Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.04907

Microkelvin resolution thermometry at the nanometre scale

Jack W. Hart, Soham Pal, Julien R. E. Roth, Katie Ninham, Abbie H. Aleksandrova, Xander Peetroons, Soumen Mandal, Oliver A. Williams, Gavin W. Morley, Mete Atature, Helena S. Knowles

quant-phphysics.app-phphysics.ins-detSubmitted Sep 4, 2026• Announced Sep 7, 2026• 1 citation
arXivHTMLPDF

Abstract

Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 $μ$K, experimental sensitivities below 50 mK/$\surd \text{Hz}$ and a shot-noise limited sensitivity of 9.6 mK/$\surd \text{Hz}$. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.

Comments
8 pages, 3 figures

Related papers

Cross‐Correlated Quantum Thermometry Using Diamond Containing Dual‐Defect Centers

Madhav Gupta, Tongtong Zhang, Lambert Yeung +7 more

Abstract The contactless temperature measurement at micro/nanoscale is vital to a broad range of fields in modern science and technology. The nitrogen‐vacancy (NV) center, a kind of diamond defect with unique spin‐dependent photoluminescence, is recognized as one of the most promising nanothermometers. However, this quantum thermometry technique is prone to a number of possible perturbations, which will unavoidably degrade its actual temperature sensitivity. Here, for the first time, a cross‐validated optical thermometry method is developed using a bulk diamond sample containing both NV centers and silicon‐vacancy (SiV) centers, achieving a sensitivity of 22 and 86 mK (√Hz) −1 respectively. Particularly, the latter has been intrinsically immune to those influencing perturbations for the NV‐based quantum thermometry, hence serving as a real‐time cross‐validation system. As a proof‐of‐concept demonstration, a trustworthy temperature measurement is shown under the influence of varying magnetic fields, which is a common artefact present in practical systems. This multi‐modality approach allows synchronized cross‐validation of the measured temperature, which is required for micro/nanoscale quantum thermometry in complicated environments such as a living cell.

arXiv:2303.00073•Advanced Sensor Research•Sep 10, 2023•5 citations

Fluorescence thermometry enhanced by the quantum coherence of single spins in diamond

D.M. Toyli, Charles F. de las Casas, David J. Christle +2 more

We demonstrate fluorescence thermometry techniques with sensitivities approaching 10 mK · Hz(-1/2) based on the spin-dependent photoluminescence of nitrogen vacancy (NV) centers in diamond. These techniques use dynamical decoupling protocols to convert thermally induced shifts in the NV center's spin resonance frequencies into large changes in its fluorescence. By mitigating interactions with nearby nuclear spins and facilitating selective thermal measurements, these protocols enhance the spin coherence times accessible for thermometry by 45-fold, corresponding to a 7-fold improvement in the NV center's temperature sensitivity. Moreover, we demonstrate these techniques can be applied over a broad temperature range and in both finite and near-zero magnetic field environments. This versatility suggests that the quantum coherence of single spins could be practically leveraged for sensitive thermometry in a wide variety of biological and microscale systems.

arXiv:1303.6730•Proceedings of the National Academy of Sciences•May 6, 2013•415 citations

Laser-induced heating in a high-density ensemble of nitrogen-vacancy centers in diamond and its effects on quantum sensing

Dewen Duan, Vinaya K. Kavatamane, Sri Ranjini Arumugam +5 more

Among quantum sensors, the single nitrogen-vacancy (NV) defect in diamond has the highest sensitivity-to-size factor. For instance, a single-NV spin when used as a magnetometer could achieve sensitivities of the order of nT/Hz, while the dimensions of the sensor are merely atomic in size. The sensitivity is limited only by the photon shot noise. One method to boost the magnetometer sensitivity to pico-tesla scales is to use many NV defect centers as an ensemble sensor [Phys. Rev. X5, 041001 (2015)PRXHAE2160-330810.1103/PhysRevX.5.041001]. However, during the absorption-emission (fluorescence) optical cycles, the NV centers transfer a portion of the irradiation laser energy into phonons and heat the diamond matrix. This results in unintended fluorescence decrease, spin resonance lines shifts, and fluctuations. Hence, the advantages gained by packing a high density of NV centers are significantly reduced. Here we investigate the heat generation of ensemble NV centers in micrometer-sized diamond under 532 nm laser irradiation and its effects pertaining to sensing applications. These investigations help us to find strategies that mitigate the detrimental effects of heating and yet permits the use of ensemble NV defects for improved metrology applications.

Optics Letters•May 24, 2019•18 citations

Temporal filtered quantum sensing with the nitrogen-vacancy center in diamond

Florian Boehm, Yan Liu, Chengliang Yue +5 more

Nitrogen vacancy centers in diamond are among the leading solid state quantum platforms, offering exceptional spatial resolution and sensitivity for applications such as magnetic field sensing, thermometry, and bioimaging. However, in high background environments,such as those encountered in in vitro diagnostics, the performance of NV based sensors can be compromised by strong background fluorescence, particularly from substrates such as nitrocellulose. In this work, we analytically and experimentally investigate the use of pulsed laser excitation combined with time gating techniques to suppress background fluorescence and enhance the signal to noise ratio in NV based quantum sensing, with an emphasis on spin enhanced biosensing. Through experimental studies using mixed ensembles of silicon vacancy and NV centers in bulk diamond, as well as fluorescent nanodiamonds on NC substrates, we demonstrate significant improvements in NV spin resonance visibility, demonstrated by an increase of the SNR by up to 4x, and a resulting measurement time reduction by 16x. The presented technique and results here can help significantly increase the readout efficiency and speed in future applications of NV centers in high background environments, such as in IVD, where the NV centers are used as a fluorescent label for biomolecules.

quant-pharXiv:2511.02369•Nov 5, 2025

Engineering Nanodiamonds for Quantum Sensing: Material Constraints at the Nanoscale

Ashutosh Rathi, Keisuke Oshimi, Kento Sasaki +6 more

Optically addressable solid-state spin defects have emerged as powerful multimodal quantum sensors, with nitrogen-vacancy (NV) centers in bulk diamond providing benchmark quantum control and sensitivity under ambient conditions. Embedding such defects in nanodiamonds (NDs) extends these capabilities to mobile probes capable of accessing complex biological and nanoscale environments. Reduced dimensions, however, introduce constraints beyond volumetric spin impurities, notably enhanced lattice strain and surface-induced noise sources, which shorten NV spin relaxation times (T1 and T2) and destabilize the NV charge state, as well as resulting in pronounced particle-to-particle variability in NDs typically produced by top-down approaches. These effects complicate both sensing performance and the quantitative interpretation of multimodal signals in realistic environments. This article provides a structured perspective on the physical mechanisms by which material properties constrain NV behavior in NDs, together with mitigation strategies that shape the robust use of these mobile quantum sensors for biosensing and nanoscale science.

quant-pharXiv:2608.04489•Aug 6, 2026

High-sensitivity temperature sensing on an ensemble of nitrogen-vacancy centers in diamond

Wu Da-Jin, Zhonghao Li, Zhenrong Shi +3 more

Abstract We demonstrate a method for thermal detection that is the sensitivity 6.2 mK Hz −1 2 , which uses the frequency lock closed-loop scheme to track Zeeman-split resonance of nitrogen-vacancy (NV) centers in diamond. The NV diamond surface acts as a temperature measurement sensor to transfer the temperature variation as D ( T ) parameter change to lead to the movement of the energy levels to detect the temperature. By frequency modulation technology and closed-loop feedback locking technology, automatic temperature detection and step signal reading are realized, with a resolution of 7.6 mK. It is found that the closed-loop output is basically unchanged, while the open-loop output has an error signal proportional to the laser fluctuation. The closed-loop feedback technique can improve the stability and resolution of the system and provides a method for measuring the actual temperature detection. Such a demonstration marks a vital advance in transitioning the NV thermometer from a laboratory system to a functional device for detecting temperature fields in a practical environment.

Japanese Journal of Applied Physics•Jun 20, 2022•3 citations
Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 μμμK, experimental sensitivities below 50 mK/√Hz\surd \text{Hz}√Hz and a shot-noise limited sensitivity of 9.6 mK/√Hz\surd \text{Hz}√Hz. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.
Abstract The contactless temperature measurement at micro/nanoscale is vital to a broad range of fields in modern science and technology. The nitrogen‐vacancy (NV) center, a kind of diamond defect with unique spin‐dependent photoluminescence, is recognized as one of the most promising nanothermometers. However, this quantum thermometry technique is prone to a number of possible perturbations, which will unavoidably degrade its actual temperature sensitivity. Here, for the first time, a cross‐validated optical thermometry method is developed using a bulk diamond sample containing both NV centers and silicon‐vacancy (SiV) centers, achieving a sensitivity of 22 and 86 mK (√Hz) −1 respectively. Particularly, the latter has been intrinsically immune to those influencing perturbations for the NV‐based quantum thermometry, hence serving as a real‐time cross‐validation system. As a proof‐of‐concept demonstration, a trustworthy temperature measurement is shown under the influence of varying magnetic fields, which is a common artefact present in practical systems. This multi‐modality approach allows synchronized cross‐validation of the measured temperature, which is required for micro/nanoscale quantum thermometry in complicated environments such as a living cell.
We demonstrate fluorescence thermometry techniques with sensitivities approaching 10 mK · Hz(-1/2) based on the spin-dependent photoluminescence of nitrogen vacancy (NV) centers in diamond. These techniques use dynamical decoupling protocols to convert thermally induced shifts in the NV center's spin resonance frequencies into large changes in its fluorescence. By mitigating interactions with nearby nuclear spins and facilitating selective thermal measurements, these protocols enhance the spin coherence times accessible for thermometry by 45-fold, corresponding to a 7-fold improvement in the NV center's temperature sensitivity. Moreover, we demonstrate these techniques can be applied over a broad temperature range and in both finite and near-zero magnetic field environments. This versatility suggests that the quantum coherence of single spins could be practically leveraged for sensitive thermometry in a wide variety of biological and microscale systems.
Among quantum sensors, the single nitrogen-vacancy (NV) defect in diamond has the highest sensitivity-to-size factor. For instance, a single-NV spin when used as a magnetometer could achieve sensitivities of the order of nT/Hz, while the dimensions of the sensor are merely atomic in size. The sensitivity is limited only by the photon shot noise. One method to boost the magnetometer sensitivity to pico-tesla scales is to use many NV defect centers as an ensemble sensor [Phys. Rev. X5, 041001 (2015)PRXHAE2160-330810.1103/PhysRevX.5.041001]. However, during the absorption-emission (fluorescence) optical cycles, the NV centers transfer a portion of the irradiation laser energy into phonons and heat the diamond matrix. This results in unintended fluorescence decrease, spin resonance lines shifts, and fluctuations. Hence, the advantages gained by packing a high density of NV centers are significantly reduced. Here we investigate the heat generation of ensemble NV centers in micrometer-sized diamond under 532 nm laser irradiation and its effects pertaining to sensing applications. These investigations help us to find strategies that mitigate the detrimental effects of heating and yet permits the use of ensemble NV defects for improved metrology applications.
Nitrogen vacancy centers in diamond are among the leading solid state quantum platforms, offering exceptional spatial resolution and sensitivity for applications such as magnetic field sensing, thermometry, and bioimaging. However, in high background environments,such as those encountered in in vitro diagnostics, the performance of NV based sensors can be compromised by strong background fluorescence, particularly from substrates such as nitrocellulose. In this work, we analytically and experimentally investigate the use of pulsed laser excitation combined with time gating techniques to suppress background fluorescence and enhance the signal to noise ratio in NV based quantum sensing, with an emphasis on spin enhanced biosensing. Through experimental studies using mixed ensembles of silicon vacancy and NV centers in bulk diamond, as well as fluorescent nanodiamonds on NC substrates, we demonstrate significant improvements in NV spin resonance visibility, demonstrated by an increase of the SNR by up to 4x, and a resulting measurement time reduction by 16x. The presented technique and results here can help significantly increase the readout efficiency and speed in future applications of NV centers in high background environments, such as in IVD, where the NV centers are used as a fluorescent label for biomolecules.
Optically addressable solid-state spin defects have emerged as powerful multimodal quantum sensors, with nitrogen-vacancy (NV) centers in bulk diamond providing benchmark quantum control and sensitivity under ambient conditions. Embedding such defects in nanodiamonds (NDs) extends these capabilities to mobile probes capable of accessing complex biological and nanoscale environments. Reduced dimensions, however, introduce constraints beyond volumetric spin impurities, notably enhanced lattice strain and surface-induced noise sources, which shorten NV spin relaxation times (T1 and T2) and destabilize the NV charge state, as well as resulting in pronounced particle-to-particle variability in NDs typically produced by top-down approaches. These effects complicate both sensing performance and the quantitative interpretation of multimodal signals in realistic environments. This article provides a structured perspective on the physical mechanisms by which material properties constrain NV behavior in NDs, together with mitigation strategies that shape the robust use of these mobile quantum sensors for biosensing and nanoscale science.
Abstract We demonstrate a method for thermal detection that is the sensitivity 6.2 mK Hz −1 2 , which uses the frequency lock closed-loop scheme to track Zeeman-split resonance of nitrogen-vacancy (NV) centers in diamond. The NV diamond surface acts as a temperature measurement sensor to transfer the temperature variation as D ( T ) parameter change to lead to the movement of the energy levels to detect the temperature. By frequency modulation technology and closed-loop feedback locking technology, automatic temperature detection and step signal reading are realized, with a resolution of 7.6 mK. It is found that the closed-loop output is basically unchanged, while the open-loop output has an error signal proportional to the laser fluctuation. The closed-loop feedback technique can improve the stability and resolution of the system and provides a method for measuring the actual temperature detection. Such a demonstration marks a vital advance in transitioning the NV thermometer from a laboratory system to a functional device for detecting temperature fields in a practical environment.