arXiv:2610.03040
Direct estimation of $g^{(2)}(0)$ from click statistics of a multiplexed detector
Jaromír Fiurášek
Abstract
We present and theoretically analyze a method for direct estimation of the second-order correlation function $g^{(2)}(0)$ from the click statistics of a multiplexed detector composed of M binary on-off detection channels. The method uses linear estimators of the first and second moments of the photon-number operator and can provide accurate results even for optical fields with substantial mean photon numbers. For a fixed number of channels, the detection range can be extended by introducing additional losses before the detector. We demonstrate the performance of the method for coherent, thermal, amplitude-squeezed, and photon-added coherent states. We also derive a nonclassicality criterion based on the estimated correlation function and show how the method can be adapted to unbalanced detectors. Our work establishes direct estimation of $g^{(2)}(0)$ as a simple and versatile method for quantitatively characterizing quantum light using multiplexed click detectors.
AI Summary
The paper studies how to estimate $g^{(2)}(0)$ directly from the total-click distribution of an $M$-channel multiplexed on–off detector, without reconstructing the photon-number distribution or using the weak-signal HBT approximation. It constructs linear estimators $\mu_1$ and $\mu_2$ of $\langle n\rangle$ and $\langle n^2\rangle$ by inverting the detector response restricted to photon numbers $0,\ldots,M$, then forms $g_M^{(2)}(0)=(\mu_2-\mu_1)/\mu_1^2$. The moment estimators are exact for states supported on this subspace; balanced-detector weights are given analytically using Stirling numbers. Calculations for coherent, thermal, amplitude-squeezed and single-photon-added coherent states assess systematic error beyond this cutoff. For $M=20$, the relative error in $g^{(2)}(0)$ for coherent light is of order $10^{-4}$ at mean photon number $20$. Thermal light has larger tail-induced errors, with a reliable plateau reported around mean photon numbers $\lesssim1$ for $M=10$ and $\lesssim4$ for $M=20$. Controlled attenuation extends the usable range because the true $g^{(2)}(0)$ is loss invariant. A nonclassicality witness compares the estimate against a coherent state having the same $\mu_1$, rather than against unity. Its validity for balanced detectors follows from a convexity proof. Calibrated channel imbalance is accommodated through a polynomial-time response calculation and numerical inversion. Limitations are bias above the cutoff, saturation at high intensity, and the need for assumptions on photon-number tails: unrestricted photon-number moments cannot be reliably inferred from finite click statistics. Dark counts are neglected in the main analysis.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 10 pages, 9 figures REVTeX4