Biophysical EPR Using Superconducting Resonators

Austin R. Gamble Jarvi, Hamid R. Mohebbi, Ishit Raval, Omari Culzac, Jack Erickson, Sameh Hegazy, Don Carkner, Andrew Wiles, David G. Cory, Troy W. Borneman

quant-phSubmitted Jun 22, 2026• Announced Jun 24, 2026
arXivHTMLPDF

Abstract

We present innovations that enable the use of superconducting resonators for high sensitivity, high bandwidth pulsed electron paramagnetic resonance (EPR) measurements on biologically relevant samples with enhanced stability and throughput. A custom-built X-band pulsed EPR spectrometer with AWG and digital IF capability generated by an FPGA was used to control a novel patterned thin film planar superconducting microstrip resonator capable of generating Rabi fields sufficient to achieve 6 ns pi/2 Gaussian pulses using a 100 W solid-state HPA. The system allows automated sequential calibration, measurement, and analysis of five 3.5 uL samples contained in a sample cartridge. Performance was validated through measurements of double electron-electron resonance (DEER) distances in a variety of spin-labeled protein samples with biologically relevant concentrations, including measurements below 10 uM. The results enable broadening the scope of applications for both superconducting resonators and the use of EPR in biotechnology.

Comments
15 pages, 6 figures

Related papers

Superconducting coplanar waveguide resonators for low temperature pulsed electron spin resonance spectroscopy

H. Malissa, David Schuster, Alexei M. Tyryshkin +2 more

We discuss the design and implementation of thin film superconducting coplanar waveguide micro-resonators for pulsed electron spin resonance experiments. The performance of the resonators with P doped Si epilayer samples is compared to waveguide resonators under equivalent conditions. The high achievable filling factor even for small sized samples and the relatively high Q-factor result in a sensitivity of 4.5 × 10(8) spins per shot, which is superior to that of conventional waveguide resonators, in particular to spins close to the sample surface. The peak microwave power is on the order of a few milliwatts, which is compatible with measurements at ultra-low temperatures. We also discuss the effect of the nonuniform microwave magnetic field on the Hahn echo power dependence.

arXiv:1202.6305•Review of Scientific Instruments•Feb 1, 2013•87 citations

High-Resolution Electron Paramagnetic Resonance

Colin J. Stephen, Anton Tcholakov, Maik Icker +7 more

Electron paramagnetic resonance (EPR) is a valuable tool for physics, chemistry, biology and medicine, providing complementary spectroscopic information to NMR. It has long been known that EPR at high magnetic fields offers greater spectral resolution, but limitations in the THz instrumentation have prevented the full realization of these opportunities. Here we describe an EPR spectrometer at the high magnetic field of 14 T using 396 GHz excitation, which adapts techniques from liquid-state NMR to obtain sharp EPR resonances with a width of 210 ppb (full-width half-maximum). We use this to measure resonance positions, and hence g-factors, with a precision that reaches $\pm$16 ppb. Our use of in-situ liquid-state NMR of our solvent within the same sample improves the accuracy of these measurements: it allows us to reference our EPR measurement back to dilute gas 3He NMR for which quantum calculations are accurate. We measure the g-factor of N@C60 in deuterated toluene as g = 2.002 099 09 (3), where the 3 in brackets means that the uncertainty on the last digit is $\pm$3.

physics.ins-detCross-listedarXiv:2601.14321•Jan 21, 2026

Electron paramagnetic resonance spectroscopy using a single artificial atom

Hiraku Toida, Yuichiro Matsuzaki, Kosuke Kakuyanagi +4 more

Abstract Electron paramagnetic resonance (EPR) spectroscopy is an important technology in physics, chemistry, materials science, and biology. Sensitive detection with a small sample volume is a key objective in these areas, because it is crucial, for example, for the readout of a highly packed spin based quantum memory or the detection of transition metals in biomaterials. Here, we demonstrate a novel EPR spectrometer using a single artificial atom as a sensitive detector of spin magnetization. The artificial atom, a superconducting flux qubit, provides advantages in terms of its strong coupling with magnetic fields. We estimate a sensitivity of ~400 spins·Hz−1/2 with a magnetic sensing volume around 10−14λ3 (50 femtoliters), where λ is the wavelength of the irradiated microwave. Our artificial atom works as a highly sensitive EPR spectrometer with micron-scale area with future opportunity for measuring single spins on the nanometer scale.

arXiv:1711.10148•Communications Physics•Mar 29, 2019•34 citations

In-situ amplification of spin echoes within a kinetic inductance parametric amplifier

Wyatt Vine, Mykhailo Savytskyi, Daniel Parker +6 more

The use of superconducting micro-resonators in combination with quantum-limited Josephson parametric amplifiers has in recent years lead to more than four orders of magnitude improvement in the sensitivity of pulsed Electron Spin Resonance (ESR) measurements. So far, the microwave resonators and amplifiers have been designed as separate components, largely due to the incompatibility of Josephson junction-based devices with even moderate magnetic fields. This has led to complex spectrometers that operate under strict environments, creating technical barriers for the widespread adoption of the technique. Here we circumvent this issue by inductively coupling an ensemble of spins directly to a weakly nonlinear microwave resonator, which is engineered from a magnetic field-resilient thin superconducting film. We perform pulsed ESR measurements with a $1$~pL effective mode volume and amplify the resulting spin signal using the same device, ultimately achieving a sensitivity of $2.8 \times 10^3$ spins in a single-shot Hahn echo measurement at a temperature of 400 mK. We demonstrate the combined functionalities at fields as large as 254~mT, highlighting the technique's potential for application under more conventional ESR operating conditions.

arXiv:2211.11333•Nov 21, 2022•2 citations

On-Chip Cavity Studies of Spin Systems and Nonlinear Superconducting Phenomena for Quantum Computing Applications

In this dissertation, the use of on-chip superconducting (SC) resonators as a probe of spin-photon interactions as well as other superconducting phenomena will be presented. In particular, coherent Rabi oscillations are demonstrated for a spin s=1/2 ensemble in an ESR (Electron Spin Resonance) cavity as well as coherent multiphoton excitations. Applying techniques from the classical ESR measurements to an on-chip resonator is effectively shrinking the cavity volume and increasing vacuum field density. This in turn can greatly increase the sensitivity creating the possibility of probing the quantum to classical transition for spin-photon interactions. Additionally, an on-chip cavity provides the possibility of on-chip ESR measurements to be performed in a dilution refrigerator. Furthermore, progress has been made toward on-chip ESR type measurements. A highly sensitive heterodyne measurement setup has been developed, providing the capability of detecting signals as small as -125~dBm. Under the right conditions this setup may be able to detect single photons. To perform an on-chip ESR measurement, precise placement of the spin system at an anti-node of the magnetic field is required. For this, a technique for spin ensemble placement with micron scale precision is developed. Finally, performing ESR measurements requires the application of a (sometimes large) static field. Even a very small static field and can easily create vortices in a superconducting thin film when applied normal to the film plane. A precise alignment procedure is developed allowing for the operation of on-chip SC resonators to operate with an in-plane field up to 1~Tesla. This led to the first successful field-dependent observation of the nonlinear Meissner effect.

•Jan 1, 2010•0 citations

On Design and Testing of a Spectrometer Based on An FPGA Development Board for use with Optimal Control Theory and High-Q Resonators

Steven Casagrande

Recent developments in quantum information processing have presented new and interesting ways to perform advanced algorithms and improve signal to noise ratios. Examples of these include optimal control theory pulse generation algorithms and the usage of high Q-factor resonators. However, these developments are blocked by current spectrometer designs. This thesis details the design and testing of a new spectrometer with sufficient accuracy, bandwidth, and control to implement these advances. The proposed solution is to use an FPGA-based development board together with custom computer software. This gives access to high-speed analogue inputs and outputs, as well as digital output pins. The spectrometer is then used in two X-band electron spin resonance experiments, showing how the advantages of the system allow for superior results to that possible with the previous equipment. In addition, the setup is used in a Nitrogen Vacancy (NV) system where a rabi experiment is performed.

•Feb 24, 2014•5 citations
We present innovations that enable the use of superconducting resonators for high sensitivity, high bandwidth pulsed electron paramagnetic resonance (EPR) measurements on biologically relevant samples with enhanced stability and throughput. A custom-built X-band pulsed EPR spectrometer with AWG and digital IF capability generated by an FPGA was used to control a novel patterned thin film planar superconducting microstrip resonator capable of generating Rabi fields sufficient to achieve 6 ns pi/2 Gaussian pulses using a 100 W solid-state HPA. The system allows automated sequential calibration, measurement, and analysis of five 3.5 uL samples contained in a sample cartridge. Performance was validated through measurements of double electron-electron resonance (DEER) distances in a variety of spin-labeled protein samples with biologically relevant concentrations, including measurements below 10 uM. The results enable broadening the scope of applications for both superconducting resonators and the use of EPR in biotechnology.
We discuss the design and implementation of thin film superconducting coplanar waveguide micro-resonators for pulsed electron spin resonance experiments. The performance of the resonators with P doped Si epilayer samples is compared to waveguide resonators under equivalent conditions. The high achievable filling factor even for small sized samples and the relatively high Q-factor result in a sensitivity of 4.5 × 10(8) spins per shot, which is superior to that of conventional waveguide resonators, in particular to spins close to the sample surface. The peak microwave power is on the order of a few milliwatts, which is compatible with measurements at ultra-low temperatures. We also discuss the effect of the nonuniform microwave magnetic field on the Hahn echo power dependence.
Electron paramagnetic resonance (EPR) is a valuable tool for physics, chemistry, biology and medicine, providing complementary spectroscopic information to NMR. It has long been known that EPR at high magnetic fields offers greater spectral resolution, but limitations in the THz instrumentation have prevented the full realization of these opportunities. Here we describe an EPR spectrometer at the high magnetic field of 14 T using 396 GHz excitation, which adapts techniques from liquid-state NMR to obtain sharp EPR resonances with a width of 210 ppb (full-width half-maximum). We use this to measure resonance positions, and hence g-factors, with a precision that reaches $\pm$16 ppb. Our use of in-situ liquid-state NMR of our solvent within the same sample improves the accuracy of these measurements: it allows us to reference our EPR measurement back to dilute gas 3He NMR for which quantum calculations are accurate. We measure the g-factor of N@C60 in deuterated toluene as g = 2.002 099 09 (3), where the 3 in brackets means that the uncertainty on the last digit is $\pm$3.
Abstract Electron paramagnetic resonance (EPR) spectroscopy is an important technology in physics, chemistry, materials science, and biology. Sensitive detection with a small sample volume is a key objective in these areas, because it is crucial, for example, for the readout of a highly packed spin based quantum memory or the detection of transition metals in biomaterials. Here, we demonstrate a novel EPR spectrometer using a single artificial atom as a sensitive detector of spin magnetization. The artificial atom, a superconducting flux qubit, provides advantages in terms of its strong coupling with magnetic fields. We estimate a sensitivity of ~400 spins·Hz−1/2 with a magnetic sensing volume around 10−14λ3 (50 femtoliters), where λ is the wavelength of the irradiated microwave. Our artificial atom works as a highly sensitive EPR spectrometer with micron-scale area with future opportunity for measuring single spins on the nanometer scale.
The use of superconducting micro-resonators in combination with quantum-limited Josephson parametric amplifiers has in recent years lead to more than four orders of magnitude improvement in the sensitivity of pulsed Electron Spin Resonance (ESR) measurements. So far, the microwave resonators and amplifiers have been designed as separate components, largely due to the incompatibility of Josephson junction-based devices with even moderate magnetic fields. This has led to complex spectrometers that operate under strict environments, creating technical barriers for the widespread adoption of the technique. Here we circumvent this issue by inductively coupling an ensemble of spins directly to a weakly nonlinear microwave resonator, which is engineered from a magnetic field-resilient thin superconducting film. We perform pulsed ESR measurements with a 111~pL effective mode volume and amplify the resulting spin signal using the same device, ultimately achieving a sensitivity of 2.8×1032.8 \times 10^32.8×103 spins in a single-shot Hahn echo measurement at a temperature of 400 mK. We demonstrate the combined functionalities at fields as large as 254~mT, highlighting the technique's potential for application under more conventional ESR operating conditions.
In this dissertation, the use of on-chip superconducting (SC) resonators as a probe of spin-photon interactions as well as other superconducting phenomena will be presented. In particular, coherent Rabi oscillations are demonstrated for a spin s=1/2 ensemble in an ESR (Electron Spin Resonance) cavity as well as coherent multiphoton excitations. Applying techniques from the classical ESR measurements to an on-chip resonator is effectively shrinking the cavity volume and increasing vacuum field density. This in turn can greatly increase the sensitivity creating the possibility of probing the quantum to classical transition for spin-photon interactions. Additionally, an on-chip cavity provides the possibility of on-chip ESR measurements to be performed in a dilution refrigerator. Furthermore, progress has been made toward on-chip ESR type measurements. A highly sensitive heterodyne measurement setup has been developed, providing the capability of detecting signals as small as -125~dBm. Under the right conditions this setup may be able to detect single photons. To perform an on-chip ESR measurement, precise placement of the spin system at an anti-node of the magnetic field is required. For this, a technique for spin ensemble placement with micron scale precision is developed. Finally, performing ESR measurements requires the application of a (sometimes large) static field. Even a very small static field and can easily create vortices in a superconducting thin film when applied normal to the film plane. A precise alignment procedure is developed allowing for the operation of on-chip SC resonators to operate with an in-plane field up to 1~Tesla. This led to the first successful field-dependent observation of the nonlinear Meissner effect.
Recent developments in quantum information processing have presented new and interesting ways to perform advanced algorithms and improve signal to noise ratios. Examples of these include optimal control theory pulse generation algorithms and the usage of high Q-factor resonators. However, these developments are blocked by current spectrometer designs. This thesis details the design and testing of a new spectrometer with sufficient accuracy, bandwidth, and control to implement these advances. The proposed solution is to use an FPGA-based development board together with custom computer software. This gives access to high-speed analogue inputs and outputs, as well as digital output pins. The spectrometer is then used in two X-band electron spin resonance experiments, showing how the advantages of the system allow for superior results to that possible with the previous equipment. In addition, the setup is used in a Nitrogen Vacancy (NV) system where a rabi experiment is performed.