arXiv:2609.26936
Coherence-Enhanced Spatial Quantum Thermometry
Asghar Ullah, Giovanni Scala, Luis L. Sánchez-Soto, Özgür E. Müstecaplıoğlu
Abstract
Quantum thermometry has long promised sensitivities beyond classical limits, with recent paradigms highlighting quantum coherence as a primary driver of precision. While most studies focus on single-point temperature estimation, we extend this framework to the spatial domain. We consider a probe two-level system (TLS) coupled asymmetrically to an auxiliary TLS that equilibrates with a sample of profile T(x). The reduced probe state carries coherence in its local basis that remains temperature-sensitive after the probe transition has frozen out, yielding a Fisher information exponentially larger at low temperature than that of a population-only readout. An exact reparametrization converts the thermometric precision into a local spatial distinguishability bound; its validity requires only a sufficiently small relative temperature uncertainty and yields an explicit measurement budget. Adding auxiliary TLSs shifts the array's optimal working temperature upward and broadens the useful sensing window, with the achievable gain ultimately limited by the total available coupling rather than by an indefinite scaling law. Finally, we propose a microwave Mach-Zehnder interferometer that maps the temperature-dependent probe coherence onto an experimentally accessible quadrature observable.
AI Summary
The paper asks how coherence-assisted qubit thermometry translates into local spatial discrimination along a temperature profile $T(x)$. It studies a probe TLS coupled to a bath-contacting auxiliary TLS through $\hbar g\sigma_z^{(a)}\sigma_x^{(p)}$, assuming global Gibbs equilibration. Exact diagonalization and partial tracing give the probe state and its temperature quantum Fisher information (QFI), benchmarked against local-basis dephasing. When the probe transition is thermally frozen but the smaller auxiliary gap remains active, temperature information survives in probe coherence. In this regime, $\mathcal F_T\simeq \sin^2\varphi\,\vartheta_a^2\operatorname{sech}^2\vartheta_a/T^2$, with $\vartheta_a=\hbar\omega_a/(2k_BT)$, producing a sensitivity peak at $k_BT\simeq0.242\hbar\omega_a$ and an exponential advantage over population-only readout. For a calibrated profile, exact QFI reparametrization yields $\mathcal F_x=[T'(x)]^2\mathcal F_T$ and the local bound $\Delta x\geq1/(|T'|\sqrt{\nu\mathcal F_T})$. Linear, quadratic and hotspot profiles illustrate this conversion. For multiple identical auxiliaries, exact collective-sector sums connect finite-size gains to interaction-renormalized gaps. Increasing auxiliary number shifts the optimal temperature upward; enhancement saturates around $N\sim50$ for the illustrated fixed per-auxiliary coupling and disappears under fixed total coupling. A proposed microwave Mach–Zehnder readout compares homodyne and intensity-difference sensitivities theoretically. The spatial bound concerns local distinguishability on a known, locally invertible profile, not general profile reconstruction. Stated requirements include local equilibrium, negligible backaction, small probe footprint and small relative temperature uncertainty. Thermalization assumes ergodic global Markovian dynamics; the readout is not experimentally demonstrated.
Central claim may not hold: The relative-temperature-error condition does not by itself guarantee valid finite spatial inference for curved temperature profiles, although the exact spatial-QFI reparametrization remains correct. The quadratic and hotspot spatial-QFI peak locations cannot generally be obtained by solving T(x)=T_max because the spatial gradient also varies with position. The peak relative-uncertainty equation has an incorrect dependence on coupling, and the quoted peak Fisher-information constants do not match the stated approximation. The multiple-auxiliary temperature-optimized inverse resolutions are smaller than reported fixed-temperature inverse resolutions under the same parameters, contradicting their definition as maxima. The interferometric readout substitutes an unsupported expression for the filtered source intensity, leaving its quantitative noise and sensitivity predictions unestablished.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 14 pages,9 figures; comments are welcome