arXiv:2609.19317

Observing and evading quantum back-action on a kilogram-scale oscillator

Begüm Kabagöz, Eric Oelker, Dhruva Ganapathy, Nergis Mavalvala, Vivishek Sudhir, Vladimir Bossilkov, Joseph Betzweiser, Valery V. Frolov, Anamaria Effler, Adam Mullavey, Lisa Barsotti, Evan D. Hall, Peter Fritschel, R. Abbott, I. Abouelfettouh, R. X. Adhikari, A. Ananyeva, S. Appert, S. K. Apple, K. Arai, N. Aritomi, S. M. Aston, M. Ball, S. W. Ballmer, D. Barker, B. K. Berger, D. Bhattacharjee, G. Billingsley, S. Biscans, C. D. Blair, N. Bode, E. Bonilla, A. Branch, A. F. Brooks, D. D. Brown, J. Bryant, C. Cahillane, A. Calafat, S. R. Callos, H. Cao, E. Capote, F. Clara, J. Collins, C. M. Compton, G. Connolly, R. Cottingham, D. C. Coyne, R. Crouch, J. Csizmazia, A. Cumming, L. P. Dartez, D. Davis, N. Demos, E. Dohmen, K. L. Dooley, J. C. Driggers, S. E. Dwyer, A. Ejlli, T. Etzel, M. Evans, J. Feicht, R. Frey, W. Frischhertz, M. Fuentes-Garcia, P. Fulda, M. Fyffe, B. Gateley, T. Gayer, J. A. Giaime, K. D. Giardina, J. Glanzer, E. Goetz, R. Goetz, A. W. Goodwin-Jones, S. Gras, C. Gray, D. Griffith, H. Grote, T. Guidry, J. Gurs, J. Hanks, J. Hanson, M. C. Heintze, A. F. Helmling-Cornell, N. A. Holland, D. Hoyland, H. Y. Huang, Y. Inoue, A. L. James, A. Jamies, R. Jaume, A. Jennings, W. Jia, D. H. Jones, S. Karat, S. Karki, M. Kasprzack, K. Kawabe, N. Kijbunchoo, P. J. King, J. S. Kissel, K. Komori, A. Kontos, R. Kumar, K. Kuns, M. Landry, B. Lantz, M. Laxen, K. Lee, M. Lesovsky, F. Llamas Villarreal, M. Lormand, H. A. Loughlin, R. Macas, M. MacInnis, C. N. Makarem, B. Mannix, G. L. Mansell, R. M. Martin, K. Mason, F. Matichard, N. Maxwell, G. McCarrol, R. McCarthy, D. E. McClelland, S. McCormick, T. McRae, F. Mera, E. L. Merilh, J. R. Mérou, F. Meylahn, R. Mittleman, D. Moraru, G. Moreno, M. Nakano, T. J. N. Nelson, A. Neunzert, J. Notte, J. Oberling, T. O'Hanlon, R. Oram, C. Osthelder, D. J. Ottaway, H. Overmier, W. Parker, O. Patane, A. Pele, H. Pham, M. Pirello, J. Pullin, V. Quetschke, K. E. Ramirez, K. Ransom, J. Reyes, J. W. Richardson, M. Robinson, J. G. Rollins, C. L. Romel, J. H. Romie, M. P. Ross, B. I. Rotimi, K. Ryan, T. Sadecki, A. Sanchez, E. J. Sanchez, L. E. Sanchez, R. L. Savage, D. Schaetzl, M. G. Schiworski, R. Schnabel, R. M. S. Schofield, E. Schwartz, D. Sellers, T. Shaffer, R. W. Short, D. Sigg, B. J. J. Slagmolen, C. Soike, S. Soni, V. Srivastava, L. Sun, D. B. Tanner, M. Thomas, P. Thomas, K. A. Thorne, M. R. Todd, C. I. Torrie, G. Traylor, A. S. Ubhi, G. Vajente, J. Vanosky, A. Vecchio, P. J. Veitch, A. M. Vibhute, E. R. G. von Reis, J. Warner, B. Weaver, R. Weiss, C. Whittle, B. Willke, C. C. Wipf, J. L. Wright, V. A. Xu, H. Yamamoto, L. Zhang, M. E. Zucker

quant-phgr-qcphysics.ins-detphysics.opticsSubmitted Sep 16, 2026• Announced Sep 18, 2026• 1 citation
arXivHTMLPDF

Abstract

Continuous quantum displacement measurements are fundamentally limited by a trade-off between readout imprecision and measurement back-action, constrained by the Heisenberg uncertainty principle. In the Laser Interferometric Gravitational-Wave Observatory (LIGO), these two quantum noise components dominate much of the observation band, making it an excellent testbed. We induce a sub-Hz-linewidth optomechanical mode by trapping the differential motion of the 40-kg mirrors in a band where radiation-pressure back-action dominates the motion. Engineering the quantum state entering the dark port creates correlations between imprecision and back-action that partially cancel their contributions, reducing observed motion near resonance by ~47%. A framework resolving the imprecision, back-action, and correlation terms identifies the origin of this suppression. These results demonstrate quantum back-action evasion and quantum reservoir engineering in a macroscopic optomechanical system.

AI Summary

Continuous displacement measurements combine quantum imprecision and radiation-pressure back-action; correlations can reduce their combined contribution. This paper investigates these effects in LIGO Livingston by placing the differential motion of four 40-kg mirrors, with effective mass $\sim10$ kg, inside the detector’s quantum-noise-sensitive band. Digital feedback creates a mechanical resonance near $151$ Hz with quality factor $\sim100$. With circulating power and trapping parameters fixed, displacement spectra are compared for ordinary vacuum, frequency-independent squeezing (FIS), and frequency-dependent squeezing (FDS). FIS reduces high-frequency imprecision but increases low-frequency back-action. FDS retains comparable high-frequency imprecision while reducing observed displacement-noise power near resonance by $(47\pm5)\%$ relative to vacuum and $(31\pm7)\%$ relative to FIS. A multiport interferometer model, fitted jointly across configurations, attributes the suppression to negative imprecision–back-action correlations. The decomposition uses the power dependence $S_{xx}^{\mathrm{QN}}=A/P+BP+C$ to identify imprecision, back-action, and correlation contributions. Consistent inferred classical-noise residuals across configurations support this interpretation; the decomposition is model-derived rather than obtained from an experimental power scan. The paper also interprets squeezed illumination as an engineered reservoir. Subtracting modeled imprecision and integrating the inferred motion gives equivalent occupations of $324\pm38$ for vacuum, $423\pm30$ for FIS, and $198\pm23$ for FDS. These are inferred equivalent occupations, not demonstrations of nonclassical mechanical states. The stated limitations include feedback delays and stability requirements restricting the trap quality factor, and residual classical noise—primarily coating thermal noise—contributing approximately $125$ phonons and limiting further reservoir-based state engineering.

Little sign of AI-generated textOverclaimsPossible error

Central claim may not hold: The abstract's sub-Hz linewidth conflicts with both the tabulated approximately 1.5 Hz FWHM and the approximately 1.51 Hz linewidth implied by 151 Hz divided by Q ≈ 100. Subtracting the modeled observed-imprecision spectrum from the in-loop measurement does not recover physical mechanical motion in this correlated feedback system, so the reported phonon occupations and cooling interpretation are not established by the stated estimator. The squeezed-reservoir occupation inference relies on an unjustified identification of the bath force-response susceptibility with the inverse susceptibility of the feedback-controlled mechanical oscillator.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
Main text 8 pages, 4 figures. Supplementary 10 pages, 7 figures

Related papers

Quantum Noise Engineering in Advanced LIGO

Begüm Kabagöz

Advanced LIGO is a gravitational-wave detector with extreme sensitivity, operating close to the quantum limits of optical measurement. The quantum noise in this system arises from vacuum fluctuations entering the interferometer readout port: phase-like fluctuations produce measurement imprecision, while amplitude-like fluctuations drive radiation-pressure back-action. In this review, we present an intuitive description in terms of complex fields and quadratures, and follow squeezed vacuum from its generation, through its interaction with the filter cavity and propagation through the interferometer, to the readout. We discuss how frequency-independent and frequency-dependent squeezing engineer quantum noise, and how correlations between optical quadratures map onto correlations between measurement imprecision and back-action. We conclude that LIGO is both a gravitational-wave observatory and a kilometre-scale platform for quantum measurement science.

arXiv:2611.07074•Nov 4, 2026•0 citations

Quantum Measurement of Mechanical Motion close to the Standard Quantum Limit

Liu Qiu

In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.

•Jan 1, 2020•1 citation

A parameter-matched effective negative-mass oscillator for all-optical quantum noise cancellation

Nived Johny

Advances in precision optomechanical measurement underpin a wide range of technologies, from inertial sensors to the detection of gravitational waves and the exploration of fundamental physics. For such applications, the ultimate sensitivity is limited by quantum noise: shot noise, which stems from the stochastic arrival of photons, dominates at high frequencies, while Quantum Back-Action (QBA) noise—arising from the random radiation-pressure force exerted by the light field—prevails at low frequencies. The interplay between these two contributions defines the Standard Quantum Limit (SQL) of interferometry, a power-dependent trade-off that constrains further performance improvements. Although several sub-SQL techniques have been demonstrated, they typically enhance narrow-band sensitivity or require long filter cavities. Coherent Quantum Noise Cancellation (CQNC), first proposed by Tsang and Caves, offers a broadband solution by introducing an Effective Negative-Mass Oscillator (ENMO) that destructively interferes with the QBA noise across the entire spectrum except at the mechanical resonance of the opto-mechanically coupled system. A mathematically equivalent scheme for broadband QBA evasion has been demonstrated—for example, using atomic ensembles. The operation of this scheme is restricted to specific atomic transition wavelengths and is therefore unsuitable for many optomechanical platforms. This thesis reports the first all-optical, table-top realisation of an ENMO capable of Coherent Quantum Noise Cancellation in quantum optomechanical sensors. The scheme employs an optical analogue of the optomechanical interaction, generated through a combination of parametric down-conversion and beam-splitting processes, yielding a tunable, wavelength-flexible, and compact system. The achieved parameters satisfy the CQNC targets established in earlier theoretical work, and the current system predicts a broadband quantum-noise reduction of 3.6 dB (77% suppression of QBA noise(in dB)) at the frequency of maximum suppression. With further reduction of intracavity losses, the projected cancellation improves to 11.9 dB (81% suppression (in dB)). The experimental realisation features two polarisation-coupled optical resonators that host a two-mode squeezing interaction; the optical resonators possess distinct detunings and linewidths. The interdependent nature of the ENMO system motivated the development of an in-situ characterisation method, which is essential for integrating the ENMO with an optomechanical system in practical applications. Adequately addressing the system’s complexity required the development of five specialised experimental techniques for parameter tuning and comprehensive characterisation. Beyond quantum-noise cancellation, this system lends itself to application in quantum-information and quantum-communication tasks, including an on-demand, high-purity single-photon source and a quantum memory. Owing to the optical platform’s immunity to thermal decoherence, it can be operated at room temperature, and the parametric down-conversion process affords flexibility in wavelength selection. The results presented here advance the state of the art in broadband quantum noise reduction in a broad class of optomechanical devices, with immediate relevance for emerging quantum-technology applications.

•Jan 1, 2026•0 citations

Quantum and dynamical back-action effects using a gram-scale mechanical resonator in a high-finesse optical cavity

Alexandros Tavernarakis

Cavity Optomechanics, that is the study of the interaction between an optical cavity mode and a mechanical degree of freedom, has known impressive evolution over the past decade, to become a new field at the union of condensed matter physics and optics. One of the major goals of this discipline is to test and study quantum mechanics using macroscopic systems. Among the most fundamental problems the community aims to address is the question of the quantum limits in position measurement. Quantum mechanics predicts that any measurement comes along with a backaction, which perturbs the state of the measured system. Moreover, it is expected to be conjugated with the quantum noise of the measurement apparatus (called measurement noise) used to probe the system. The optimal sensitivity is reached whenever both the measurement and the backaction noise are identical, a situation which can be assimilated to the acceptance of Heisenberg's inequality for the measurement apparatus. In cavity optomechanics, the mode of an optical cavity is used as a measurement apparatus of the position of a mechanical resonator which is expected to be responsible for the backaction imprecision. However, this so-called radiation pressure quantum backaction has never been observed to date, while it remains a decisive step towards understanding quantum measurement processes. We describe in this manuscript the study of radiation pressure effects in cavity optomechanics. We introduce the optomechanical system we have developed, which consists in a cm-scale ultra high Q (~ 1 000 000) plano-convex mechanical resonator incorporated into a ultra-high finesse (~ 300 000) Fabry-Prot cavity. We present two important results we obtained with this system. First, we were able to report the first direct observation of radiation pressure in real-time, based on establishing pump-probe correlations. We were also able to demonstrate for the first time nonlinear backaction effects related to substantial improvement of position measurement sensitivity. We explain why demonstrating quantum backaction requires ultra-high stability of the optical mode. We present important changes made to the previous experimental setup, notably on the laser source, on the detection and the stabilization of the experiment. We then describe a new optomechanical detection technique providing an independent measurement of the cavity detuning. Finally, we present a proof-of-principle experiment allowing to extract quantum optomechanical correlations at room temperature.

•Dec 20, 2012•0 citations

Advanced quantum techniques for future gravitational-wave detectors

S. L. Danilishin, Farid Ya. Khalili, Haixing Miao

Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.

arXiv:1903.05223•Living Reviews in Relativity•Apr 29, 2019•84 citations

Back-Action Evading Measurements of Nanomechanical Motion Approaching Quantum Limits

Jared Hertzberg

The application of quantum mechanics to macroscopic motion suggests many counterintuitive phenomena. While the quantum nature of the motion of individual atoms and molecules has long been successfully studied, an equivalent demonstration of the motion of a near-macroscopic structure remains a challenge in experimental physics. A nanomechanical resonator is an excellent system for such a study. It typically contains > 10 10 atoms, and it may be modeled in terms of macroscopic parameters such as bulk density and elasticity. Yet it behaves like a simple harmonic oscillator, with mass low enough and resonant frequency high enough for its quantum zero-point motion and single energy quanta to be experimentally accessible. In pursuit of quantum phenomena in a mechanical oscillator, two important goals are to prepare the oscillator in its quantum ground state, and to measure its position with a precision limited by the Heisenberg uncertainty principle. In this work we have demonstrated techniques that advance towards both of these goals. Our system comprises a 30 micron × 170 nm, 2.2 pg, 5.57 MHz nanomechanical resonator capacitively coupled to a 5 GHz superconducting microwave resonator. The microwave resonator and nanomechanical resonator are fabricated together onto a single silicon chip and measured in a dilution refrigerator at temperatures below 150 mK. At these temperatures the coupling of the motion to the thermal environment is very small, resulting in a very high mechanical Q, approaching ∼ 10 6 . By driving with a microwave pump signal, we observed sidebands generated by the mechanical motion and used these to measure the thermal motion of the resonator. Applying a pump tone red-detuned from the microwave resonance, we used the microwave field to damp the mechanical resonator, extracting energy and "cooling" the motion in a manner similar to optical cooling of trapped atoms. Starting from a mode temperature of ∼ 150 mK, we reached ∼ 40 mK by this "backaction cooling" technique, corresponding to an occupation factor only ∼ 150 times above the ground state of motion. We also determined the precision of our device in measurement of position. Quantum mechanics dictates that, in a continuous position measurement, the precision may be no better than the zero-point motion of the resonator. Increasing the coupling of the resonator to detector will eventually result in back-action driving of the motion, adding imprecision and enforcing this limit. We demonstrated that our system is capable of precisions approaching this limit, and identified the primary experimental factors preventing us from reaching it: noise added to the measurement by our amplifier, and excess dissipation appearing in our microwave resonator at high pump powers. Furthermore, by applying both red- and blue-detuned phase-coherent microwave pump signals, we demonstrated back-action evading (BAE) measurement sensitive to only a single quadrature of the motion. By avoiding the back-action driving in the measured quadrature, such a technique has the potential for precisions surpassing the limit of the zero-point motion. With this method, we achieved a measurement precision of ∼ 100 fm, or 4 times the quantum zero-point motion of the mechanical resonator. We found that the measured quadrature is insensitive to back-action driving by at least a factor of 82 relative to the unmeasured quadrature. We also identified a mechanical parametric amplification effect which arises during the BAE measurement. This effect sets limits on the BAE performance but also mechanically preamplifies the motion, resulting in a position resolution 1.3 times the zero-point motion. We discuss how to overcome the experimental limits set by amplifier noise, pump power and parametric amplification. These results serve to define the path forward for demonstrating truly quantum-limited measurement and non-classical states of motion in a nearly-macroscopic object.

•Jan 1, 2009•5 citations
Continuous quantum displacement measurements are fundamentally limited by a trade-off between readout imprecision and measurement back-action, constrained by the Heisenberg uncertainty principle. In the Laser Interferometric Gravitational-Wave Observatory (LIGO), these two quantum noise components dominate much of the observation band, making it an excellent testbed. We induce a sub-Hz-linewidth optomechanical mode by trapping the differential motion of the 40-kg mirrors in a band where radiation-pressure back-action dominates the motion. Engineering the quantum state entering the dark port creates correlations between imprecision and back-action that partially cancel their contributions, reducing observed motion near resonance by ~47%. A framework resolving the imprecision, back-action, and correlation terms identifies the origin of this suppression. These results demonstrate quantum back-action evasion and quantum reservoir engineering in a macroscopic optomechanical system.
Continuous displacement measurements combine quantum imprecision and radiation-pressure back-action; correlations can reduce their combined contribution. This paper investigates these effects in LIGO Livingston by placing the differential motion of four 40-kg mirrors, with effective mass ∼10\sim10∼10 kg, inside the detector’s quantum-noise-sensitive band.
Digital feedback creates a mechanical resonance near 151151151 Hz with quality factor ∼100\sim100∼100. With circulating power and trapping parameters fixed, displacement spectra are compared for ordinary vacuum, frequency-independent squeezing (FIS), and frequency-dependent squeezing (FDS). FIS reduces high-frequency imprecision but increases low-frequency back-action. FDS retains comparable high-frequency imprecision while reducing observed displacement-noise power near resonance by (47±5)%(47\pm5)\%(47±5)% relative to vacuum and (31±7)%(31\pm7)\%(31±7)% relative to FIS.
A multiport interferometer model, fitted jointly across configurations, attributes the suppression to negative imprecision–back-action correlations. The decomposition uses the power dependence SxxQN=A/P+BP+CS_{xx}^{\mathrm{QN}}=A/P+BP+CSxxQN​=A/P+BP+C to identify imprecision, back-action, and correlation contributions. Consistent inferred classical-noise residuals across configurations support this interpretation; the decomposition is model-derived rather than obtained from an experimental power scan.
The paper also interprets squeezed illumination as an engineered reservoir. Subtracting modeled imprecision and integrating the inferred motion gives equivalent occupations of 324±38324\pm38324±38 for vacuum, 423±30423\pm30423±30 for FIS, and 198±23198\pm23198±23 for FDS. These are inferred equivalent occupations, not demonstrations of nonclassical mechanical states. The stated limitations include feedback delays and stability requirements restricting the trap quality factor, and residual classical noise—primarily coating thermal noise—contributing approximately 125125125 phonons and limiting further reservoir-based state engineering.
Advanced LIGO is a gravitational-wave detector with extreme sensitivity, operating close to the quantum limits of optical measurement. The quantum noise in this system arises from vacuum fluctuations entering the interferometer readout port: phase-like fluctuations produce measurement imprecision, while amplitude-like fluctuations drive radiation-pressure back-action. In this review, we present an intuitive description in terms of complex fields and quadratures, and follow squeezed vacuum from its generation, through its interaction with the filter cavity and propagation through the interferometer, to the readout. We discuss how frequency-independent and frequency-dependent squeezing engineer quantum noise, and how correlations between optical quadratures map onto correlations between measurement imprecision and back-action. We conclude that LIGO is both a gravitational-wave observatory and a kilometre-scale platform for quantum measurement science.
In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.
Advances in precision optomechanical measurement underpin a wide range of technologies, from inertial sensors to the detection of gravitational waves and the exploration of fundamental physics. For such applications, the ultimate sensitivity is limited by quantum noise: shot noise, which stems from the stochastic arrival of photons, dominates at high frequencies, while Quantum Back-Action (QBA) noise—arising from the random radiation-pressure force exerted by the light field—prevails at low frequencies. The interplay between these two contributions defines the Standard Quantum Limit (SQL) of interferometry, a power-dependent trade-off that constrains further performance improvements. Although several sub-SQL techniques have been demonstrated, they typically enhance narrow-band sensitivity or require long filter cavities. Coherent Quantum Noise Cancellation (CQNC), first proposed by Tsang and Caves, offers a broadband solution by introducing an Effective Negative-Mass Oscillator (ENMO) that destructively interferes with the QBA noise across the entire spectrum except at the mechanical resonance of the opto-mechanically coupled system. A mathematically equivalent scheme for broadband QBA evasion has been demonstrated—for example, using atomic ensembles. The operation of this scheme is restricted to specific atomic transition wavelengths and is therefore unsuitable for many optomechanical platforms. This thesis reports the first all-optical, table-top realisation of an ENMO capable of Coherent Quantum Noise Cancellation in quantum optomechanical sensors. The scheme employs an optical analogue of the optomechanical interaction, generated through a combination of parametric down-conversion and beam-splitting processes, yielding a tunable, wavelength-flexible, and compact system. The achieved parameters satisfy the CQNC targets established in earlier theoretical work, and the current system predicts a broadband quantum-noise reduction of 3.6 dB (77% suppression of QBA noise(in dB)) at the frequency of maximum suppression. With further reduction of intracavity losses, the projected cancellation improves to 11.9 dB (81% suppression (in dB)). The experimental realisation features two polarisation-coupled optical resonators that host a two-mode squeezing interaction; the optical resonators possess distinct detunings and linewidths. The interdependent nature of the ENMO system motivated the development of an in-situ characterisation method, which is essential for integrating the ENMO with an optomechanical system in practical applications. Adequately addressing the system’s complexity required the development of five specialised experimental techniques for parameter tuning and comprehensive characterisation. Beyond quantum-noise cancellation, this system lends itself to application in quantum-information and quantum-communication tasks, including an on-demand, high-purity single-photon source and a quantum memory. Owing to the optical platform’s immunity to thermal decoherence, it can be operated at room temperature, and the parametric down-conversion process affords flexibility in wavelength selection. The results presented here advance the state of the art in broadband quantum noise reduction in a broad class of optomechanical devices, with immediate relevance for emerging quantum-technology applications.
Cavity Optomechanics, that is the study of the interaction between an optical cavity mode and a mechanical degree of freedom, has known impressive evolution over the past decade, to become a new field at the union of condensed matter physics and optics. One of the major goals of this discipline is to test and study quantum mechanics using macroscopic systems. Among the most fundamental problems the community aims to address is the question of the quantum limits in position measurement. Quantum mechanics predicts that any measurement comes along with a backaction, which perturbs the state of the measured system. Moreover, it is expected to be conjugated with the quantum noise of the measurement apparatus (called measurement noise) used to probe the system. The optimal sensitivity is reached whenever both the measurement and the backaction noise are identical, a situation which can be assimilated to the acceptance of Heisenberg's inequality for the measurement apparatus. In cavity optomechanics, the mode of an optical cavity is used as a measurement apparatus of the position of a mechanical resonator which is expected to be responsible for the backaction imprecision. However, this so-called radiation pressure quantum backaction has never been observed to date, while it remains a decisive step towards understanding quantum measurement processes. We describe in this manuscript the study of radiation pressure effects in cavity optomechanics. We introduce the optomechanical system we have developed, which consists in a cm-scale ultra high Q (~ 1 000 000) plano-convex mechanical resonator incorporated into a ultra-high finesse (~ 300 000) Fabry-Prot cavity. We present two important results we obtained with this system. First, we were able to report the first direct observation of radiation pressure in real-time, based on establishing pump-probe correlations. We were also able to demonstrate for the first time nonlinear backaction effects related to substantial improvement of position measurement sensitivity. We explain why demonstrating quantum backaction requires ultra-high stability of the optical mode. We present important changes made to the previous experimental setup, notably on the laser source, on the detection and the stabilization of the experiment. We then describe a new optomechanical detection technique providing an independent measurement of the cavity detuning. Finally, we present a proof-of-principle experiment allowing to extract quantum optomechanical correlations at room temperature.
Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.
The application of quantum mechanics to macroscopic motion suggests many counterintuitive phenomena. While the quantum nature of the motion of individual atoms and molecules has long been successfully studied, an equivalent demonstration of the motion of a near-macroscopic structure remains a challenge in experimental physics. A nanomechanical resonator is an excellent system for such a study. It typically contains > 10 10 atoms, and it may be modeled in terms of macroscopic parameters such as bulk density and elasticity. Yet it behaves like a simple harmonic oscillator, with mass low enough and resonant frequency high enough for its quantum zero-point motion and single energy quanta to be experimentally accessible. In pursuit of quantum phenomena in a mechanical oscillator, two important goals are to prepare the oscillator in its quantum ground state, and to measure its position with a precision limited by the Heisenberg uncertainty principle. In this work we have demonstrated techniques that advance towards both of these goals. Our system comprises a 30 micron × 170 nm, 2.2 pg, 5.57 MHz nanomechanical resonator capacitively coupled to a 5 GHz superconducting microwave resonator. The microwave resonator and nanomechanical resonator are fabricated together onto a single silicon chip and measured in a dilution refrigerator at temperatures below 150 mK. At these temperatures the coupling of the motion to the thermal environment is very small, resulting in a very high mechanical Q, approaching ∼ 10 6 . By driving with a microwave pump signal, we observed sidebands generated by the mechanical motion and used these to measure the thermal motion of the resonator. Applying a pump tone red-detuned from the microwave resonance, we used the microwave field to damp the mechanical resonator, extracting energy and "cooling" the motion in a manner similar to optical cooling of trapped atoms. Starting from a mode temperature of ∼ 150 mK, we reached ∼ 40 mK by this "backaction cooling" technique, corresponding to an occupation factor only ∼ 150 times above the ground state of motion. We also determined the precision of our device in measurement of position. Quantum mechanics dictates that, in a continuous position measurement, the precision may be no better than the zero-point motion of the resonator. Increasing the coupling of the resonator to detector will eventually result in back-action driving of the motion, adding imprecision and enforcing this limit. We demonstrated that our system is capable of precisions approaching this limit, and identified the primary experimental factors preventing us from reaching it: noise added to the measurement by our amplifier, and excess dissipation appearing in our microwave resonator at high pump powers. Furthermore, by applying both red- and blue-detuned phase-coherent microwave pump signals, we demonstrated back-action evading (BAE) measurement sensitive to only a single quadrature of the motion. By avoiding the back-action driving in the measured quadrature, such a technique has the potential for precisions surpassing the limit of the zero-point motion. With this method, we achieved a measurement precision of ∼ 100 fm, or 4 times the quantum zero-point motion of the mechanical resonator. We found that the measured quadrature is insensitive to back-action driving by at least a factor of 82 relative to the unmeasured quadrature. We also identified a mechanical parametric amplification effect which arises during the BAE measurement. This effect sets limits on the BAE performance but also mechanically preamplifies the motion, resulting in a position resolution 1.3 times the zero-point motion. We discuss how to overcome the experimental limits set by amplifier noise, pump power and parametric amplification. These results serve to define the path forward for demonstrating truly quantum-limited measurement and non-classical states of motion in a nearly-macroscopic object.