Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2607.29099

A low-temperature ultra-high-vacuum scanning probe microscope with in situ electronic transport capabilities: from macro to nano in 10 minutes

Diego Exposito, Oscar Custance, Ivan Brihuega

cond-mat.mes-hallcond-mat.mtrl-scicond-mat.supr-conphysics.ins-detquant-phSubmitted Jul 31, 2026• Announced Aug 3, 2026
arXivHTMLPDF

Abstract

We have developed a low temperature (LT), ultra-high-vacuum (UHV) system that combines two complementary techniques, scanning probe microscopy (SPM) and electrical transport measurements, within a single platform. By providing simultaneous access to the atomic-scale surface landscape and the macroscopic device response of the same sample, the setup enables direct correlations between local structural/spectroscopic signatures and global electronic transport behavior in two-dimensional (2D) devices. The system allows experiments where atomic-scale modifications or controlled manipulations are performed while continuously monitoring their impact on device-scale performance. The setup consists of two interconnected UHV chambers: a dedicated preparation chamber and a separate measurement chamber that houses a liquid-helium cryostat and the SPM/transport stage. Base pressure is 1x10^-11 Torr. A key feature is direct optical access to the sample, enabling rapid and reliable tip positioning with an accuracy of 5 microns x 5 microns within 10 minutes. The SPM, operated using custom-built electronics, can track the exact same sample region across a temperature range from 2.9 K to 400 K, with mechanical stability below 1 pm. System performance is demonstrated on graphene devices, and bulk Pb is used to determine energy resolution. Using superconducting tips, scanning tunneling spectroscopy measures the superconducting gap with an energy resolution of 30 microV. Transport measurements track the temperature dependence of both resistivity and critical current across the superconducting transition of an in-situ prepared Pb nanowire.

Comments
19 pages, 10 figures

Related papers

Towards Ultra-High Vacuum Operation in a TEM for Quantum-Computer-Enhanced Electron Microscopy

Martino Zanetti, Dominik Hornof, Michael Stanislaus Seifner +2 more

Quantum electron microscopy is an emerging research field at the intersection of electron microscopy, quantum optics, and nanophotonics. Free electrons can serve as powerful quantum probes, on par with photons in their ability to carry and transfer quantum information, generate entanglement within and with a specimen, and reveal previously inaccessible details on nanoscale quantum phenomena [1]. However, quantum experiments are generally highly sensitive to decoherence arising from interactions with residual gas particles, making ultra-high vacuum (UHV) conditions sometimes essential. UHV environments are also required in transmission electron microscopes (TEMs) for the investigation of contamination-sensitive materials [2, 3]. In our project, we aim to combine a trapped-ion quantum computer with a TEM to realise Quantum-Computer-Enhanced Electron Microscopy (QCEM) (www.qcem.info). In this scheme, coherent interactions between free electrons and a trapped ion require vacuum conditions beyond the standard TEM operation [4]. Although UHV-TEM systems have previously been realised [2,3, 5-7], achieving base pressures in the 10⁻⁹ mbar range or better typically involves significant financial investment, long implementation times, and close collaboration with manufacturers. We present a cost-effective, minimally invasive modification to the vacuum system of a JEOL JEM-2100F to reduce the base pressure at the sample position to below 5 × 10⁻⁹ mbar. Our approach is to integrate two additional 50 L/s NEG-ion pumps mounted on flanges near the sample region, with no structural modifications to the microscope. The NEG pumps are integrated into the microscope workflow through controlled activation and regeneration cycles compatible with standard TEM operation. This work represents a practical step toward enabling the realisation of QCEM, and the concept enables a relatively rapid implementation at a moderate cost, which can, in principle, be adapted to any TEM that provides suitable flange access to the sample chamber.

•Apr 20, 2026•0 citations

A novel cryogenic scanning laser microscope tested on Josephson tunnel junctions

Jason D. Holm, J. Mygind

A novel cryogenic scanning laser microscope with a spatial resolution of less than 5 μm has been designed for on-chip in situ investigations of the working properties of normal and superconducting circuits and devices. The instrument relies on the detection of the electrical response of the circuit to a very localized heating induced by irradiation with 675 nm wavelength light from a semiconductor laser. The hot spot is moved by a specially designed piezoelectric scanner sweeping the tip of a single-mode optical fiber a few μm above the circuit. Depending on the scanner design the scanning area can be as large as 50×500 μm2 at 4.2 K. The microscope can be operated in the temperature range 2–300 K using a standard temperature controller. The central microscope body is mounted inside the vacuum can of a dip-stick-type cryoprobe. A damped spring system is used to reduce interference from extraneous mechanical vibrations. The microscope is integrated in a personal-computer-based data acquisition and control setup.

Review of Scientific Instruments•Sep 1, 1995•3 citations

A dry cryogenic platform with picometre stability for nanoscale and quantum technologies

William G. Roth, Andreas Thurn, Alexander M. Stramma +4 more

Mechanically ultrastable environments within maintenance-free dry cryostats are needed for high-precision surface probe microscopy experiments, as well as next-generation quantum technologies. The most demanding applications require picometre-scale precision combined with multi-axis and millimetre-scale scanning range, while offering access to optical, microwave, and radiofrequency control and a vector magnetic field. We demonstrate a versatile platform for such systems based on passive and active vibration control for a commercial dry cryostat. Using a tunable optical microcavity as a sensor, we report vibration levels of 4.2 pm root mean square at 2.3 K over one hour without postselection. We further demonstrate drift-free long-term operation with stability below 8.6 pm RMS over 12 hours. Our system enables continuous and automated operation for next-generation high-throughput applications without the need for liquid helium infrastructure. Requiring only standard machining facilities and commercially available hardware, the design can be readily adapted for cryogenic optical, electrical and magnetic high-precision measurements across quantum science, surface science, and nanotechnology.

arXiv:2610.23407•Oct 16, 2026•0 citations

WannierSTM: Efficient superconducting scanning-probe spectroscopy from maximally localized Wannier functions

Oscar Moreno Segura, Dorye L. Esteras, Andrei Shumilin +3 more

We present a Python-based program that combines maximally localized Wannier functions-based first-principles electronic structure with the nonequilibrium Green's function formalism to enable efficient simulations of scanning tunneling microscopy (STM). The workflow builds upon standard density functional theory packages to construct compact transport Hamiltonians that preserve the properties of realistic materials. Superconductivity is incorporated via an effective pairing potential within the Nambu-spinor formalism, while coupling to the STM tip and substrate electrodes is treated using the wide-band limit approximation. Within this formulation, transport quantities such as current-voltage characteristics and differential conductance are evaluated in a closed analytical form. This avoids explicit numerical energy integrations and enables rapid spectroscopic calculations over broad parameter spaces. The framework provides a unified and computationally efficient approach for modeling superconducting hybrid nanostructures with spin-orbit coupling, magnetic textures, and spin polarization. Representative applications in spin chains, two-dimensional and molecular magnets on a superconductor demonstrate its robust capabilities for both simple model systems and realistic ab initio molecular structures relevant to modern STM experiments.

cond-mat.mes-hallCross-listedarXiv:2610.17943•Oct 14, 2026

A cold atom apparatus for the microscopy of thin membranes

Amruta Gadge

Ultracold atomic gases can be utilised as extremely sensitive probes of their surrounding environment. In particular, samples of ultracold atoms confined using chip-based microtraps are an ideal tool for mapping electric and magnetic field landscapes. Over the course of this thesis, a new experiment capable of performing surface microscopy using magnetically trapped clouds of cold rubidium-87 atoms has been built. The focus of the work is on the design and construction of the experimental system, which must incorporate many different aspects for manipulating thermal atomic gases, with a view to positioning them at sub-micron distances from special surfaces. This reduced atom-surface separation is necessary for implementing a high resolution, high sensitivity magnetic field sensor with cold atoms. Although current microfabrication techniques easily enable trapping at distances on the order of micrometres, several distance-dependent surface effects - such as the Casimir-Polder force, Johnson-Nyquist noise, and stray potentials - eventually impede magnetic trapping at the sub-micron level. These surface effects can greatly modify the confining potentials, which reduces the trap depth and consequently leads to an additional loss rate of atoms from the trap. We have explored the possibility of using special surfaces such as nano-membranes of silicon nitride and graphene, which have reduced atom- surface interactions, to enable trapping distances at the sub-micron level. A multilayer printed circuit board chip has been designed to form an initial magnetic trap and then transport the cloud of atoms to a desired location over the samples. This chip, along with various samples, is mounted on a custom-made electrical feedthrough designed to make connections to all conductor that are inside the vacuum chamber. The initial cloud of cold atoms can then be prepared in the central region of the chip and delivered to the location of the samples on either side. The experimental system is able to routinely capture over 10^8 rubidium-87 atoms at a temperature of 80 micro-Kelvin in a magneto-optical trap using a novel scheme of five laser beams. A method is demonstrated for enhancing the atom number in the magneto-optical traps by a factor of two by using laser beams with two slightly different frequencies. Atoms from the magneto-optical trap are then transferred to a purely magnetic trap formed by the wires on the printed circuit board chip. Time-dependent currents in the chip wires then create a dynamic potential, which is shown to successfully transport the atomic sample over a distance of 12 millimetre with minimal atom loss. This thesis describes the development of the apparatus in detail, along with careful characterisation of the cold cloud at various stages of the experimental sequence. Initial results on the long distance atom transport are presented. Finally, the experimental results of the two frequency magneto-optical trap for atom number improvement are discussed.

•Jul 19, 2018•0 citations

From Structure to Coherence: Comprehensive Electron Microscopy Analysis of Superconducting Quantum Devices

Thang Pham, Matthew Cheng, Dominic P. Goronzy +4 more

The development of quantum computers, capable of surpassing classical computing in solving specific complex problems, hinges on breakthroughs in materials science, precision device fabrication, and the optimization of quantum architectures [1]. Among the leading candidates for quantum computation, superconducting qubits, particularly those based on transmon designs, have shown promising advances with coherence times reaching hundreds of microseconds [2]. However, to fully unlock the potential of scalable quantum computing, further enhancements in coherence are necessary. The intricate structure-coherence relationship within these devices, especially at critical interfaces such as metal-air, metal-dielectric, and metal-substrate in Josephson junctions (JJs), poses a significant challenge due to the potential for two-level-system loss channels. Here, we detail our pioneering efforts to understand these structure-coherence relationships utilizing advanced electron microscopy techniques. Focusing on the Al-AlOx and Al-Si substrate interfaces in Josephson Junctions, we employ a combination of low-loss and core-loss electron energy loss spectroscopy (EELS) and four-dimensional scanning transmission electron microscopy (4D-STEM) conducted at room and ultra-low temperatures (sub-6 K). This approach allows for an unprecedented examination of the chemical composition, bonding environments, and nanoscale structures of key surfaces and interfaces critical to the quantum coherence. Figure 1 presents a typical superconducting architecture at the chip level; each superconducting qubit consists of a Josephson Junction in parallel with an ultra-low-loss capacitor to create a resonant structure in the 3-6GHz range. JJs are highlighted in the area boxed in Fig. 1A and can be observed in detail in Fig. 1B. Lamella cross-sections (as shown in Fig. 1C) were prepared using a dual-beam focused ion beam (FIB) FEI-SEM Helios Nanolab. The lift-off was performed using 30 kV Ga+ ions, and the final cleaning step was carried out at 2 kV to remove surface damage on the area of interest, resulting in a final sample thickness of 50-100 nm. Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) data were collected on a probe-corrected JEOL ARM200 S/TEM operating at 200 kV. The convergent angle for ADF-STEM imaging was 25 mrad. Electron energy loss spectra (EELS) were acquired at 200 kV using a Gatan GIF Quantum on a K2 pixelated detector. Data processing (background subtraction, plural scattering removal, and signal mapping) was conducted using Gatan GMS software. Four-dimensional STEM (4D-STEM) data were collected by a K3 and STELA cameras. The convergent angles were 0.5-1.5 mrad, and the camera length was 6-10 cm. The step size was 5-10 Å. Merging microscopic insights with electrical data and theoretical frameworks, we aim to reveal how atomic-scale irregularities affect coherence times. Our results highlight key decoherence mechanisms in superconducting qubits and suggest specific improvements for qubit design and manufacturing. By linking electron microscopy findings to device performance, we outline strategies to reduce decoherence, essential for achieving reliable quantum computing. This work bridges materials science and quantum engineering, driving efforts in making scalable quantum computers forward [3]. A) Microscopic view of a superconducting transmon qubit, highlighting its symmetric design with central island and capacitor pads. B) SEM image of a JJ displaying their Al top and bottom contacts. C) STEM image of a JJ showing its key components and interfaces: Al top and bottom contact, AlOx tunnel barrier, Si substrate and Al-Si interface. A) EELS chemical maps of two interfaces, Al/Al and Al/Si using K-edges of oxygen, aluminum and silicon of a Josephson junction. It is possible to detect a formation of oxides at both interfaces. Plots showing Al and Si K-edge at 1560 eV and 1839 eV, respectively, and the ELNES are shown on the right side (Scale bar in A – 20 nm). B) Analysis of the disordered Al phases at the interfaces utilizing ePDF.

Microscopy and Microanalysis•Jul 1, 2024•0 citations
We have developed a low temperature (LT), ultra-high-vacuum (UHV) system that combines two complementary techniques, scanning probe microscopy (SPM) and electrical transport measurements, within a single platform. By providing simultaneous access to the atomic-scale surface landscape and the macroscopic device response of the same sample, the setup enables direct correlations between local structural/spectroscopic signatures and global electronic transport behavior in two-dimensional (2D) devices. The system allows experiments where atomic-scale modifications or controlled manipulations are performed while continuously monitoring their impact on device-scale performance. The setup consists of two interconnected UHV chambers: a dedicated preparation chamber and a separate measurement chamber that houses a liquid-helium cryostat and the SPM/transport stage. Base pressure is 1x10^-11 Torr. A key feature is direct optical access to the sample, enabling rapid and reliable tip positioning with an accuracy of 5 microns x 5 microns within 10 minutes. The SPM, operated using custom-built electronics, can track the exact same sample region across a temperature range from 2.9 K to 400 K, with mechanical stability below 1 pm. System performance is demonstrated on graphene devices, and bulk Pb is used to determine energy resolution. Using superconducting tips, scanning tunneling spectroscopy measures the superconducting gap with an energy resolution of 30 microV. Transport measurements track the temperature dependence of both resistivity and critical current across the superconducting transition of an in-situ prepared Pb nanowire.
Quantum electron microscopy is an emerging research field at the intersection of electron microscopy, quantum optics, and nanophotonics. Free electrons can serve as powerful quantum probes, on par with photons in their ability to carry and transfer quantum information, generate entanglement within and with a specimen, and reveal previously inaccessible details on nanoscale quantum phenomena [1]. However, quantum experiments are generally highly sensitive to decoherence arising from interactions with residual gas particles, making ultra-high vacuum (UHV) conditions sometimes essential. UHV environments are also required in transmission electron microscopes (TEMs) for the investigation of contamination-sensitive materials [2, 3]. In our project, we aim to combine a trapped-ion quantum computer with a TEM to realise Quantum-Computer-Enhanced Electron Microscopy (QCEM) (www.qcem.info). In this scheme, coherent interactions between free electrons and a trapped ion require vacuum conditions beyond the standard TEM operation [4]. Although UHV-TEM systems have previously been realised [2,3, 5-7], achieving base pressures in the 10⁻⁹ mbar range or better typically involves significant financial investment, long implementation times, and close collaboration with manufacturers. We present a cost-effective, minimally invasive modification to the vacuum system of a JEOL JEM-2100F to reduce the base pressure at the sample position to below 5 × 10⁻⁹ mbar. Our approach is to integrate two additional 50 L/s NEG-ion pumps mounted on flanges near the sample region, with no structural modifications to the microscope. The NEG pumps are integrated into the microscope workflow through controlled activation and regeneration cycles compatible with standard TEM operation. This work represents a practical step toward enabling the realisation of QCEM, and the concept enables a relatively rapid implementation at a moderate cost, which can, in principle, be adapted to any TEM that provides suitable flange access to the sample chamber.
A novel cryogenic scanning laser microscope with a spatial resolution of less than 5 μm has been designed for on-chip in situ investigations of the working properties of normal and superconducting circuits and devices. The instrument relies on the detection of the electrical response of the circuit to a very localized heating induced by irradiation with 675 nm wavelength light from a semiconductor laser. The hot spot is moved by a specially designed piezoelectric scanner sweeping the tip of a single-mode optical fiber a few μm above the circuit. Depending on the scanner design the scanning area can be as large as 50×500 μm2 at 4.2 K. The microscope can be operated in the temperature range 2–300 K using a standard temperature controller. The central microscope body is mounted inside the vacuum can of a dip-stick-type cryoprobe. A damped spring system is used to reduce interference from extraneous mechanical vibrations. The microscope is integrated in a personal-computer-based data acquisition and control setup.
Mechanically ultrastable environments within maintenance-free dry cryostats are needed for high-precision surface probe microscopy experiments, as well as next-generation quantum technologies. The most demanding applications require picometre-scale precision combined with multi-axis and millimetre-scale scanning range, while offering access to optical, microwave, and radiofrequency control and a vector magnetic field. We demonstrate a versatile platform for such systems based on passive and active vibration control for a commercial dry cryostat. Using a tunable optical microcavity as a sensor, we report vibration levels of 4.2 pm root mean square at 2.3 K over one hour without postselection. We further demonstrate drift-free long-term operation with stability below 8.6 pm RMS over 12 hours. Our system enables continuous and automated operation for next-generation high-throughput applications without the need for liquid helium infrastructure. Requiring only standard machining facilities and commercially available hardware, the design can be readily adapted for cryogenic optical, electrical and magnetic high-precision measurements across quantum science, surface science, and nanotechnology.
We present a Python-based program that combines maximally localized Wannier functions-based first-principles electronic structure with the nonequilibrium Green's function formalism to enable efficient simulations of scanning tunneling microscopy (STM). The workflow builds upon standard density functional theory packages to construct compact transport Hamiltonians that preserve the properties of realistic materials. Superconductivity is incorporated via an effective pairing potential within the Nambu-spinor formalism, while coupling to the STM tip and substrate electrodes is treated using the wide-band limit approximation. Within this formulation, transport quantities such as current-voltage characteristics and differential conductance are evaluated in a closed analytical form. This avoids explicit numerical energy integrations and enables rapid spectroscopic calculations over broad parameter spaces. The framework provides a unified and computationally efficient approach for modeling superconducting hybrid nanostructures with spin-orbit coupling, magnetic textures, and spin polarization. Representative applications in spin chains, two-dimensional and molecular magnets on a superconductor demonstrate its robust capabilities for both simple model systems and realistic ab initio molecular structures relevant to modern STM experiments.
Ultracold atomic gases can be utilised as extremely sensitive probes of their surrounding environment. In particular, samples of ultracold atoms confined using chip-based microtraps are an ideal tool for mapping electric and magnetic field landscapes. Over the course of this thesis, a new experiment capable of performing surface microscopy using magnetically trapped clouds of cold rubidium-87 atoms has been built. The focus of the work is on the design and construction of the experimental system, which must incorporate many different aspects for manipulating thermal atomic gases, with a view to positioning them at sub-micron distances from special surfaces. This reduced atom-surface separation is necessary for implementing a high resolution, high sensitivity magnetic field sensor with cold atoms. Although current microfabrication techniques easily enable trapping at distances on the order of micrometres, several distance-dependent surface effects - such as the Casimir-Polder force, Johnson-Nyquist noise, and stray potentials - eventually impede magnetic trapping at the sub-micron level. These surface effects can greatly modify the confining potentials, which reduces the trap depth and consequently leads to an additional loss rate of atoms from the trap. We have explored the possibility of using special surfaces such as nano-membranes of silicon nitride and graphene, which have reduced atom- surface interactions, to enable trapping distances at the sub-micron level. A multilayer printed circuit board chip has been designed to form an initial magnetic trap and then transport the cloud of atoms to a desired location over the samples. This chip, along with various samples, is mounted on a custom-made electrical feedthrough designed to make connections to all conductor that are inside the vacuum chamber. The initial cloud of cold atoms can then be prepared in the central region of the chip and delivered to the location of the samples on either side. The experimental system is able to routinely capture over 10^8 rubidium-87 atoms at a temperature of 80 micro-Kelvin in a magneto-optical trap using a novel scheme of five laser beams. A method is demonstrated for enhancing the atom number in the magneto-optical traps by a factor of two by using laser beams with two slightly different frequencies. Atoms from the magneto-optical trap are then transferred to a purely magnetic trap formed by the wires on the printed circuit board chip. Time-dependent currents in the chip wires then create a dynamic potential, which is shown to successfully transport the atomic sample over a distance of 12 millimetre with minimal atom loss. This thesis describes the development of the apparatus in detail, along with careful characterisation of the cold cloud at various stages of the experimental sequence. Initial results on the long distance atom transport are presented. Finally, the experimental results of the two frequency magneto-optical trap for atom number improvement are discussed.
The development of quantum computers, capable of surpassing classical computing in solving specific complex problems, hinges on breakthroughs in materials science, precision device fabrication, and the optimization of quantum architectures [1]. Among the leading candidates for quantum computation, superconducting qubits, particularly those based on transmon designs, have shown promising advances with coherence times reaching hundreds of microseconds [2]. However, to fully unlock the potential of scalable quantum computing, further enhancements in coherence are necessary. The intricate structure-coherence relationship within these devices, especially at critical interfaces such as metal-air, metal-dielectric, and metal-substrate in Josephson junctions (JJs), poses a significant challenge due to the potential for two-level-system loss channels. Here, we detail our pioneering efforts to understand these structure-coherence relationships utilizing advanced electron microscopy techniques. Focusing on the Al-AlOx and Al-Si substrate interfaces in Josephson Junctions, we employ a combination of low-loss and core-loss electron energy loss spectroscopy (EELS) and four-dimensional scanning transmission electron microscopy (4D-STEM) conducted at room and ultra-low temperatures (sub-6 K). This approach allows for an unprecedented examination of the chemical composition, bonding environments, and nanoscale structures of key surfaces and interfaces critical to the quantum coherence. Figure 1 presents a typical superconducting architecture at the chip level; each superconducting qubit consists of a Josephson Junction in parallel with an ultra-low-loss capacitor to create a resonant structure in the 3-6GHz range. JJs are highlighted in the area boxed in Fig. 1A and can be observed in detail in Fig. 1B. Lamella cross-sections (as shown in Fig. 1C) were prepared using a dual-beam focused ion beam (FIB) FEI-SEM Helios Nanolab. The lift-off was performed using 30 kV Ga+ ions, and the final cleaning step was carried out at 2 kV to remove surface damage on the area of interest, resulting in a final sample thickness of 50-100 nm. Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) data were collected on a probe-corrected JEOL ARM200 S/TEM operating at 200 kV. The convergent angle for ADF-STEM imaging was 25 mrad. Electron energy loss spectra (EELS) were acquired at 200 kV using a Gatan GIF Quantum on a K2 pixelated detector. Data processing (background subtraction, plural scattering removal, and signal mapping) was conducted using Gatan GMS software. Four-dimensional STEM (4D-STEM) data were collected by a K3 and STELA cameras. The convergent angles were 0.5-1.5 mrad, and the camera length was 6-10 cm. The step size was 5-10 Å. Merging microscopic insights with electrical data and theoretical frameworks, we aim to reveal how atomic-scale irregularities affect coherence times. Our results highlight key decoherence mechanisms in superconducting qubits and suggest specific improvements for qubit design and manufacturing. By linking electron microscopy findings to device performance, we outline strategies to reduce decoherence, essential for achieving reliable quantum computing. This work bridges materials science and quantum engineering, driving efforts in making scalable quantum computers forward [3]. A) Microscopic view of a superconducting transmon qubit, highlighting its symmetric design with central island and capacitor pads. B) SEM image of a JJ displaying their Al top and bottom contacts. C) STEM image of a JJ showing its key components and interfaces: Al top and bottom contact, AlOx tunnel barrier, Si substrate and Al-Si interface. A) EELS chemical maps of two interfaces, Al/Al and Al/Si using K-edges of oxygen, aluminum and silicon of a Josephson junction. It is possible to detect a formation of oxides at both interfaces. Plots showing Al and Si K-edge at 1560 eV and 1839 eV, respectively, and the ELNES are shown on the right side (Scale bar in A – 20 nm). B) Analysis of the disordered Al phases at the interfaces utilizing ePDF.