Atom interferometers (AIFs) are highly precise inertial sensors and are considered promising instruments for the detection of gravitational waves (GWs) and certain dark matter (DM) candidates in the mid-frequency band. While GW detection with AIFs was initially proposed for space-based experiments with baselines spanning thousands of kilometers, recent developments suggest that terrestrial setups with baselines of at least 100 meters may also be capable of detecting GWs. In this work, we analytically derive the GW phase response formula of a ground detector, find an additional term compared to the existing literature and check it our findings numerically. Based on this treatment, we analyze the optimal geometric parameters for earth-bound AIF experiments. Subsequently, we numerically simulate GW detection schemes for these optimized interferometers using an open-source Python algorithm. Numerical simulations of these schemes have are not available to the community, yet crucial for the accurate modeling of noise and non-trivial gravitational backgrounds.
Atom interferometers (AIFs) are highly precise inertial sensors and are considered promising instruments for the detection of gravitational waves (GWs) and certain dark matter (DM) candidates in the mid-frequency band. While GW detection with AIFs was initially proposed for space-based experiments with baselines spanning thousands of kilometers, recent developments suggest that terrestrial setups with baselines of at least 100 meters may also be capable of detecting GWs. In this work, we analytically derive the GW phase response formula of a ground detector, find an additional term compared to the existing literature and check it our findings numerically. Based on this treatment, we analyze the optimal geometric parameters for earth-bound AIF experiments. Subsequently, we numerically simulate GW detection schemes for these optimized interferometers using an open-source Python algorithm. Numerical simulations of these schemes have are not available to the community, yet crucial for the accurate modeling of noise and non-trivial gravitational backgrounds.
Atom interferometry is a quantum sensor technology that uses ultra-cold atoms placed in entangled quantum states to detect minute changes in local fields arising from gravitational waves and ultra-light dark matter. Their extreme sensitivity to accelerations has been demonstrated for measurements of Newton’s gravitation constant, tests of the Equivalence Principle, and measurement of local gravity gradients. The search for ultra-light dark matter and measurements of gravitational waves requires interferometer baselines greater than approximately 100 m. In understanding the fundamental systematics and backgrounds of these detectors, we have discovered that atmospheric and seismic effects, even though physically decoupled from the atoms which are in vacuum and free-fall, are still detectable by the quantum phase of the atoms. From a different perspective these “noise” sources are also interesting signals that we may be able to understand better with these sensor platforms leading to cross-disciplinary studies in Earth sciences.
Abstract Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for very-long-baseline atom interferometerssuch as AION 1 , MAGIS 2 , AICE 3 and AEDGE 4 that aim to detect at frequencies at which ground-based 5 and space-borne 6 laser interferometers lose sensitivity. Very-long-baseline atom interferometers look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. The experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87 Sr. Thus, we obtain a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the standard quantum limit 7 with no excess noise beyond atom shot noise. The differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, which emulates the conditions expected in a very-long-baseline atom interferometer. We also demonstrate the recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomized conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying very-long-baseline atom interferometers and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter 8,9 .
Abstract MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.
Abstract Currently planned and constructed terrestrial detectors for gravitational waves and dark matter based on differential light-pulse atom interferometry are designed around three primary strategies to enhance their sensitivity: (i) Resonant-mode enhancement using multiple diamonds, (ii) large-momentum-transfer (LMT) techniques to increase arm separation within the interferometer, and (iii) very-long baseline schemes that increase the distance between the two interferometers. Both resonant-mode enhancement and LMT techniques result in a greater number of light pulses, making high pulse fidelity during atom-light interactions imperative. At the same time, increasing the number of diamonds in vertical configurations leads to taller atomic fountains, which consequently reduces the available distance between interferometers. As a result, the number of diamonds, LMT pulses, and the fountain height are interdependent parameters that must be carefully balanced. In this work, we present optimal configurations for multi-diamond geometries in resonant mode, explicitly accounting for the spatial extent of a single interferometer, considering constraints imposed by the baseline dimensions and atomic losses due to imperfect pulses. For this optimization, we numerically scan the relevant parameters such as initial position and momentum of the atomic cloud, transferred momenta, and number of loops. For each parameter set, we verify whether the imposed conditions are met and evaluate the resulting sensitivities to identify optimal configurations. We provide practical analytical relations to estimate the optimal number of pulses that should be applied. Many proposals beyond demonstrator experiments require pulse numbers that demand efficiencies not yet demonstrated with state-of-the-art momentum transfer techniques. As a result, the observed sensitivity falls short of expectations—an effect caused by both arm separation and atom loss per pulse—highlighting the urgent need for research aimed at improving pulse fidelities.
Single-photon transitions are one of the key technologies for designing and operating very-long-baseline atom interferometers tailored for terrestrial gravitational-wave and dark-matter detection. Since such setups aim at the detection of relativistic and beyond-Standard-Model physics, the analysis of interferometric phases as well as of atomic diffraction must be performed to this precision and including these effects. In contrast, most treatments focused on idealized diffraction so far. Here, we study single-photon transitions, both magnetically induced and direct ones, in gravity and Standard-Model extensions modeling dark matter as well as Einstein-equivalence-principle violations. We take into account relativistic effects like the coupling of internal to center-of-mass degrees of freedom, induced by the mass defect, as well as the gravitational redshift of the diffracting light pulse. To this end, we also include chirping of the light pulse required by terrestrial setups, as well as its associated modified momentum transfer for single-photon transitions.
Abstract Light pulse atom interferometers (AIFs) are exquisite quantum probes of spatial inhomogeneity and gravitational curvature. Moreover, detailed measurement and calibration are necessary prerequisites for very-long-baseline atom interferometry (VLBAI). Here we provide a theoretical analysis of the phase resulting in a complex gravitational environment and introduce a novel interferometer geometry which singles out the phase shift proportional to the curvature of the gravitational potential. The scale factor depends only on well controlled quantities, namely the photon wave number, the interferometer time and the atomic recoil, which allows the curvature to be accurately inferred from a measured phase. As a case study, we numerically simulate such a gradiometric interferometer in the context of the Hannover VLBAI facility and prove the robustness of the phase shift in gravitational fields with complex spatial dependence. We define an estimator of the gravitational curvature for non-trivial gravitational fields and calculate the trade-off between signal strength and estimation accuracy with regard to spatial resolution. As a perspective, we discuss the case of a time-dependent gravitational field and corresponding measurement strategies.