arXiv:2609.25245
A dual-region ytterbium tweezer apparatus with an in-vacuum nanofiber cavity
Shunichiro Hashimoto, Hideki Ozawa, Yusuke Hisai, Takao Aoki, Ryotaro Inoue
Abstract
We present a dual-region experimental apparatus for trapping single atoms of the fermionic isotope ytterbium-171 (${}^{171}\mathrm{Yb}$) with optical tweezers in a science chamber containing an in-vacuum nanofiber cavity. A source region is located approximately $240\,\mathrm{mm}$ from the science chamber, preserving optical access around the chamber for high-numerical-aperture tweezer optics. A pulsed transport sequence based on longitudinal moving molasses launches atomic pulses toward the science chamber, where they are decelerated and recaptured in a magneto-optical trap. We subsequently load single atoms into a $2\times2$ tweezer array located approximately $50\,\mathrm{μm}$ from the nanofiber and measure a $1/e$ lifetime of $9.5(7)\,\mathrm{s}$. These results demonstrate that the dual-region architecture provides sufficient ${}^{171}\mathrm{Yb}$ atoms for single-atom tweezer operation near an in-vacuum nanofiber cavity.
AI Summary
The paper addresses how to supply ytterbium atoms to optical tweezers in a chamber containing an in-vacuum nanofiber cavity while preserving optical access and limiting exposure of the photonic device to untrapped atoms. It describes a dual-region ${}^{171}\mathrm{Yb}$ apparatus with the source approximately $240\,\mathrm{mm}$ from the science chamber. Atoms are collected in a permanent-magnet $399\,\mathrm{nm}$ 2D-MOT, launched using frequency-swept longitudinal moving molasses, propagated ballistically, and decelerated before recapture in a $556\,\mathrm{nm}$ 3D-MOT. Fluorescence measurements characterize delivery versus launch timing, source-beam detunings, and intensities. An operating point near a $1.2\,\mathrm{ms}$ launch and $12\,\mathrm{ms}$ flight delivers up to $4.0\times10^3$ atoms per pulse, using $20\,\mathrm{mW}$ of transverse cooling power and $15\,\mathrm{mW}$ of slowing power. The delivered atoms load a $2\times2$ array of $759\,\mathrm{nm}$ tweezers approximately $50\,\mathrm{\mu m}$ from the nanofiber. Site-resolved fluorescence gives a single-atom filling fraction of $66.4(5)\%$ under the reported conditions; further optimization in the same apparatus yielded $74.9(7)\%$. An exponential fit to survival measurements gives a lifetime of $9.5(7)\,\mathrm{s}$. Across two implementations, cavities initially having intrinsic finesse around $10^3$ showed no significant decrease during routine loading over months or longer. The available blue-light power limits the source characterization: delivered atom number continues increasing throughout the tested intensity range. The demonstration is limited to four tweezers; atom–photon coupling is reported separately, rather than established here.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.