Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.25714

Enhanced Atomic Magnetometry with a Pinched Spin State

Tingxuan Guo, Xiangyu Li, Yang Li, Kaifeng Zhao

quant-phSubmitted Sep 22, 2026• Announced Sep 23, 2026• 0 citations
arXivHTMLPDF

Abstract

The sensitivity of an atomic spin sensor is fundamentally constrained by the quantum Fisher information (QFI) of the probe state. The pinched state, $|{F,0}\rangle$, has an $(F+1)$-fold larger single-particle QFI for transverse-field sensing than the stretched state, $|{F,F}\rangle$, corresponding to a predicted $\sqrt{F+1}$ reduction in the spin-projection-noise-limited field uncertainty. We show that this advantage can be accessed in an rf sensing scheme by engineering a spectrum symmetric about $m=0$, yielding an ideal $(F+1)$-fold enhancement of magnetic-field response. For $^{87}\mathrm{Rb}$ with $F=2$, we observe up to 2.7-fold response enhancement. Implementing this approach in a compact $0.8~\mathrm{cm}^3$ anti-relaxation-coated multipass cell, we realize a single-beam, dual-axis, zero-field magnetometer, achieving $13$--$23$~$\mathrm{fT}/\sqrt{\mathrm{Hz}}$ over $3$--$100$~Hz at room temperature.

AI Summary

The paper asks how the higher single-particle quantum Fisher information of the integer-spin state $|F,0\rangle$ can be converted into measurable magnetometer response without interatomic entanglement. This “pinched” state has $F+1$ times the transverse-rotation QFI of a stretched state, implying a potential $\sqrt{F+1}$ reduction in spin-projection-noise-limited field uncertainty. The proposed rf protocol uses a quadratic Hamiltonian $H_0=\hbar\Omega_{\mathrm{TS}}F_z^2$, making both $m=0\leftrightarrow\pm1$ transitions resonant with the two circular components of a transverse rf field. A phenomenological master-equation treatment predicts an $F+1$ enhancement of the transverse-spin response for weak driving, equal relaxation rates and matched resonance frequencies. Experiments with $^{87}\mathrm{Rb}$, $F=2$, use optical pumping and tensor light shifts to obtain a response enhancement of $2.7\pm0.1$, versus the ideal factor of 3, decreasing to about 2.4 at higher resonance frequencies. A single-beam implementation in a $0.8\,\mathrm{cm}^3$ coated multipass vapor cell provides dual-axis zero-field sensing at $23\,^{\circ}\mathrm{C}$, with baseline sensitivities of $13$–$23\,\mathrm{fT}/\sqrt{\mathrm{Hz}}$ across 3–100 Hz, excluding narrow technical lines. Estimated photon-shot-noise and spin-projection-noise limits are respectively 6 and $4\,\mathrm{fT}/\sqrt{\mathrm{Hz}}$ at resonance. The predicted projection-noise-limited advantage is not directly demonstrated. Reported limitations include imperfect state preparation when one beam supplies both pumping and splitting, optical-pumping-dominated linewidths, greater spin-exchange susceptibility than the stretched state, and excess noise consistent with shield magnetic noise and probe-induced noise.

No sign of AI-generated text

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
5 pages, 5 figures

Related papers

Dual-Axis Closed Loop of a Single-Beam Atomic Magnetometer: Toward High Bandwidth and High Sensitivity

Junjian Tang, Yueyang Zhai, Binquan Zhou +2 more

Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2021•95 citations

Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

Yibo Qi, Bo Li, Shuying Wang +3 more

Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz$^{1/2}$) was 1.89 times that of the single-pass configuration (3.4 fT/Hz$^{1/2}$), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•18 citations

Zero-field atomic magnetometer to extract longitudinal magnetic field

Shuying Wang, Jixi Lu, Kaixuan Zhang +3 more

Zero-field atomic ensembles enable the development of ultrahigh-sensitivity magnetometry. However, their intrinsic insensitivity to longitudinal magnetic fields along the pumping direction poses a fundamental limitation, restricting precise weak-field quantification and complex system decoupling. Herein, we propose a novel zero-field weak parametric modulation scheme capable of ultrahigh-sensitivity extraction of longitudinal magnetic fields. Transverse modulation is employed to manifest the electron spin polarization projection induced by the longitudinal fields. Based on the perturbation model established, first-order parametric resonance associated with the longitudinal magnetic field yields significant signal enhancement under low-frequency and weak modulation conditions, while simultaneously suppressing spin-exchange relaxation caused by magnetic field modulation. We experimentally achieved a longitudinal measurement sensitivity of 16 fT / Hz 1 / 2 , more than an order of magnitude improved over traditional schemes, with a bandwidth of 70 Hz. Benefiting from low spin relaxation, the noise floor of the transverse magnetic field measurement is preserved at 4 fT / Hz 1 / 2 . The proposed scheme pushes the boundaries of existing weak magnetic field measurement, providing critical capabilities for state-of-the-art precision experiments including new physical quantity detection.

Physical Review Research•Jul 18, 2025•8 citations

Ultracold Atomic Magnetometry: Towards Quantum-Limited Sensing

Sula, Sindi

This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.

•Oct 28, 2025•0 citations

An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer

Shengran Su, Zhen-Yuan Xu, Xiang He +6 more

Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.

Sensors•Mar 15, 2023•16 citations

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu +2 more

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

Physical Review Letters•Aug 27, 2024•25 citations
The sensitivity of an atomic spin sensor is fundamentally constrained by the quantum Fisher information (QFI) of the probe state. The pinched state, ∣F,0⟩|{F,0}\rangle∣F,0⟩, has an (F+1)(F+1)(F+1)-fold larger single-particle QFI for transverse-field sensing than the stretched state, ∣F,F⟩|{F,F}\rangle∣F,F⟩, corresponding to a predicted F+1\sqrt{F+1}F+1​ reduction in the spin-projection-noise-limited field uncertainty. We show that this advantage can be accessed in an rf sensing scheme by engineering a spectrum symmetric about m=0m=0m=0, yielding an ideal (F+1)(F+1)(F+1)-fold enhancement of magnetic-field response. For 87Rb^{87}\mathrm{Rb}87Rb with F=2F=2F=2, we observe up to 2.7-fold response enhancement. Implementing this approach in a compact 0.8 cm30.8~\mathrm{cm}^30.8 cm3 anti-relaxation-coated multipass cell, we realize a single-beam, dual-axis, zero-field magnetometer, achieving 131313--232323~fT/Hz\mathrm{fT}/\sqrt{\mathrm{Hz}}fT/Hz​ over 333--100100100~Hz at room temperature.
The paper asks how the higher single-particle quantum Fisher information of the integer-spin state ∣F,0⟩|F,0\rangle∣F,0⟩ can be converted into measurable magnetometer response without interatomic entanglement. This “pinched” state has F+1F+1F+1 times the transverse-rotation QFI of a stretched state, implying a potential F+1\sqrt{F+1}F+1​ reduction in spin-projection-noise-limited field uncertainty.
The proposed rf protocol uses a quadratic Hamiltonian H0=ℏΩTSFz2H_0=\hbar\Omega_{\mathrm{TS}}F_z^2H0​=ℏΩTS​Fz2​, making both m=0↔±1m=0\leftrightarrow\pm1m=0↔±1 transitions resonant with the two circular components of a transverse rf field. A phenomenological master-equation treatment predicts an F+1F+1F+1 enhancement of the transverse-spin response for weak driving, equal relaxation rates and matched resonance frequencies. Experiments with 87Rb^{87}\mathrm{Rb}87Rb, F=2F=2F=2, use optical pumping and tensor light shifts to obtain a response enhancement of 2.7±0.12.7\pm0.12.7±0.1, versus the ideal factor of 3, decreasing to about 2.4 at higher resonance frequencies.
A single-beam implementation in a 0.8 cm30.8\,\mathrm{cm}^30.8cm3 coated multipass vapor cell provides dual-axis zero-field sensing at 23 ∘C23\,^{\circ}\mathrm{C}23∘C, with baseline sensitivities of 131313–23 fT/Hz23\,\mathrm{fT}/\sqrt{\mathrm{Hz}}23fT/Hz​ across 3–100 Hz, excluding narrow technical lines. Estimated photon-shot-noise and spin-projection-noise limits are respectively 6 and 4 fT/Hz4\,\mathrm{fT}/\sqrt{\mathrm{Hz}}4fT/Hz​ at resonance.
The predicted projection-noise-limited advantage is not directly demonstrated. Reported limitations include imperfect state preparation when one beam supplies both pumping and splitting, optical-pumping-dominated linewidths, greater spin-exchange susceptibility than the stretched state, and excess noise consistent with shield magnetic noise and probe-induced noise.
Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz1/2^{1/2}1/2) was 1.89 times that of the single-pass configuration (3.4 fT/Hz1/2^{1/2}1/2), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
Zero-field atomic ensembles enable the development of ultrahigh-sensitivity magnetometry. However, their intrinsic insensitivity to longitudinal magnetic fields along the pumping direction poses a fundamental limitation, restricting precise weak-field quantification and complex system decoupling. Herein, we propose a novel zero-field weak parametric modulation scheme capable of ultrahigh-sensitivity extraction of longitudinal magnetic fields. Transverse modulation is employed to manifest the electron spin polarization projection induced by the longitudinal fields. Based on the perturbation model established, first-order parametric resonance associated with the longitudinal magnetic field yields significant signal enhancement under low-frequency and weak modulation conditions, while simultaneously suppressing spin-exchange relaxation caused by magnetic field modulation. We experimentally achieved a longitudinal measurement sensitivity of 16 fT / Hz 1 / 2 , more than an order of magnitude improved over traditional schemes, with a bandwidth of 70 Hz. Benefiting from low spin relaxation, the noise floor of the transverse magnetic field measurement is preserved at 4 fT / Hz 1 / 2 . The proposed scheme pushes the boundaries of existing weak magnetic field measurement, providing critical capabilities for state-of-the-art precision experiments including new physical quantity detection.
This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.