arXiv:2609.37281
Scanless quantum Fourier-transform mid-infrared spectroscopy for solids and surface analysis
Paul Gattinger, Michela Conti, Franziska Dietz, Andrei N. Halangescu Moldovan, Andreas W. Schell, Markus Brandstetter, Ivan Zorin
Abstract
Quantum infrared (IR) spectroscopy is a novel technique based on nonlinear interferometry and quantum sensing with undetected photons. In this approach, spectrally far-separated correlated photon pairs are used for detection and probing, respectively. Hence, the probing wavelength domain (mid-IR) is substantially different from the detection spectral range (near-IR), which enables shot-noise-limited and cost-effective sensing schemes attractive for applied metrology. In this paper, we implement and employ a custom-built scanless quantum Fourier-transform mid-IR (sQFTIR) microspectrometer for chemical characterization and analysis of solids and interfaces. The sQFTIR system employs spectral-domain acquisition, without the need to scan the optical delay. This results in enhanced sensitivity and short measurement times and therefore enables rapid spectral acquisitions in 100~ms spanning a spectral band from 3000 cm$^{-1}$ - 2400 cm$^{-1}$. The capabilities of our approach are demonstrated for hyperspectral mid-IR imaging of dried pharmaceuticals (insulin on a gold surface) and investigation of a security feature on a banknote. Furthermore, we demonstrate hyperspectral imaging and spectroscopy through a turbid ceramic medium.
AI Summary
The paper investigates scanless mid-infrared spectroscopy with undetected photons for spatially resolved analysis of solids and interfaces. A double-pass nonlinear interferometer generates correlated near-IR signal and mid-IR idler photons in a periodically poled KTP crystal. The idler probes the sample in reflection; its spectral response is inferred from interference recorded by a near-IR spectrometer. Fourier-domain processing extracts the interference envelope without scanning the optical delay, although hyperspectral images require spatial raster scanning. The instrument acquires spectra over $3000$–$2400\,\mathrm{cm}^{-1}$ with $100\,\mathrm{ms}$ integration per spatial pixel. Measurements use spectral resolutions of $20$–$27\,\mathrm{cm}^{-1}$; the reported spatial resolution is $12.3\,\mu\mathrm{m}$. Demonstrations comprise a dried insulin deposit on gold, mapped over $397\times200$ pixels; a banknote security foil, mapped over $300\times131$ pixels; and polypropylene and PET films beneath a $300\,\mu\mathrm{m}$ alumina plate, mapped over $247\times101$ pixels. Extracted spectra are compared with literature absorption bands. The polymer films beneath alumina are distinguished spectrally, and interference fringes in the banknote measurement yield an estimated foil thickness of $48\,\mu\mathrm{m}$, assuming refractive index $1.5$. The paper notes that scattering makes measured absorbance an apparent absorbance with possible baseline distortion. Film-thickness variations and thin-film interference produce substantial spectral variability, while alumina scattering introduces residual ripples. The banknote spectra contain contributions from multiple layers and cannot unambiguously identify its polymer composition from the measured C–H stretching bands.
Error found: The abstract attributes enhanced sensitivity and shorter measurement times to spectral-domain acquisition, but the paper provides neither a quantitative sensitivity measurement nor a matched delay-scanned comparison establishing those improvements.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 8 pages, 4 figures