arXiv:2609.25598
Efficient Ion-Photon Quantum Interface with Long-Working-Distance Exceeding 26 mm
Jungwoo Choi, Inhyuk Oh, Chanyang Im, Gibeom Son, Junki Kim
Abstract
Trapped-ion quantum networks rely on efficient ion-photon interfaces, while objective-based free-space collection systems must balance high photon collection with sufficient working distance for practical integration with ion-trap hardware. Here, we design and characterize an ion-photon interface with a long working distance of 26.15 mm and a high numerical aperture of 0.5. The core of the interface is a photon-collection objective consisting of six commercial spherical lenses with optimized spacing. The interface achieved an overall fiber-coupled photon-detection efficiency of (1.29$\pm$0.09)% from the ion to the detector and maintains fiber coupling over several hours without active realignment, supporting stable operation of the ion-to-fiber interface. Photon-correlation measurements show clear antibunching in the fiber-coupled fluorescence, confirming the preservation of non-classical photon statistics. These results demonstrate a practical implementation of a long-working-distance photon collection interface for trapped-ion quantum network experiments.
AI Summary
The paper addresses the trade-off between numerical aperture and working distance in free-space trapped-ion photon collection, aiming to support single-mode-fiber delivery without recessed viewports or in-vacuum objectives. It implements a $493\,\mathrm{nm}$ collection objective using six commercial spherical lenses with optimized spacings, providing object-space $\mathrm{NA}=0.5$ and $26.15\,\mathrm{mm}$ mechanical working distance in a trapped $^{138}\mathrm{Ba}^{+}$ apparatus. The lens prescription is provided. Ray-tracing predicts an RMS spot radius of $1.544\,\mu\mathrm{m}$ and maximum fiber coupling of $73.9\%$. Through-focus fluorescence images and fiber-position scans are consistent with near-diffraction-limited focusing; measured scan radii are $2.8$ and $2.4\,\mu\mathrm{m}$ versus $2.3\,\mu\mathrm{m}$ simulated. Peak measured fiber coupling is $(41.9\pm3.0)\%$, giving overall ion-to-detector efficiency through the fiber of $(1.29\pm0.09)\%$. This combines coupling measurements with a free-space detection efficiency of $(3.09\pm0.04)\%$, inferred from simultaneous fits of fluorescence power scans to a three-level optical Bloch model. Fiber-coupled fluorescence shows antibunching with $g^{(2)}(0)=0.042$. Without realignment, the signal stays above $80\%$ of its initial value for $58$ minutes and reaches $60\%$ after $231$ minutes. Stated limitations include factor-of-three coupling variation among three nominally identical assemblies, with results reported for the best; camera resolution insufficient for quantitative focal-plane PSF measurement; and incomplete phase/aberration characterization by fiber scanning. Additional aberrations, fiber-mode uncertainty, alignment errors, and drift are identified as possible explanations for coupling below the simulated value.
A large language model (LLM) was used to assist with language editing and improve the clarity of the manuscript.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 14 pages, 6 figures, 2 tables