arXiv:2609.26674
Fluctuation-Driven Nonlinear Amplification of Quantum Statistics
Yuewei Song, Zhenghe Zhou, Shuai Wan, Hecheng Wang, Jinpeng Li, Bowen Liu, Yinhai Li, Chunhua Dong, Guangcan Guo, Chong Wang, Zhiyuan Zhou, Baosen Shi
Abstract
Photon statistics have moved to the forefront of modern optics, as intensity fluctuations and correlations shape multiphoton interactions and reveal information beyond mean-intensity measurements. Developing high-quality photon sources with pronounced correlations is a fundamental necessity in these fields. Here we demonstrate fluctuation-driven nonlinear statistical amplification of quantum light in spontaneous four-wave mixing using filtered amplified spontaneous emission (ASE). Extending the coherent-pump framework to fluctuating fields, we show how nonlinear weighting of pump intensity combines with bosonic bunching to amplify quantum statistics and reshape temporal correlations. In a SiN microring, ASE pumping increases the zero-delay unconditional second-order correlation from 2.01 to 7.58 and extends the Hanbury Brown--Twiss correlation time by a factor of approximately 2.4. The super-bunched quantum source nevertheless retains heralded single-photon behaviour with $g_H^{(2)}(0)\simeq0.04$, while the same ASE pump supports time--energy entanglement in a silicon waveguide with a raw Franson visibility of 89.84\%. These results establish driving-field statistics as a design dimension for quantum light, broadening the horizons for research into higher-order correlations and nonlinear physics.
AI Summary
The paper investigates how fluctuating pump statistics reshape photon correlations in spontaneous four-wave mixing (SFWM), rather than merely changing the average pair-generation rate. It combines a low-gain stochastic-pump theory with measurements using narrowly filtered amplified spontaneous emission (ASE) in a SiN microring and a silicon waveguide. The theory separates the generated field’s HBT correlation into pump-driven flux fluctuations and bosonic exchange, including the finite cavity response. For a single detected mode and a slowly varying pump, it predicts $g_u^{(2)}(0)=2\langle I_p^4\rangle/\langle I_p^2\rangle^2$, reaching 12 for an ideal single-mode thermal pump. Experimentally, ASE with pump $g^{(2)}(0)=1.78$ increases the microring signal’s unconditional correlation from $2.01\pm0.02$ under coherent pumping to $7.58\pm0.04$. The effective HBT linewidth decreases from $141.50\pm4.15$ to $58.98\pm0.39$ MHz, corresponding to approximately 2.4 times longer correlations, not equivalent optical spectral narrowing. Heralded antibunching reaches $g_H^{(2)}(0)\simeq0.04$ at low generation rates; increasing brightness increases multipair contamination. In the separate waveguide experiment, ASE gives a fitted pair-generation coefficient approximately 1.72 times the coherent-pump value and raw Franson visibility of $89.84\pm0.40\%$. The quantitative microring comparison uses effective pump and detected-mode models, including an incoherent interpretation of two fitted temporal components whose physical origin is not established. The treatment assumes low gain. Entanglement is demonstrated in the waveguide, where the pump–photon coherence-time hierarchy is more favorable than in the microring.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.