Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.32112

Enhancing Conversion Gain in HEB Mixers using Negative Differential Resistance

Boris S. Karasik, Changyun Yoo

Published Sep 26, 2026• 0 citations
arXivHTMLPDF

Abstract

This work investigates how negative differential resistance (NDR) can be utilized to enhance conversion gain in superconducting niobium nitride (NbN) hot-electron bolometer (HEB) mixers. Conventional HEB operation avoids NDR regions due to parasitic oscillations caused by interactions between thermal inertia and bias-line reactance. Recent experimental results show that reducing the bias-T inductance suppresses these oscillations and enables stable biasing within the NDR regime, thereby increasing the mixer conversion gain beyond levels achievable under positive differential resistance (PDR) bias. Using a lumped thermal-electrical model, we interpret these experimental findings, derive stability conditions for NDR-biased operation, and predict the future performance limits achievable through optimized bias circuit designs. Our results indicate that further reductions in bias inductance, combined with appropriate load-line conditions, could yield several decibels of additional gain while maintaining practical IF bandwidths.

DOI
10.48550/arxiv.2609.32112

Related papers

Hot-electron bolometric mixer with negative differential resistance

Changyun Yoo, Akim A. Babenko, Boris S. Karasik

We demonstrate that the conversion gain of a superconducting hot-electron bolometer (HEB) mixer can be increased by biasing the device within the negative differential resistance (NDR) region of its current–voltage characteristic. Although NDR biasing has historically been avoided due to MHz-range resistive oscillations, we show that these oscillations arise from an LC resonance formed by the bias-T inductance and the effective thermal capacitance of the HEB. By applying stability criteria analogous to those developed for tunnel diodes, we redesigned the embedding circuit to suppress this resonance and achieve stable NDR operation. Direct measurements using two monochromatic 2.5-THz sources confirm the predicted gain enhancement. These results establish NDR biasing as a viable method for improving HEB mixer performance and motivate further studies of noise behavior and circuit optimization.

arXiv:2605.05486•Applied Physics Letters•Jul 13, 2026•1 citation

A Large Signal Model for Phonon-Cooled Hot-Electron Bolometric Mixers for THz Frequency Applications

H. Merkel, E. Kollberg, K. S. Yngvesson

Phonon cooled hot electron bolometers (HEB) show smaller noise temperatures in mixer applications above 1THz compared to Schottky diodes or SIS devices. To determine the optimal bias point for maximum IF bandwidth and lowest noise of a FEB detailed understandin g of the current-voltage characteristic is indispensable. A complete nonlinear model for a hot electron bolometric (HEB) mixer is derived. The dynamic resistance of a superconducting film is calculated under stron g demagnetization conditions. The resistance is modeled due to vortex flow and phase slip lines. Self heating gives rise to normal domains in the film. In addition the resistance due to thermally activated flux creep and thermal fluctuations is taken into account. All these relations form a large si gnal model for the iv-characteristics and the bias points of the device. A small signal linearization yields then conversion gain and noise temperatures. Furthermore a quality measure for HEB devices is set up by deriving the thermal coupling of the film to the substrate and the achieved critical current density from measured current-voltage characteristics.

•Mar 1, 1998•8 citations

Characterization of Response Time of Superconducting NbN Hot Electron Bolometer Mixers

GuoAo Xie, Ruixuan Tang, Zhenlin Luo +6 more

Response time of a Superconducting Hot Electron Bolometer (HEB) mixers is a critical parameter, and significantly affects the intermediate frequency (IF) gain bandwidth. In this study, we investigated the effects of temperature and bias voltage on the response time. Response time of superconducting niobium nitride (NbN) HEB mixers were measured by using the pumpprobe technique at temperatures of 5 K, 7 K, and 9 K with different bias voltages. The measured response time ranged from 50 to 80 ps and decreased with increasing temperature and bias voltage. This approach provides a more comprehensive understanding of the thermal transport mechanisms in superconducting HEB mixers, which can ultimately lead to improved performance and properties of the HEB mixers.

International Conference on Electronics Technology (ICET)•May 17, 2025•0 citations

Linear and nonlinear characteristics of NbN hot electron bolometer devices

Yan Zhuang

The superconducting HEB device is so far the most promising low noise mixer in the THz frequency range. It out-performs other existing receiver systems because it has low noise temperature and sufficient bandwidth for applications in the FIR range such as astronomy, remote sensing and plasma diagnostics. This work investigates the linear and nonlinear characteristics of NbN Hot Electron Bolometer (HEB) devices. First of all, a thorough expression of the Johnson noise and the thermal fluctuation noise has been re-derived. Our circuit model is more preferable for the HEB devices than the traditional one being used for the semiconductor bolometer. Secondly, the equivalent noise temperature of our receiver system has been significantly improved: the noise temperature went from the original 5800K to a record of 500K for silicon substrate devices. We are also getting improved noise performance for the new MgO substrate devices. The simulation results agree with the measured data very well around the optimum operating point. Finally, the device in the unstable region can be stabilized by connecting a series resistor with higher resistance than the negative resistance of the device. Two frequencies are related to the oscillation waveforms of the voltage and the current of the device. The first one is the repetition frequency that is actually related to the external circuit. The second one is the relaxation frequency that is related to the intrinsic phenomena of the device itself. The domain wall velocity and the relaxation oscillation frequency have been calculated both theoretically and experimentally. The calculated results are within a satisfactory range compared with the measured data. Also, a thorough explanation of the device oscillation process has been presented.

Journal of Bioresource Management•Jan 1, 2002•4 citations

Reduced Tc Niobium superconducting HEB mixers

Henry George LeDuc, B. Bumble, Irfan A. Siddiqi +1 more

A reduction in the mixer noise is expected when using superconductors with a lower transition temperature (Tc) since the thermal noise components of the mixer noise should scale with Tc. Also, the local oscillator (LO) power required for a diffusion-cooled device should decrease as Tc when Tbath<<Tc. We previously studied mixing in aluminum based hot-electron bolometers (HEBs) at microwave frequencies (~30 GHz), and observed a significant improvement in noise performance, and a reduction in LO power as predicted. However, the bias voltage range over which good mixer performance was observed was ~ 5-10 μV. These devices are thus susceptible to saturation effects, in particular output saturation. In the present work, we have investigated Nb HEBs whose Tc is lowered by applying a magnetic field. The goal is to study a case intermediate between Nb and Al, and hopefully to find properties that will allow use in practical receivers. A 15 kOe perpendicular magnetic field was applied to a Nb HEB (L=0.16 μm, W=0.08 μm, RN=90Ω) to reduce Tc from 5.2 K to 2.4 K. The mixer noise, as inferred from the output noise and the conversion efficiency, decreased from 390 K, DSB to 171 K, DSB. The LO power required for near optimum mixer conversion efficiency (ηmixer = 9 dB in this device) was 8nW in zero field, and ~ 2 nW when Tc was reduced to 2.4K. Tbath=0.22K. The conversion bandwidth was previously measured to be 2.4 GHz and the same bandwidth was observed in the presence of a magnetic field. By lowering Tc, the voltage range over which good mixing was observed also decreased. However, even with Tc reduced to 2.4 K, the conversion efficiency dropped by 3dB from its maximum value only when the bias voltage was changed by ~ 90 μV. Saturation effects should thus be much less of a concern in these devices than in Al HEBs. In situations where the application of a large magnetic field is not feasible, we suggest using Ta based HEBs. Ta HEBs should have Tc ~ 3-3.5K and material properties very similar to Nb.

•Feb 14, 2001•0 citations

A hot-spot mixer model for phonon-cooled NbN hot electron bolometric mixers

H. Merkel, P. Khosropanah, Pavel A. Yagoubov +1 more

Based on a one dimensional heat transport equation for the electrons in a super-conducting hot electron bolometer (HEB) a model for a hot spot mixer is see up. The hot spot parameters are applied in a small signal oscillator model predicting IV curves and conversion gain. Besides its normal resistance and its IF bandwidth a HEB around its optimal operating point is sufficiently characterized by its hot spot length as a function of heating power. All mixer properties can be derived from this parameter set.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•30 citations
This work investigates how negative differential resistance (NDR) can be utilized to enhance conversion gain in superconducting niobium nitride (NbN) hot-electron bolometer (HEB) mixers. Conventional HEB operation avoids NDR regions due to parasitic oscillations caused by interactions between thermal inertia and bias-line reactance. Recent experimental results show that reducing the bias-T inductance suppresses these oscillations and enables stable biasing within the NDR regime, thereby increasing the mixer conversion gain beyond levels achievable under positive differential resistance (PDR) bias. Using a lumped thermal-electrical model, we interpret these experimental findings, derive stability conditions for NDR-biased operation, and predict the future performance limits achievable through optimized bias circuit designs. Our results indicate that further reductions in bias inductance, combined with appropriate load-line conditions, could yield several decibels of additional gain while maintaining practical IF bandwidths.
We demonstrate that the conversion gain of a superconducting hot-electron bolometer (HEB) mixer can be increased by biasing the device within the negative differential resistance (NDR) region of its current–voltage characteristic. Although NDR biasing has historically been avoided due to MHz-range resistive oscillations, we show that these oscillations arise from an LC resonance formed by the bias-T inductance and the effective thermal capacitance of the HEB. By applying stability criteria analogous to those developed for tunnel diodes, we redesigned the embedding circuit to suppress this resonance and achieve stable NDR operation. Direct measurements using two monochromatic 2.5-THz sources confirm the predicted gain enhancement. These results establish NDR biasing as a viable method for improving HEB mixer performance and motivate further studies of noise behavior and circuit optimization.
Phonon cooled hot electron bolometers (HEB) show smaller noise temperatures in mixer applications above 1THz compared to Schottky diodes or SIS devices. To determine the optimal bias point for maximum IF bandwidth and lowest noise of a FEB detailed understandin g of the current-voltage characteristic is indispensable. A complete nonlinear model for a hot electron bolometric (HEB) mixer is derived. The dynamic resistance of a superconducting film is calculated under stron g demagnetization conditions. The resistance is modeled due to vortex flow and phase slip lines. Self heating gives rise to normal domains in the film. In addition the resistance due to thermally activated flux creep and thermal fluctuations is taken into account. All these relations form a large si gnal model for the iv-characteristics and the bias points of the device. A small signal linearization yields then conversion gain and noise temperatures. Furthermore a quality measure for HEB devices is set up by deriving the thermal coupling of the film to the substrate and the achieved critical current density from measured current-voltage characteristics.
Response time of a Superconducting Hot Electron Bolometer (HEB) mixers is a critical parameter, and significantly affects the intermediate frequency (IF) gain bandwidth. In this study, we investigated the effects of temperature and bias voltage on the response time. Response time of superconducting niobium nitride (NbN) HEB mixers were measured by using the pumpprobe technique at temperatures of 5 K, 7 K, and 9 K with different bias voltages. The measured response time ranged from 50 to 80 ps and decreased with increasing temperature and bias voltage. This approach provides a more comprehensive understanding of the thermal transport mechanisms in superconducting HEB mixers, which can ultimately lead to improved performance and properties of the HEB mixers.
The superconducting HEB device is so far the most promising low noise mixer in the THz frequency range. It out-performs other existing receiver systems because it has low noise temperature and sufficient bandwidth for applications in the FIR range such as astronomy, remote sensing and plasma diagnostics. This work investigates the linear and nonlinear characteristics of NbN Hot Electron Bolometer (HEB) devices. First of all, a thorough expression of the Johnson noise and the thermal fluctuation noise has been re-derived. Our circuit model is more preferable for the HEB devices than the traditional one being used for the semiconductor bolometer. Secondly, the equivalent noise temperature of our receiver system has been significantly improved: the noise temperature went from the original 5800K to a record of 500K for silicon substrate devices. We are also getting improved noise performance for the new MgO substrate devices. The simulation results agree with the measured data very well around the optimum operating point. Finally, the device in the unstable region can be stabilized by connecting a series resistor with higher resistance than the negative resistance of the device. Two frequencies are related to the oscillation waveforms of the voltage and the current of the device. The first one is the repetition frequency that is actually related to the external circuit. The second one is the relaxation frequency that is related to the intrinsic phenomena of the device itself. The domain wall velocity and the relaxation oscillation frequency have been calculated both theoretically and experimentally. The calculated results are within a satisfactory range compared with the measured data. Also, a thorough explanation of the device oscillation process has been presented.
A reduction in the mixer noise is expected when using superconductors with a lower transition temperature (Tc) since the thermal noise components of the mixer noise should scale with Tc. Also, the local oscillator (LO) power required for a diffusion-cooled device should decrease as Tc when Tbath<<Tc. We previously studied mixing in aluminum based hot-electron bolometers (HEBs) at microwave frequencies (~30 GHz), and observed a significant improvement in noise performance, and a reduction in LO power as predicted. However, the bias voltage range over which good mixer performance was observed was ~ 5-10 μV. These devices are thus susceptible to saturation effects, in particular output saturation. In the present work, we have investigated Nb HEBs whose Tc is lowered by applying a magnetic field. The goal is to study a case intermediate between Nb and Al, and hopefully to find properties that will allow use in practical receivers. A 15 kOe perpendicular magnetic field was applied to a Nb HEB (L=0.16 μm, W=0.08 μm, RN=90Ω) to reduce Tc from 5.2 K to 2.4 K. The mixer noise, as inferred from the output noise and the conversion efficiency, decreased from 390 K, DSB to 171 K, DSB. The LO power required for near optimum mixer conversion efficiency (ηmixer = 9 dB in this device) was 8nW in zero field, and ~ 2 nW when Tc was reduced to 2.4K. Tbath=0.22K. The conversion bandwidth was previously measured to be 2.4 GHz and the same bandwidth was observed in the presence of a magnetic field. By lowering Tc, the voltage range over which good mixing was observed also decreased. However, even with Tc reduced to 2.4 K, the conversion efficiency dropped by 3dB from its maximum value only when the bias voltage was changed by ~ 90 μV. Saturation effects should thus be much less of a concern in these devices than in Al HEBs. In situations where the application of a large magnetic field is not feasible, we suggest using Ta based HEBs. Ta HEBs should have Tc ~ 3-3.5K and material properties very similar to Nb.
Based on a one dimensional heat transport equation for the electrons in a super-conducting hot electron bolometer (HEB) a model for a hot spot mixer is see up. The hot spot parameters are applied in a small signal oscillator model predicting IV curves and conversion gain. Besides its normal resistance and its IF bandwidth a HEB around its optimal operating point is sufficiently characterized by its hot spot length as a function of heating power. All mixer properties can be derived from this parameter set.