arXiv:2609.26775
Optical Ion Clock with Engineered Immunity to Motion-Induced Frequency Shifts
Mark Lide, Wesley Hardin, Christian Sanner
Abstract
Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from $1.3\times10^{-18}$ to $0.3\times10^{-18}$. An interleaved optical frequency ratio measurement against ytterbium's electric quadrupole transition (E2) at 435 nm delivers an E3/E2 frequency ratio of $0.932 \,829 \,404 \,530 \,965 \, 340 (39)$. Combined with previously published ratio data this leads to a limit for a potential fractional temporal variation of the fine-structure constant of $2.4 (2.7) \times 10^{-19}/$yr, in agreement with existing bounds.
AI Summary
Residual motional heating during interrogation causes second-order Doppler and quadratic Stark shifts in trapped-ion clocks. Cancellation through a “magic” trap-drive frequency requires negative differential polarizability. This paper instead uses engineered Ramsey interrogation to suppress these shifts without that sign requirement. Intentionally detuned composite pulses convert the motion-dependent carrier Rabi frequency into an additional clock shift. A partially phase-inverted $3\pi/2$ preparation pulse followed by a $\pi/2$ readout pulse produces a first-order antishift matched to the accumulated Doppler and Stark shifts. The detuning is calculated from trap and interrogation parameters rather than the heating rate. Two-level calculations and interleaved spectroscopy implement and assess the protocol on the $467$ nm electric-octupole transition of a single $^{171}\mathrm{Yb}^{+}$ ion. The evaluated fractional motional uncertainty falls from $1.3\times10^{-18}$ to $0.3\times10^{-18}$; inferred non-interleaved stability is $2.1\times10^{-15}/\sqrt{\tau}$. A related motion-sensitive sequence measures heating at $180\pm15$ quanta/s, consistent with an independent $183\pm5$ quanta/s measurement. An interleaved E3/E2 measurement gives a frequency ratio of $0.932829404530965340(39)$, limited mainly by E2 systematics. Combining it with previous data yields $\dot\alpha/\alpha=2.4(2.7)\times10^{-19}\,\mathrm{yr}^{-1}$, consistent with zero and not tighter than the previous bound. Cancellation assumes linear heating and dimensional thermal equilibrium, is only first order, and does not suppress excess micromotion. Residual uncertainties include Rabi-frequency control and motional-model approximations; other systematics dominate the demonstrated clock’s total uncertainty.
Error found: The reported reduction of motional fractional uncertainty to 0.3×10^-18 is supported by modeled uncertainty intervals, while the experimental results do not directly quantify suppression of the clock frequency shift versus heating rate. Equation (2) incorrectly prints the carrier Debye–Waller factor as exp(-η/2) instead of exp(-η²/2), and its stated expansion omits the zero-point term without specifying a compensating Rabi-frequency redefinition.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments