arXiv:2609.21630
Spatially resolved quantum magnetometry and stray-field reconstruction of permalloy microdisks using boron-vacancy centers in hexagonal boron nitride
Peiting Wen, Shuyu Wen, Jiang Qu, Zeling Xiong, Katrin Schultheiss, Slawomir Prucnal, Artur Erbe, Kenji Watanabe, Takashi Taniguchi, Jürgen Lindner, Jürgen Fassbender, Manfred Helm, Shengqiang Zhou, Ruslan Salikhov, Helmut Schultheiss, Yonder Berencén
Abstract
Transferable hexagonal boron nitride (hBN) hosting negatively charged boron-vacancy (VB$^{-}$) spin defects offers a versatile platform for integrated quantum magnetometry, yet quantitative imaging of magnetic microstructures remains challenging. Here, we integrate a transferred hBN flake with a 4 $μ$m-diameter permalloy (Py = Ni${81}$Fe${19}$) microdisk and perform spatially resolved optically detected magnetic resonance measurements at room temperature. An applied in-plane magnetic field distorts the vortex-state magnetization, generating edge-localized magnetic surface charges and pronounced stray-field signatures at opposite disk edges. By referencing each pixel to its local zero-field splitting and correcting for a residual out-of-plane bias field, we quantitatively reconstruct the out-of-plane stray-field distribution, revealing peak fields of approximately 11.2 mT. An edge-charge model reproduces the spatial distribution and amplitude of the reconstructed field, linking the ODMR response to the field-driven evolution of the vortex state. These results establish transferred hBN VB$^{-}$ sensors for quantitative magnetometry of magnetic microstructures.
AI Summary
This paper addresses quantitative, spatially resolved imaging of magnetic microstructures using negatively charged boron-vacancy ($V_B^{-}$) spin defects in transferable hexagonal boron nitride (hBN). It examines whether a transferred hBN sensor can reconstruct the stray field of a permalloy microdisk and relate that field to its vortex-state magnetization. A defect-hosting hBN flake is integrated with a $4\,\mu\mathrm{m}$-diameter permalloy disk ($\mathrm{Ni}_{81}\mathrm{Fe}_{19}$), and spatially resolved optically detected magnetic resonance (ODMR) measurements are performed at room temperature. An applied in-plane field distorts the magnetic vortex, producing edge-localized magnetic surface charges and stray-field signatures at opposite disk edges. The reconstruction references each pixel to its local zero-field splitting and corrects for a residual out-of-plane bias field, yielding an out-of-plane stray-field map with peak fields of approximately $11.2\,\mathrm{mT}$. An edge-charge model reproduces the reported spatial distribution and field amplitude, providing a connection between the ODMR measurements and the field-driven deformation of the vortex state. The reported demonstration concerns the out-of-plane stray-field component of this microdisk, rather than full vector magnetometry or a general reconstruction of the internal magnetization. Only the abstract is available; it states no explicit limitations and does not provide spatial resolution, field sensitivity, sensor–sample separation, uncertainty estimates, or details of the model comparison.
Written by gpt-6.1-sol from the abstract only. Automated: it can be wrong.
- Comments
- 20 pages, 4 Fgures