Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.04363

Phase Independent Measurement of Weak Coherent Optical Signals

Lani Chastain, Priya Drashni, Mahadeva Chanda Durjoy, Hari P. Lamsal, Girish S. Agarwal, Tian Li

quant-phSubmitted Sep 3, 2026• Announced Sep 7, 2026• 0 citations
arXivHTMLPDF

Abstract

We develop a quantum sensing framework for the phase independent detection of weak coherent optical displacements based on SU(1,1) interferometry. Unlike conventional quantum measurement protocols that require prior knowledge of the signal phase and coherent homodyne detection, the proposed approach estimates the displacement magnitude independently of its phase. We show that, under ideal lossless conditions, a conventional SU(1,1) interferometer employing only total intensity detection saturates the quantum Cramer Rao bound for displacement magnitude estimation. We further derive the analytical expression of the quantum Cramer Rao bound and the sensitivity of the conventional SU(1,1) interferometer with total intensity detection and systematically investigate its performance in the presence of optical loss. The proposed phase-independent intensity detection scheme achieves comparable performance over experimentally relevant operating regimes while eliminating the need for local oscillators, phase locking, and quadrature tracking. These results establish SU(1,1) based intensity detection as a practical platform for phase independent quantum sensing.

Comments
8 pages, 7 figures

Related papers

Quantum optical metrology in the lossy SU(2) and SU(1,1) interferometers

Yang Gao

We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.

arXiv:1606.08966•Physical Review A•Aug 18, 2016•25 citations

Phase estimation of an SU(1,1) interferometer with superposition of even and odd coherent states

Abdelmajid El Maaroufi, Mouad Ait Maskour, Bouchra Maroufi +1 more

Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.

Physica Scripta•Feb 25, 2026•0 citations

Optimized phase sensing in a truncated SU(1,1) interferometer

Prasoon Gupta, Bonnie L. Schmittberger, Brian E. Anderson +2 more

Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.

arXiv:1802.04314•Optics Express•Jan 4, 2018•58 citations

Supersensitive phase estimation for hybrid interferometer using balanced homodyne detection

Tao Shao, Minyang Zhang, Chenlu Li +4 more

Abstract We have theoretically investigated the phase sensitivity of the hybrid interferometer with two coherent beams using the method of balance homodyne detection. The measurement device is a nonlinear–linear hybrid interferometer consisting of an optical parametric amplifier and a beam splitter. We prove that the phase sensitivity can beat the shot noise limit in the optimal conditions. Furthermore, we derive the quantum Cramér–Rao bound of the hybrid interferometer. The effects of transmission loss and detection loss on the measurement accuracy are discussed. The detection accuracy of this scheme is compared with that of the conventional SU (1,1) interferometer. Our results show that this scheme outperforms the conventional SU (1,1) interferometer scheme at high parametric strength. This scheme can be implemented with existing experimental techniques and will have important applications in quantum precision measurements.

Journal of Physics B Atomic Molecular and Optical Physics•Oct 24, 2023•4 citations

SU(1,1) interferometry with parity measurement

Shuai Wang, Jiandong Zhang

We present a new operator method in the Heisenberg representation to obtain the signal of parity measurement within a lossless SU(1,1) interferometer. Based on this method, it is convenient to derive the parity signal directly in terms of input states, including general Gaussian and non-Gaussian states. As applications, we revisit the signal of parity measurement within an SU(1,1) interferometer when a coherent or thermal state and a squeezed vacuum state are considered as input states. In addition, we obtain the parity signal of an arbitrary single-mode state when it passes through an SU(1,1) interferometer, which is also a new result. Then, we analytically prove that parity measurement can saturate the quantum Cramér–Rao bound when the estimated phase approaches zero. Therefore, the operator method proposed in this work may bring convenience to the study of quantum metrology, particularly the phase estimation based on an SU(1,1) interferometer.

arXiv:2104.09718•Journal of the Optical Society of America B•Aug 2, 2021•12 citations

Temporal SU(1,1) Interferometer: Approaching the Quantum Limit in Dynamic Phase Estimation

Zepeng Liu, Weiping Zhang, Chun-Hua Yuan

We theoretically derive the quantum Fisher information for a temporal SU(1,1) interferometer driven by coherent light, and demonstrate that balanced homodyne detection enables the system to approach the quantum Cramér-Rao bound with high efficiency, making it well suited for high-precision measurement of rapidly time-varying phase signals.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Aug 1, 2026•0 citations
We develop a quantum sensing framework for the phase independent detection of weak coherent optical displacements based on SU(1,1) interferometry. Unlike conventional quantum measurement protocols that require prior knowledge of the signal phase and coherent homodyne detection, the proposed approach estimates the displacement magnitude independently of its phase. We show that, under ideal lossless conditions, a conventional SU(1,1) interferometer employing only total intensity detection saturates the quantum Cramer Rao bound for displacement magnitude estimation. We further derive the analytical expression of the quantum Cramer Rao bound and the sensitivity of the conventional SU(1,1) interferometer with total intensity detection and systematically investigate its performance in the presence of optical loss. The proposed phase-independent intensity detection scheme achieves comparable performance over experimentally relevant operating regimes while eliminating the need for local oscillators, phase locking, and quadrature tracking. These results establish SU(1,1) based intensity detection as a practical platform for phase independent quantum sensing.
We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.
Abstract The SU(1,1) interferometer, a nonlinear analog of the traditional Mach–Zehnder interferometer, has emerged as a powerful tool for achieving phase sensitivity beyond the standard quantum limit. In this work, we propose the use of a superposition of even and odd coherent states as input state to enhance the phase sensitivity of an SU(1,1) interferometer. These non-classical states exhibit unique properties such as squeezing, entanglement, and quantum interference, which can be harnessed to improve metrological precision. Phase sensitivity is analyzed using single-intensity detection and homodyne detection schemes under both ideal and photon loss cases, which demonstrates significant improvements over classical and squeezed-vacuum inputs. In addition, we evaluate the quantum Cramér-Rao lower bound by employing the quantum Fisher information formalism, showing that it surpasses the standard quantum limit and approaches the Heisenberg limit under optimal conditions. Our results highlight the potential of the even and odd coherent states superposition in quantum metrology and provide a pathway for achieving ultra-precise phase measurements in SU(1,1) interferometers for applications in optical sensing, and quantum information processing.
Homodyne detection is often used for interferometers based on nonlinear optical gain media. For the configuration of a seeded, "truncated SU(1,1)" interferometer Anderson, et al. [ Phys. Rev. A95, 063843 (2017)] showed how to optimize the homodyne detection scheme and demonstrated theoretically that it can saturate the quantum Cramer-Rao bound for phase estimation. In this work we extend those results by taking into account loss in the truncated SU(1,1) interferometer and determining the optimized homodyne detection scheme for phase measurement. Further, we build a truncated SU(1,1) interferometer and experimentally demonstrate that this optimized scheme achieves a reduction in noise level, corresponding to an enhanced potential phase sensitivity, compared to a typical homodyne detection scheme for a two-mode squeezed state. In doing so, we also demonstrate an improvement in the degree to which we can beat the standard quantum limit with this device.
Abstract We have theoretically investigated the phase sensitivity of the hybrid interferometer with two coherent beams using the method of balance homodyne detection. The measurement device is a nonlinear–linear hybrid interferometer consisting of an optical parametric amplifier and a beam splitter. We prove that the phase sensitivity can beat the shot noise limit in the optimal conditions. Furthermore, we derive the quantum Cramér–Rao bound of the hybrid interferometer. The effects of transmission loss and detection loss on the measurement accuracy are discussed. The detection accuracy of this scheme is compared with that of the conventional SU (1,1) interferometer. Our results show that this scheme outperforms the conventional SU (1,1) interferometer scheme at high parametric strength. This scheme can be implemented with existing experimental techniques and will have important applications in quantum precision measurements.
We present a new operator method in the Heisenberg representation to obtain the signal of parity measurement within a lossless SU(1,1) interferometer. Based on this method, it is convenient to derive the parity signal directly in terms of input states, including general Gaussian and non-Gaussian states. As applications, we revisit the signal of parity measurement within an SU(1,1) interferometer when a coherent or thermal state and a squeezed vacuum state are considered as input states. In addition, we obtain the parity signal of an arbitrary single-mode state when it passes through an SU(1,1) interferometer, which is also a new result. Then, we analytically prove that parity measurement can saturate the quantum Cramér–Rao bound when the estimated phase approaches zero. Therefore, the operator method proposed in this work may bring convenience to the study of quantum metrology, particularly the phase estimation based on an SU(1,1) interferometer.