arXiv:2609.22937 · Physical Review Materials

Efficient creation of shallow NV$^-$ ensembles by high-angle ion implantation

Kento Sasaki, Hideyuki Watanabe, Tokuyuki Teraji, Takashi Taniguchi, Kenji Watanabe, Kensuke Kobayashi

quant-phcond-mat.mtrl-sciSubmitted Sep 19, 2026• Announced Sep 22, 2026• 0 citations
arXivHTMLPDF

Abstract

Negatively charged nitrogen-vacancy (NV$^-$) centers located a few nanometers below the diamond surface are key quantum defects for nanoscale sensing of external spins. However, the creation of shallow NV$^-$ centers with high yield remains a materials challenge. Here, we demonstrate that high-angle ion implantation enhances the creation efficiency of shallow NV$^-$ centers. By implanting $^{15}$N ions at angles exceeding 60$^\circ$, we achieve high NV$^-$ yields approaching 10% with effective NV$^-$ depths below 10 nm. These yields are significantly higher than those typically reported for shallow NV$^-$ creation. The enhanced NV$^-$ yield is consistent with an increased vacancy-to-nitrogen ratio in the near-surface region, which is expected to promote NV formation during annealing. The created NV$^-$ ensembles show coherence properties comparable to those of single shallow NV$^-$ centers at similar depths, and allow detection of nuclear spins in van der Waals materials attached to the diamond surface. Our results establish geometric control of ion implantation as a simple and broadly applicable approach to engineer shallow vacancy-related quantum defects.

AI Summary

Shallow NV$^-$ ensembles enable nanoscale spin sensing, but conventional low-energy nitrogen implantation typically gives conversion yields of $0.1$–$1\%$. This paper investigates whether oblique implantation can increase the near-surface vacancy-to-nitrogen ratio while retaining shallow NV centers. The experiments implant $^{15}$N at 5 keV and angles of $60^\circ$–$85^\circ$ from the surface normal, followed by forming-gas annealing and oxygen termination. Photoluminescence calibrated against single NV centers gives yields of 7.8%, 8.3%, 4.5%, and 2.4% at $60^\circ$, $70^\circ$, $80^\circ$, and $85^\circ$, respectively, using SRIM-estimated retained nitrogen densities. Spatial-fluctuation estimates agree with these yields. SRIM predicts shallower nitrogen and vacancy distributions and an increased vacancy-to-nitrogen ratio at high angles. Detection of $^{11}$B spins in attached hBN flakes gives effective NV–hBN separations decreasing from 8.2 to 5.9 nm across the angle range. Hahn-echo coherence times increase from 2.83 to 7.20 $\mu$s; XY16 with 128 pulses extends these to 19.2–54.8 $\mu$s. Ramsey hyperfine spectra identify the ensembles as implanted $^{15}$NV$^-$ centers. The mechanism behind the yield enhancement remains unresolved. Depth estimates apply a single-NV model to ensembles and include an interfacial gap; they exceed SRIM mean depths by approximately 3 nm, more than expected from a typical hydrocarbon interlayer alone. Nitrogen density, implantation damage, and depth vary together, complicating attribution of coherence trends. Further dose increases may induce vacancy clustering or amorphization; extensions to other defect platforms remain proposed.

Little sign of AI-generated textMissing comparison

Central claim may not hold: Without a matched conventional-angle control using the same annealing and surface treatments, the paper demonstrates useful shallow NV ensembles but does not establish how much their enhanced conversion yield is caused by high-angle implantation.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Journal reference
Phys. Rev. Materials 10, 086202 (2026)
DOI
10.1103/d8vg-ntsg

Related papers

Creation of Depth-Confined, Shallow Nitrogen-Vacancy Centers in Diamond With Tunable Density

Lillian B. Hughes Wyatt, Shreyas Parthasarathy, Isaac Kantor +6 more

Engineering shallow nitrogen-vacancy (NV) centers in diamond holds the key to unlocking new advances in nanoscale quantum sensing. We find that the creation of near-surface NVs through delta doping during diamond growth allows for tunable control over both NV depth confinement (with a twofold improvement relative to low-energy ion implantation) and NV density, ultimately resulting in highly-sensitive single defects and ensembles with coherence limited by NV-NV interactions. Additionally, we demonstrate the utility of our shallow delta-doped NVs by imaging magnetism in few-layer CrSBr, a two-dimensional magnet. We anticipate that the control afforded by near-surface delta doping will enable new developments in NV quantum sensing from nanoscale NMR to entanglement-enhanced metrology.

quant-pharXiv:2512.11242•Applied Physics Letters•Dec 15, 2025•2 citations

Engineering of nitrogen-vacancy color centers in high purity diamond by ion implantation and annealing

Julius O. Orwa, Charles Santori, Kai‐Mei C. Fu +11 more

The negatively-charged nitrogen-vacancy (NV) center is the most studied optical center in diamond and is very important for applications in quantum information science. Many proposals for integrating NV centers in quantum and sensing applications rely on their tailored fabrication in ultra pure host material. In this study, we use ion implantation to controllably introduce nitrogen into high purity, low nitrogen chemical vapor deposition diamond samples. The properties of the resulting NV centers are studied as a function of implantation temperature, annealing temperature, and implantation fluence. We compare the implanted NV centers with native NV centers present deep in the bulk of the as-grown samples. The results for implanted NV centers are promising but indicate, at this stage, that the deep native NV centers possess overall superior optical properties. In particular, the implanted NV centers obtained after annealing at 2000 °C under a stabilizing pressure of 8 GPa showed an ensemble linewidth of 0.17 nm compared to 0.61 nm after annealing at 1000 °C. Over the same temperature range, the ensemble NV−/NV0 ratio increased by a factor of ∼5, although this was accompanied by an overall decrease in the NV count.

Journal of Applied Physics•Apr 15, 2011•126 citations

Optimizing ion implantation to create shallow NV centre ensembles in high-quality CVD diamond

Midrel Wilfried Ngandeu Ngambou, Pauline Perrin, Ionuț Gabriel Balașa +7 more

Abstract The negatively charged nitrogen-vacancy centre (so-called NV-centre) in diamond is one of the most promising systems for applications in quantum technologies because of the possibility to optically manipulate and read out the spin state of this defect, even at room temperature. Nevertheless, obtaining high NV densities (>500 ppb) close to the surface (5–20 nm) while maintaining good spin properties remain challenging. In this work we rely on a versatile ion implantation system allowing both implanting nitrogen using N 2 + and creating vacancies with He + ion bombardment at variable energies and fluence to create shallow NV ensembles. By optimizing the ion irradiation conditions as well as the surface preparation prior to treatment we successfully increase the amount of created colour centres while demonstrating narrow magnetic resonance linewidths.

Materials for Quantum Technology•Oct 11, 2022•14 citations

Enhanced magnetic field sensitivity of shallow NV− ensembles via high-temperature implantation

J. Al Yahya, A. Bach, J. Panigrahi +7 more

Dense and shallow ensembles of negatively charged nitrogen-vacancy center (NV−) with good optical and spin properties play a key role in the performance enhancement of diamond-based quantum sensors. Ion implantation enables precise control of NV− depth and density. However, at high ion fluence, this method is limited by low NV− creation yields and sample amorphization. Additionally, shallow NV− spin properties deteriorate due to surface proximity. In this paper, we study N2+ ion implantation at energies between 10 and 15 keV with fluences as high as 1×1015 ions/cm2 at temperatures of 20, 400, and 800°C to investigate the influence of implantation temperature on lattice damage, NV− creation yield, and NV− spin properties. Our results show that diamond maintains structural integrity at 800°C with fluences up to 1×1015 ions/cm2 without amorphization. Furthermore, high-temperature implantation improves NV− creation yields up to five times without compromising T2∗, T2, and T1, making it a promising approach to enhance the magnetic field sensitivity of NV− ensembles.

arXiv:2509.05647•Journal of Applied Physics•Dec 16, 2025•1 citation

Doping optimization of charge state stability for shallow nitrogen-vacancy center ensembles in HPHT diamonds

Qin Wu, Die Fang, Yu Ma +9 more

Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.

Applied Physics Letters•Jun 16, 2025•1 citation

Hot ion implantation to create dense NV center ensembles in diamond

Midrel Wilfried Ngandeu Ngambou, Pauline Perrin, Ionuț Gabriel Balașa +9 more

Creating dense and shallow nitrogen-vacancy (NV) ensembles with good spin properties is a prerequisite for developing diamond-based quantum sensors exhibiting better performance. Ion implantation is a key enabling tool for precisely controlling spatial localization and density of NV color centers in diamond. However, it suffers from a low creation yield, while higher ion fluences significantly damage the crystal lattice. In this work, we realize N2+ ion implantation in the 30–40 keV range at high temperatures. At 800 °C, NV's ensemble photoluminescence emission is three to four times higher than room temperature implanted films, while narrow electron spin resonance linewidths of 1.5 MHz, comparable to well-established implantation techniques, are obtained. In addition, we found that ion fluences above 2 × 1014 ions/cm2 can be used without graphitization of the diamond film, in contrast to room temperature implantation. This study opens promising perspectives in optimizing diamond films with implanted NV ensembles that could be integrated into quantum sensing devices.

arXiv:2311.05328•Applied Physics Letters•Mar 25, 2024•19 citations
Efficient creation of shallow NV−^-− ensembles by high-angle ion implantation
Negatively charged nitrogen-vacancy (NV−^-−) centers located a few nanometers below the diamond surface are key quantum defects for nanoscale sensing of external spins. However, the creation of shallow NV−^-− centers with high yield remains a materials challenge. Here, we demonstrate that high-angle ion implantation enhances the creation efficiency of shallow NV−^-− centers. By implanting 15^{15}15N ions at angles exceeding 60∘^\circ∘, we achieve high NV−^-− yields approaching 10% with effective NV−^-− depths below 10 nm. These yields are significantly higher than those typically reported for shallow NV−^-− creation. The enhanced NV−^-− yield is consistent with an increased vacancy-to-nitrogen ratio in the near-surface region, which is expected to promote NV formation during annealing. The created NV−^-− ensembles show coherence properties comparable to those of single shallow NV−^-− centers at similar depths, and allow detection of nuclear spins in van der Waals materials attached to the diamond surface. Our results establish geometric control of ion implantation as a simple and broadly applicable approach to engineer shallow vacancy-related quantum defects.
Shallow NV−^-− ensembles enable nanoscale spin sensing, but conventional low-energy nitrogen implantation typically gives conversion yields of 0.10.10.1–1%1\%1%. This paper investigates whether oblique implantation can increase the near-surface vacancy-to-nitrogen ratio while retaining shallow NV centers.
The experiments implant 15^{15}15N at 5 keV and angles of 60∘60^\circ60∘–85∘85^\circ85∘ from the surface normal, followed by forming-gas annealing and oxygen termination. Photoluminescence calibrated against single NV centers gives yields of 7.8%, 8.3%, 4.5%, and 2.4% at 60∘60^\circ60∘, 70∘70^\circ70∘, 80∘80^\circ80∘, and 85∘85^\circ85∘, respectively, using SRIM-estimated retained nitrogen densities. Spatial-fluctuation estimates agree with these yields. SRIM predicts shallower nitrogen and vacancy distributions and an increased vacancy-to-nitrogen ratio at high angles.
Detection of 11^{11}11B spins in attached hBN flakes gives effective NV–hBN separations decreasing from 8.2 to 5.9 nm across the angle range. Hahn-echo coherence times increase from 2.83 to 7.20 μ\muμs; XY16 with 128 pulses extends these to 19.2–54.8 μ\muμs. Ramsey hyperfine spectra identify the ensembles as implanted 15^{15}15NV−^-− centers.
The mechanism behind the yield enhancement remains unresolved. Depth estimates apply a single-NV model to ensembles and include an interfacial gap; they exceed SRIM mean depths by approximately 3 nm, more than expected from a typical hydrocarbon interlayer alone. Nitrogen density, implantation damage, and depth vary together, complicating attribution of coherence trends. Further dose increases may induce vacancy clustering or amorphization; extensions to other defect platforms remain proposed.
Engineering shallow nitrogen-vacancy (NV) centers in diamond holds the key to unlocking new advances in nanoscale quantum sensing. We find that the creation of near-surface NVs through delta doping during diamond growth allows for tunable control over both NV depth confinement (with a twofold improvement relative to low-energy ion implantation) and NV density, ultimately resulting in highly-sensitive single defects and ensembles with coherence limited by NV-NV interactions. Additionally, we demonstrate the utility of our shallow delta-doped NVs by imaging magnetism in few-layer CrSBr, a two-dimensional magnet. We anticipate that the control afforded by near-surface delta doping will enable new developments in NV quantum sensing from nanoscale NMR to entanglement-enhanced metrology.
The negatively-charged nitrogen-vacancy (NV) center is the most studied optical center in diamond and is very important for applications in quantum information science. Many proposals for integrating NV centers in quantum and sensing applications rely on their tailored fabrication in ultra pure host material. In this study, we use ion implantation to controllably introduce nitrogen into high purity, low nitrogen chemical vapor deposition diamond samples. The properties of the resulting NV centers are studied as a function of implantation temperature, annealing temperature, and implantation fluence. We compare the implanted NV centers with native NV centers present deep in the bulk of the as-grown samples. The results for implanted NV centers are promising but indicate, at this stage, that the deep native NV centers possess overall superior optical properties. In particular, the implanted NV centers obtained after annealing at 2000 °C under a stabilizing pressure of 8 GPa showed an ensemble linewidth of 0.17 nm compared to 0.61 nm after annealing at 1000 °C. Over the same temperature range, the ensemble NV−/NV0 ratio increased by a factor of ∼5, although this was accompanied by an overall decrease in the NV count.
Abstract The negatively charged nitrogen-vacancy centre (so-called NV-centre) in diamond is one of the most promising systems for applications in quantum technologies because of the possibility to optically manipulate and read out the spin state of this defect, even at room temperature. Nevertheless, obtaining high NV densities (>500 ppb) close to the surface (5–20 nm) while maintaining good spin properties remain challenging. In this work we rely on a versatile ion implantation system allowing both implanting nitrogen using N 2 + and creating vacancies with He + ion bombardment at variable energies and fluence to create shallow NV ensembles. By optimizing the ion irradiation conditions as well as the surface preparation prior to treatment we successfully increase the amount of created colour centres while demonstrating narrow magnetic resonance linewidths.
Dense and shallow ensembles of negatively charged nitrogen-vacancy center (NV−) with good optical and spin properties play a key role in the performance enhancement of diamond-based quantum sensors. Ion implantation enables precise control of NV− depth and density. However, at high ion fluence, this method is limited by low NV− creation yields and sample amorphization. Additionally, shallow NV− spin properties deteriorate due to surface proximity. In this paper, we study N2+ ion implantation at energies between 10 and 15 keV with fluences as high as 1×1015 ions/cm2 at temperatures of 20, 400, and 800°C to investigate the influence of implantation temperature on lattice damage, NV− creation yield, and NV− spin properties. Our results show that diamond maintains structural integrity at 800°C with fluences up to 1×1015 ions/cm2 without amorphization. Furthermore, high-temperature implantation improves NV− creation yields up to five times without compromising T2∗, T2, and T1, making it a promising approach to enhance the magnetic field sensitivity of NV− ensembles.
Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.
Creating dense and shallow nitrogen-vacancy (NV) ensembles with good spin properties is a prerequisite for developing diamond-based quantum sensors exhibiting better performance. Ion implantation is a key enabling tool for precisely controlling spatial localization and density of NV color centers in diamond. However, it suffers from a low creation yield, while higher ion fluences significantly damage the crystal lattice. In this work, we realize N2+ ion implantation in the 30–40 keV range at high temperatures. At 800 °C, NV's ensemble photoluminescence emission is three to four times higher than room temperature implanted films, while narrow electron spin resonance linewidths of 1.5 MHz, comparable to well-established implantation techniques, are obtained. In addition, we found that ion fluences above 2 × 1014 ions/cm2 can be used without graphitization of the diamond film, in contrast to room temperature implantation. This study opens promising perspectives in optimizing diamond films with implanted NV ensembles that could be integrated into quantum sensing devices.