Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.31049

Computational aberration-retrieval with entangled photons

Baptiste Courme, YoonSeok Baek, Hugo Defienne

quant-phphysics.opticsSubmitted Sep 25, 2026• Announced Sep 28, 2026• 0 citations
arXivHTMLPDF

Abstract

Adaptive optics (AO) is central to high-resolution microscopy, yet conventional implementations often require repeated correction-and-measurement cycles whose number increases with aberration complexity. This measurement burden can become prohibitive when the available temporal window for correction is short or when photon budgets are constrained. Here, we demonstrate an AO strategy that exploits the spatial correlations of entangled photon pairs to retrieve aberrations directly. By using the second-order correlation function as an aberration-sensitive metric, the required correction can be determined with only a few measurements, without relying on image-based feedback or iterative optimization. This correlation-based approach establishes an efficient framework for AO leveraging quantum light, offering a new route toward quantum-enhanced microscopy in regimes where conventional correction strategies become challenging.

AI Summary

The paper addresses whether spatial correlations of entangled photon pairs can support adaptive-optics aberration retrieval with fewer hardware measurements than iterative sensorless correction. For strongly position-anticorrelated pairs, assuming shift-invariant imaging and sufficiently limited aberration complexity, the sum-coordinate projection of the coincidence function satisfies $C^+\propto|h*h|^2$, independently of the object’s spatial structure. Known pupil-plane phase perturbations provide magnitude constraints for computationally retrieving this effective response and extracting a corrective phase. The method uses 3–5 perturbations in simulations and experiments. Acquisition avoids iterative hardware optimization, but reconstruction uses an iterative phase-retrieval algorithm, supplemented by multiple response estimates and singular-value decomposition to handle noise. Experiments generate approximately 810-nm photon pairs using a 405-nm-pumped, 0.5-mm BBO crystal and measure correlations with a $32\times64$-pixel SPAD array. Five random SLM masks enable correction of imposed defocus/astigmatism and speckle-like aberrations, restoring a concentrated correlation peak. Imaging an insect specimen demonstrates recovery of major spatial features after correction; fine-detail recovery remains incomplete because weaker illumination at the pupil periphery limits phase estimation there. The stated applicability constraints are the need to preserve strong correlations at the object and long acquisition times. Aberrations in the illumination path can weaken those correlations, complicating use in embedded specimens. Each correlation image currently requires over $10^7$ frames and several hours, precluding real-time correction. Faster detectors and brighter sources are proposed routes to shorter acquisitions, rather than demonstrated capabilities of this implementation.

Little sign of AI-generated textOverclaimsMissing comparisonStrong assumptions

Error found: The claimed absence of iterative optimization needs qualification because reconstruction uses iterative magnitude projections, although repeated hardware optimization is avoided. The five reported measurements are correlation acquisitions taking several hours each, so the experiment establishes fewer hardware settings but not a practical acquisition-time or photon-budget advantage. The coherent-PSF recovery formula incorrectly uses |F(H)| instead of sqrt(|F(H)|) for its Fourier-domain amplitude, while its phase-halving operation remains consistent with H = h*h.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Related papers

Position-correlated biphoton wavefront sensing for quantum adaptive imaging

Yi Zheng, Zhao-Di Liu, Jian‐Shun Tang +3 more

Quantum imaging with spatially entangled photons offers advantages such as enhanced spatial resolution, robustness against noise, and counterintuitive phenomena, while a biphoton spatial aberration generally degrades its performance. Biphoton aberration correction has been achieved by using classical beams to detect the aberration source or scanning the correction phase on biphotons if the source is unreachable. Here, a new method named position-correlated biphoton Shack-Hartmann wavefront sensing is introduced, where the phase pattern added on photon pairs with a strong position correlation is reconstructed from their position centroid distribution at the back focal plane of a microlens array. Experimentally, biphoton phase measurement and adaptive imaging against the disturbance of a plastic film are demonstrated. This single-shot method is a more direct and efficient approach toward quantum adaptive optics, suitable for integration into quantum microscopy, remote imaging, and communication.

arXiv:2504.21573•Light Science & Applications•Sep 8, 2025•9 citations

Axial localization enabled by quantum correlations

Yiqian Yang, Yunhui Gao, Liangcai Cao

Accurate axial localization is essential for identifying the object position along the optical axis, which directly impacts the resolution and fidelity of image reconstruction. However, conventional localization techniques rely on first-order intensity measurements and numerical propagation based on image sharpness metrics, making them susceptible to noise and diffraction-induced artifacts. Here, we propose a quantum correlation based axial localization method enabled by entangled photon pairs, where the axial position is encoded in the correlation peak width. In contrast to classical intensity-based approaches, the proposed method exploits second-order correlations and operates independently of the imaging modality and specimen. We analyze the evolution of the correlation peak width with defocus and show that it provides a direct and reliable indicator of the axial position. The proposed approach demonstrates enhanced noise robustness and avoids computationally intensive optimization procedures. This physics-driven framework enables robust axial localization in lensless, noninvasive, and photon-limited imaging scenarios and holds potential for advancing high-fidelity quantum imaging systems.

Applied Physics Letters•Jun 15, 2026•0 citations

Quantum-assisted sensorless adaptive optics for imaging

Patrick Cameron, Daniele Faccio, Hugo Defienne

Performance of sensorless adaptive optics strongly relies on the choice of an adequate image metric. Illumination with photon pairs provides direct access to the PSF of the system, allowing for efficient optimisation for aberration correction.

Imaging and Applied Optics•Jan 1, 2022•1 citation

Wavefront correction of high-dimensional two-photon states via coherence-entanglement transfer

Shaurya Aarav, Hugo Defienne

Reliable transmission of quantum optical states through real-world environments is key for quantum communication and imaging. Yet, aberrations and scattering in the propagation path can scramble the transmitted signal and hinder its use. A typical strategy is to employ a classical beacon beam to learn and then correct for the wavefront distortions. However, relying on a separate light source increases the overhead in the experimental apparatus. Moreover, the beacon light must closely match the non-classical state in polarization, wavelength, and even temporal bandwidth, which is highly challenging in practice. Here, we introduce a fast and efficient wavefront correction approach where we use the quantum state itself to correct for optical distortion. Via pump shaping, we control the degree of entanglement in the spatially-entangled two-photon state so that it behaves either as a high-dimensional entangled state or as a classical coherent state. The latter case is used to efficiently measure the transmission matrix of the propagation channel and correct its distortions with a spatial light modulator, thereby enabling the transmission of the high-dimensional entangled state with minimal errors. Our approach paves the way for the practical implementation of quantum imaging and communication protocols based on high-dimensional spatially entangled states.

arXiv:2509.04170•Optica Quantum•May 18, 2026•2 citations

Phase retrieval enhanced by quantum correlation

Giuseppe Ortolano, Pauline Boucher, Ivano Ruo Berchera +2 more

Quantum correlation, such as entanglement and squeezing have shown to improve phase estimation in interferometric setups on one side, and non-interferometric imaging scheme of amplitude object on the other. In the last case, quantum correlation among a pair of beams leads to a sub-shot-noise readout of the image intensity pattern, where weak details, otherwise hidden in the noise, can be appreciated. In this paper we propose a technique which exploits entanglement to enhance quantitative phase retrieval of an object in a non-interferometric setting, i.e only measuring the propagated intensity pattern after interaction with the object. The method exploits existing technology, it operates in wide field mode, so does not require time consuming raster scanning and can operate with small spatial coherence of the incident field. This protocol can find application in optical microscopy and X-ray imaging, reducing the photon dose necessary to achieve a fixed signal-to-noise ratio.

arXiv:2109.10095•Sep 21, 2021•0 citations

Adaptive optics for quantum technologies

Andrew Forbes

Adaptive optics in the classical realm usually implies some pre- or post-channel correction to an optical wavefront, with the objective to improve some figure of merit, perhaps transmission through noise, beam quality of high-power lasers, or bit-error-rate in optical communications. A measurement is performed on the beam, often wavefront sensing of the beam to be corrected, the error specified and fixed, either deterministically or by some iterative approach. In the quantum realm it is rather different. First, quantum communication demands low light levels, ideally single photons, so that compensating for lost signal by increasing power is not possible. Second, a measurement of the quantum state destroys the state, and unfortunately it is not possible to clone a quantum state (imperfect cloning is possible). This poses a conundrum: to fix the error one must measure the state, but if you measure the state the information of the state is destroyed. You know what is wrong, but have nothing left to fix. How then can AO be translated to the quantum realm? In this chapter we will answer this question, and in doing so widen the scope of adaptive optics to cases where there is no single beam of light but rather non-local quantum correlations between entangled photons.

CRC Press eBooks•Jul 10, 2024•0 citations
Adaptive optics (AO) is central to high-resolution microscopy, yet conventional implementations often require repeated correction-and-measurement cycles whose number increases with aberration complexity. This measurement burden can become prohibitive when the available temporal window for correction is short or when photon budgets are constrained. Here, we demonstrate an AO strategy that exploits the spatial correlations of entangled photon pairs to retrieve aberrations directly. By using the second-order correlation function as an aberration-sensitive metric, the required correction can be determined with only a few measurements, without relying on image-based feedback or iterative optimization. This correlation-based approach establishes an efficient framework for AO leveraging quantum light, offering a new route toward quantum-enhanced microscopy in regimes where conventional correction strategies become challenging.
The paper addresses whether spatial correlations of entangled photon pairs can support adaptive-optics aberration retrieval with fewer hardware measurements than iterative sensorless correction. For strongly position-anticorrelated pairs, assuming shift-invariant imaging and sufficiently limited aberration complexity, the sum-coordinate projection of the coincidence function satisfies C+∝∣h∗h∣2C^+\propto|h*h|^2C+∝∣h∗h∣2, independently of the object’s spatial structure. Known pupil-plane phase perturbations provide magnitude constraints for computationally retrieving this effective response and extracting a corrective phase.
The method uses 3–5 perturbations in simulations and experiments. Acquisition avoids iterative hardware optimization, but reconstruction uses an iterative phase-retrieval algorithm, supplemented by multiple response estimates and singular-value decomposition to handle noise. Experiments generate approximately 810-nm photon pairs using a 405-nm-pumped, 0.5-mm BBO crystal and measure correlations with a 32×6432\times6432×64-pixel SPAD array. Five random SLM masks enable correction of imposed defocus/astigmatism and speckle-like aberrations, restoring a concentrated correlation peak. Imaging an insect specimen demonstrates recovery of major spatial features after correction; fine-detail recovery remains incomplete because weaker illumination at the pupil periphery limits phase estimation there.
The stated applicability constraints are the need to preserve strong correlations at the object and long acquisition times. Aberrations in the illumination path can weaken those correlations, complicating use in embedded specimens. Each correlation image currently requires over 10710^7107 frames and several hours, precluding real-time correction. Faster detectors and brighter sources are proposed routes to shorter acquisitions, rather than demonstrated capabilities of this implementation.
Quantum imaging with spatially entangled photons offers advantages such as enhanced spatial resolution, robustness against noise, and counterintuitive phenomena, while a biphoton spatial aberration generally degrades its performance. Biphoton aberration correction has been achieved by using classical beams to detect the aberration source or scanning the correction phase on biphotons if the source is unreachable. Here, a new method named position-correlated biphoton Shack-Hartmann wavefront sensing is introduced, where the phase pattern added on photon pairs with a strong position correlation is reconstructed from their position centroid distribution at the back focal plane of a microlens array. Experimentally, biphoton phase measurement and adaptive imaging against the disturbance of a plastic film are demonstrated. This single-shot method is a more direct and efficient approach toward quantum adaptive optics, suitable for integration into quantum microscopy, remote imaging, and communication.
Accurate axial localization is essential for identifying the object position along the optical axis, which directly impacts the resolution and fidelity of image reconstruction. However, conventional localization techniques rely on first-order intensity measurements and numerical propagation based on image sharpness metrics, making them susceptible to noise and diffraction-induced artifacts. Here, we propose a quantum correlation based axial localization method enabled by entangled photon pairs, where the axial position is encoded in the correlation peak width. In contrast to classical intensity-based approaches, the proposed method exploits second-order correlations and operates independently of the imaging modality and specimen. We analyze the evolution of the correlation peak width with defocus and show that it provides a direct and reliable indicator of the axial position. The proposed approach demonstrates enhanced noise robustness and avoids computationally intensive optimization procedures. This physics-driven framework enables robust axial localization in lensless, noninvasive, and photon-limited imaging scenarios and holds potential for advancing high-fidelity quantum imaging systems.
Reliable transmission of quantum optical states through real-world environments is key for quantum communication and imaging. Yet, aberrations and scattering in the propagation path can scramble the transmitted signal and hinder its use. A typical strategy is to employ a classical beacon beam to learn and then correct for the wavefront distortions. However, relying on a separate light source increases the overhead in the experimental apparatus. Moreover, the beacon light must closely match the non-classical state in polarization, wavelength, and even temporal bandwidth, which is highly challenging in practice. Here, we introduce a fast and efficient wavefront correction approach where we use the quantum state itself to correct for optical distortion. Via pump shaping, we control the degree of entanglement in the spatially-entangled two-photon state so that it behaves either as a high-dimensional entangled state or as a classical coherent state. The latter case is used to efficiently measure the transmission matrix of the propagation channel and correct its distortions with a spatial light modulator, thereby enabling the transmission of the high-dimensional entangled state with minimal errors. Our approach paves the way for the practical implementation of quantum imaging and communication protocols based on high-dimensional spatially entangled states.
Quantum correlation, such as entanglement and squeezing have shown to improve phase estimation in interferometric setups on one side, and non-interferometric imaging scheme of amplitude object on the other. In the last case, quantum correlation among a pair of beams leads to a sub-shot-noise readout of the image intensity pattern, where weak details, otherwise hidden in the noise, can be appreciated. In this paper we propose a technique which exploits entanglement to enhance quantitative phase retrieval of an object in a non-interferometric setting, i.e only measuring the propagated intensity pattern after interaction with the object. The method exploits existing technology, it operates in wide field mode, so does not require time consuming raster scanning and can operate with small spatial coherence of the incident field. This protocol can find application in optical microscopy and X-ray imaging, reducing the photon dose necessary to achieve a fixed signal-to-noise ratio.
Adaptive optics in the classical realm usually implies some pre- or post-channel correction to an optical wavefront, with the objective to improve some figure of merit, perhaps transmission through noise, beam quality of high-power lasers, or bit-error-rate in optical communications. A measurement is performed on the beam, often wavefront sensing of the beam to be corrected, the error specified and fixed, either deterministically or by some iterative approach. In the quantum realm it is rather different. First, quantum communication demands low light levels, ideally single photons, so that compensating for lost signal by increasing power is not possible. Second, a measurement of the quantum state destroys the state, and unfortunately it is not possible to clone a quantum state (imperfect cloning is possible). This poses a conundrum: to fix the error one must measure the state, but if you measure the state the information of the state is destroyed. You know what is wrong, but have nothing left to fix. How then can AO be translated to the quantum realm? In this chapter we will answer this question, and in doing so widen the scope of adaptive optics to cases where there is no single beam of light but rather non-local quantum correlations between entangled photons.