same experimental result could be obtained by classical (less costly) means. So, for example, in a particular teleportation experiment -which involves generation of entanglement, complicated Bell measurements, fighting decoherence, etc.- one might ask whether one could achieve the same (i.e. mapping the state of a system to a second system located in a different place or time) by measuring the system, transmitting the collected information to the other location, and finally preparing the system accordingly. It is hence of paramount importance to give bounds on the efficiency of these measure and prepare (or entanglement breaking) channels. For this purpose we propose a threshold based on a phase-covariant family of states. Besides of being a family with a straightforward group-theoretical structure, which gives obvious computational advantages, this family is interesting because it can be tested experimentally also in a straightforward way. A crucial feature for the practical use of our benchmark is that it does not require pure (ideal) input states. I finally consider the problem of estimating the parameter of the amplification channel. The amplification channel is interesting by itself but also by the fact that the Hawking-Unruh effect can be formally modeled by it. The Unruh-Hawking effect is a relativistic effect and as such it is hard to measure and detect in current experiments. I investigate whether quantum strategies can provide an improvement over classical protocols in the estimation of the amplification parameter. If the field is inertially prepared in the vacuum one could measure its temperature as detected by a noninertial observer and extract information about the parameter. But I would like to know if the vacuum state is the optimal probe state in an inertial frame for such a task or a better sensitivity could be achieved if the field were in a state of nonzero energy (mean photon number) from an inertial perspective. The aim is to determine the optimal input states, so that, by optimally measuring the output, one can construct an estimator for amplification channel parameter which is unbiased and has the minimum possible variance.

•Jan 1, 2011•0 citations

Precision Limits and Non-Gaussian Advantage in Optical Phase Estimation under Preparation Constraints

Víctor Izquierdo, Javier Lalueza-Puértolas

In optical quantum metrology, the scaling of the quantum Fisher information (QFI) with the mean photon number is a standard benchmark for relating precision to probe resources. For phase estimation, Heisenberg scaling corresponds to a quadratic growth of the QFI with the mean photon number, which Gaussian probes can approach. Interestingly, certain non-Gaussian probes can exhibit arbitrarily large QFI even at fixed mean photon number. Here, we clarify the resource requirements underlying this behavior by introducing a constraint that separates physically admissible states from inadmissible ones: an envelope on the photon-number distribution that arises naturally from the physical limitations of state-generation methods. Building on this constraint and considering pure single-mode probes, we define a resource quantity, $N_\mathrm{RMS}$, fixed by the preparation constraints, and derive a finite bound on the QFI whose Heisenberg scaling is attainable. We identify a genuine metrological advantage of non-Gaussian states over Gaussian probes subject to the same constraints. Finally, we illustrate these results with an optical preparation model based on a universal gate set.

arXiv:2611.06645•Nov 4, 2026•0 citations
A paradigmatic task in quantum metrology is that of phase estimation. For this task it is commonly believed, under reasonable assumptions about prior information, that a quadratic advantage in sensitivity is the maximum possible advantage offered by the use of quantum resources. In this work, we consider a channel that implements a phase shift by an angle 2πk/M2πk/M2πk/M, where kkk is a uniformly random unknown integer, in addition to a small unknown phase shift of interest. We show that, subject to a constraint on the mean photon number per channel use, there is a super-exponential separation between the quantum Fisher information (QFI) attainable using a squeezed vacuum state and that attainable using coherent states. This advantage holds over any state obtained from a coherent state via phase covariant channels. Specifically, when the mean photon number per channel use is 1, the ratio of their QFI grows as Ω[(M/2e)M]Ω[(M/\sqrt{2}e)^M]Ω[(M/2​e)M]. For a mean photon number per channel use of M/log⁡(M)M/\log(M)M/log(M), the squeezed vacuum QFI is Ω(M3/2/log⁡(M))Ω(M^{3/2}/\sqrt{\log(M)})Ω(M3/2/log(M)​), whereas for a coherent state it is at most exp⁡[−Mlog⁡log⁡(M)+O(M)]\exp[-M\log\log(M)+O(M)]exp[−Mloglog(M)+O(M)]. We complement this QFI analysis with non-asymptotic estimation results. For a mean photon number per channel use of M/log⁡MM/\log MM/logM, an explicit squeezed-vacuum protocol estimates the phase to accuracy O(1/M)O(1/M)O(1/M) using O(Mlog⁡M)O(\sqrt{M\log M})O(MlogM​) channel uses, whereas every coherent state protocol requires at least exp⁡[Mlog⁡log⁡M−O(M)]\exp[M\log\log M-O(M)]exp[MloglogM−O(M)] channel uses. We consider the effects of noise and show that the ratio of their QFIs can still grow super-exponentially in MMM. Finally, under fixed optical loss and thermal noise, choosing nˉ=M2/(log⁡M)3/2\bar n=M^2/(\log M)^{3/2}nˉ=M2/(logM)3/2 allows squeezed vacuum with heterodyne detection to achieve accuracy O(1/M)O(1/M)O(1/M) using sub-polynomially many channel uses, whereas every protocol in the specified classical family requires super-polynomially many.
The paper asks whether single-parameter phase estimation can exhibit more than a quadratic quantum–classical separation when each channel use adds an independent, hidden, uniformly random phase 2πk/M2\pi k/M2πk/M. It compares squeezed vacuum with coherent probes of equal mean photon number per use and a specified family obtained from coherent probes through loss, thermal noise, phase diffusion, rotations, and mixtures thereof.
Discrete twirling preserves only Fock coherences separated by multiples of MMM. For pure probes, the QFI is 4E[Var⁡(N∣N mod M)]4\mathbb E[\operatorname{Var}(N\mid N\bmod M)]4E[Var(N∣NmodM)]. Comparing Poisson and squeezed-vacuum photon-number tails gives, at nˉ=1\bar n=1nˉ=1, a QFI ratio Ω[(M/(2e))M]\Omega[(M/(\sqrt2e))^M]Ω[(M/(2​e))M]. At nˉ=M/log⁡M\bar n=M/\log Mnˉ=M/logM, squeezed-vacuum QFI is Ω(M3/2/log⁡M)\Omega(M^{3/2}/\sqrt{\log M})Ω(M3/2/logM​), whereas coherent-state QFI is at most exp⁡[−Mlog⁡log⁡M+O(M)]\exp[-M\log\log M+O(M)]exp[−MloglogM+O(M)]. Explicit measurements and finite-sample estimators achieve error b/Mb/Mb/M using O(Mlog⁡M)O(\sqrt{M\log M})O(MlogM​) squeezed-probe samples at fixed confidence; testing bounds require exp⁡[Mlog⁡log⁡M−O(M)]\exp[M\log\log M-O(M)]exp[MloglogM−O(M)] classical samples.
Under fixed optical loss and thermal noise, choosing nˉ=M2/(log⁡M)3/2\bar n=M^2/(\log M)^{3/2}nˉ=M2/(logM)3/2 yields subpolynomial sample complexity with squeezing and heterodyne detection versus superpolynomial classical complexity. The separation reflects suppression of the benchmark, not precision beyond Heisenberg scaling. It excludes rare bright classical pulses and assumes a phase interval shrinking as 1/M1/M1/M. At fixed energy, squeezed-probe information also decays exponentially. Fixed phase diffusion destroys nonvanishing QFI for every input, irrespective of energy; growing-energy implementations therefore require increasing squeezing and controlled phase stability.
Summary form only given. The use of quantum states of light in optical interferometry improves the precision in the estimation of a phase shift, paving the way for applications in quantum metrology, computation and cryptography. Sub-shot noise phase sensing can for example be achieved by injecting a squeezed vacuum into an interferometer . However, this approach leads to enhanced sensitivity only for small phase shifts. In this work we aim for ab initio sub-shot noise estimation of an unknown phase shift using a pre-determined squeezed probe and an adaptive measurement approach. We experimentally investigate the performances of such protocol under the realistic assumption of thermalization of the probe state. Indeed, adaptive phase estimation schemes with squeezed states and Bayesian processing of homodyne data have been shown to be asymptotically optimal in the pure case, thus approaching the quantum Cramér-Rao bound. In our protocol we take advantage of the enhanced sensitivity of homodyne detection in proximity of the optimal phase which maximizes the homodyne Fisher information. A squeezed thermal probe state (signal) undergoes an unknown phase shift. The first estimation step involves interference on a beam splitter of the signal and a local oscillator followed by homodyne detection. Homodyne data is then processed to compute a rough estimation of the phase through Bayesian inference. The rough estimation is fed back to the local oscillator in order to match the optimal relative phase with the signal. A second estimation step leads to the final estimation of the phase shift. Thermalization of the probe state prevents the attainability of the quantum Cramér-Rao bound. Nevertheless, we show that the studied adaptive scheme still saturates the classical Cramér-Rao bound, showing sub-shot noise behaviour and therefore extracting the maximum available information from homodyne data. In contrast to previous approaches, our scheme is optimized for Gaussian states.
Two-path interferometry with coherent states and a squeezed vacuum can achieve phase sensitivities close to the Heisenberg limit when the average photon number of the squeezed vacuum is close to the average photon number of the coherent light. Here, we investigate the phase sensitivity of such states in the presence of photon losses. It is shown that the Cramer-Rao bound of phase sensitivity can be achieved experimentally by using a weak local oscillator and photon counting in the output. The phase sensitivity is then given by the Fisher information FFF of the state. In the limit of high squeezing, the ratio (F−−N)/N2(F--N)/{N}^{2}(F−−N)/N2 of Fisher information above shot noise to the square of the average photon number NNN depends only on the average number of photons lost, nloss{n}_{\mathrm{loss}}nloss​, and the fraction of squeezed vacuum photons $\ensuremath{\mu}$. For $\ensuremath{\mu}=1/2$, the effect of losses is given by (F−−N)/N2=1/(1+2nloss)(F--N)/{N}^{2}=1/(1+2{n}_{\mathrm{loss}})(F−−N)/N2=1/(1+2nloss​). The possibility of increasing the robustness against losses by lowering the squeezing fraction $\ensuremath{\mu}$ is considered, and an optimized result is derived. However, the improvements are rather small, with a maximal improvement by a factor of 2 at high losses.
We provide the optimal measurement strategy for a class of noisy channels that reduce to the identity channel for a specific value of a parameter (spreading channels). We provide an example that is physically relevant: the estimation of the absolute value of the displacement in the presence of phase randomizing noise. Surprisingly, this noise does not affect the effectiveness of the optimal measurement. We show that, for small displacement, a squeezed vacuum probe field is optimal among strategies with same average energy. A squeezer followed by photodetection is the optimal detection strategy that attains the quantum Fisher information, whereas the customarily used homodyne detection becomes useless in the limit of small displacements, due to the same effect that gives Rayleigh's curse in optical superresolution. There is a quantum advantage: a squeezed or a Fock state with N average photons allow to asymptotically estimate the parameter with a sqrt[N] better precision than classical states with same energy.
In 1981, Caves pointed out that the phase sensitivity of a Mach-Zehnder interferometer with single-mode inputs is bounded by the shot-noise limit. The quantum Fisher information analysis shows that this statement holds true for the scenario where two antisymmetric phase shifts occur in two arms, but it is invalid for the scenario where an unknown phase is embedded in one of two arms. In this paper, we focus on the phase sensitivity directed against the latter scenario. The optimal single-mode input is discussed by analyzing common states, including displaced squeezed states, displaced number states, squeezed number states, Schrödinger cat states and completely mixed states. We find that the best choice is a squeezed vacuum state and show the specific measurement scheme which is capable of saturating the corresponding phase sensitivity limit. In addition, we study the effects of several realistic factors-anti-squeezing noise, photon loss and dark counts-on the phase sensitivity. Our results suggest that sub-shot-noise-limited phase sensitivity is attainable with low noise or loss, which paves the way for practical metrology.
In this thesis I study optimal strategies to estimate or characterize quantum states and processes (quantum channels). I consider the problem of estimating a phase encoded on a gaussian state. Phase estimation is at the heart of many quantum metrology applications, such as gravitational wave detectors or clock synchronization. I address the problem to the phase estimation fidelity for pure and mixed gaussian states and study how temperature affects the precision of estimation. Although the case of pure states has been studied before, very little is known about estimation in mixed states. The interest in mixed gaussian states relies on the fact that these are the states one has in real experiments with light due to the unavoidable presence of noise. Displaced and squeezed thermal states are studied. For the case of displaced states, I find that fidelity estimation gets worse when the temperature increases. On the contrary, for squeezed thermal states I find the surprising result that a larger temperature yields better estimation. This apparently paradoxical feature, also appears when I derive the estimation accuracy that can be obtained when an asymptotically large number of copies of the state is available. I also study quantum benchmarks that can be applied to a wide variety of protocols, such us quantum storage or quantum teleportation. A very important question in QIT is to know whether a particular quantum protocol can be realized by classical means with the same efficiency. After all, QIT lives from the promise of this quantum advantage. This question becomes specially relevant in experimental (real) implementations of quantum schemes. In real experiments there are always losses and the ideal quantum protocols become imperfect. It is then necessary to assess whether the same experimental result could be obtained by classical (less costly) means. So, for example, in a particular teleportation experiment -which involves generation of entanglement, complicated Bell measurements, fighting decoherence, etc.- one might ask whether one could achieve the same (i.e. mapping the state of a system to a second system located in a different place or time) by measuring the system, transmitting the collected information to the other location, and finally preparing the system accordingly. It is hence of paramount importance to give bounds on the efficiency of these measure and prepare (or entanglement breaking) channels. For this purpose we propose a threshold based on a phase-covariant family of states. Besides of being a family with a straightforward group-theoretical structure, which gives obvious computational advantages, this family is interesting because it can be tested experimentally also in a straightforward way. A crucial feature for the practical use of our benchmark is that it does not require pure (ideal) input states. I finally consider the problem of estimating the parameter of the amplification channel. The amplification channel is interesting by itself but also by the fact that the Hawking-Unruh effect can be formally modeled by it. The Unruh-Hawking effect is a relativistic effect and as such it is hard to measure and detect in current experiments. I investigate whether quantum strategies can provide an improvement over classical protocols in the estimation of the amplification parameter. If the field is inertially prepared in the vacuum one could measure its temperature as detected by a noninertial observer and extract information about the parameter. But I would like to know if the vacuum state is the optimal probe state in an inertial frame for such a task or a better sensitivity could be achieved if the field were in a state of nonzero energy (mean photon number) from an inertial perspective. The aim is to determine the optimal input states, so that, by optimally measuring the output, one can construct an estimator for amplification channel parameter which is unbiased and has the minimum possible variance.
In optical quantum metrology, the scaling of the quantum Fisher information (QFI) with the mean photon number is a standard benchmark for relating precision to probe resources. For phase estimation, Heisenberg scaling corresponds to a quadratic growth of the QFI with the mean photon number, which Gaussian probes can approach. Interestingly, certain non-Gaussian probes can exhibit arbitrarily large QFI even at fixed mean photon number. Here, we clarify the resource requirements underlying this behavior by introducing a constraint that separates physically admissible states from inadmissible ones: an envelope on the photon-number distribution that arises naturally from the physical limitations of state-generation methods. Building on this constraint and considering pure single-mode probes, we define a resource quantity, NRMSN_\mathrm{RMS}NRMS​, fixed by the preparation constraints, and derive a finite bound on the QFI whose Heisenberg scaling is attainable. We identify a genuine metrological advantage of non-Gaussian states over Gaussian probes subject to the same constraints. Finally, we illustrate these results with an optical preparation model based on a universal gate set.