Calibration of electric fields in low-frequency off-resonant Rydberg receivers

Baran Kayim, Michael A. Viray, David La Mantia, Daniel Richardson, James B. Dee, Ryan S. Westafer, Brian C. Sawyer, Robert Wyllie

Published Mar 11, 2026• 4 citations
arXivHTMLPDF

Abstract

We present results on Rydberg atom-based electric field sensing in the range of 1 kHz - 300 MHz, using a three-photon Rydberg excitation scheme and a transverse electromagnetic (TEM) line waveguide to apply low-frequency rf fields to the cell. Measurements of low-frequency screening in quartz and sapphire vapor cells show excellent agreement with a phenomenological model of the effective vapor cell material properties based on an electrical 2-port measurement of the TEM line. We achieve a best noise-equivalent field of 106(4) $\mathrm{\frac{μV}{m \sqrt{Hz}}}$ at 300 MHz and characterize noise-equivalent fields in the ultra-low to very-low frequency (ULF-VLF) band.

DOI
10.48550/arxiv.2603.10898

Related papers

High sensitivity measurement of ULF, VLF, and LF fields with a Rydberg-atom sensor

Mingwei Lei, Meng Shi

Fields with frequencies below megahertz are challenging for Rydberg-atom-based measurements, due to the low-frequency electric field screening effect caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this paper, we investigate electric field measurements in the ultralow frequency (ULF), very low frequency (VLF), and low frequency (LF) bands in a Cs vapor cell with built-in parallel electrodes. With optimization of the applied DC field, we achieve high-sensitive detection of the electric field at frequencies of 1 kHz, 10 kHz, and 100 kHz based on the Rydberg-atom sensor, with the minimum electric field strength down to 18.0 μV/cm, 6.9 μV/cm, and 3.0 μV/cm, respectively. The corresponding sensitivity is 5.7 μV/cm/Hz 1/2 , 2.2 μV/cm/Hz 1/2 , and 0.95 μV/cm/Hz 1/2 for the ULF, VLF, and LF fields, which is better than a 1-cm dipole antenna. Besides, the linear dynamic range of the Rydberg-atom sensor is over 50 dB. This work presents the potential to enable more applications that utilize atomic sensing technology in the ULF, VLF, and LF fields.

arXiv:2405.04761•Optics Letters•Sep 12, 2024•19 citations

Profiling a Rydberg-Atom Electric Field Sensor for Off-Resonant Detection of Sub-100 MHz RF Signals

Michael A. Viray, Abby Halasi-Kun, Baran Kayim +3 more

We present a Rydberg-Atom electric field sensor optimized to detect signals at sub-100 MHz carrier frequencies. The sensing setup employs a sapphire vapor cell that allows for detection of signals below 100 MHz-typical vapor cells made of glass or quartz demonstrate strong screening of radio frequency (RF) signals in this frequency regime. Applied signals are detected by observing AC Stark shifts in the atomic vapor energy levels. As a test case for the commercial utility of this receiver, we perform our tests at several carrier frequencies in the Industrial, Scientific, and Medical (ISM) band. At each carrier frequency, we report sensitivity, minimum detectable field, and detectable electric-field dynamic range. We also present a routine for optimizing off-resonant signal detection by tuning experimental parameters such as Rydberg coupler laser detuning and RF local oscillator strength. This Python-based optimization routine, which can be used at any off-resonant carrier frequency, is shared on GitHub for others to use in their own investigations.

arXiv:2606.10151•Sensors•Sep 17, 2026•0 citations

Electrometry of extremely-low frequencies from kHz to sub-Hz with a Rydberg-atom sensor

Aveek Chandra, Narongrit Paensin, Rainer Dumke

Rydberg-atom electric field sensing has shown great potential from near-DC to THz with state-of-the-art measurement metrics realized in sensitivity, phase extraction, multi-band receptivity, etc. While Rydberg-atom sensors have shown exceptional performance in the GHz regime, low-frequency operation has remained challenging because of electric-field-screening in conventional vapor cells, which suppresses externally applied fields. We overcome this limitation by combining auxiliary modulation and lock-in detection with a paraffin-coated vapor cell, and demonstrate an electrode-free, wideband method for sensing frequencies, ranging from 0.5 Hz to 10 kHz. Our work extends Rydberg-atom sensor range to VLF, ULF, SLF, ELF and sub-ELF frequency bands. In our method, high state-of-the-art sensitivities have been achieved - 819 $μ$V/cm/$\sqrt{\text{Hz}}$ for 1 Hz, 33 $μ$V/cm/$\sqrt{\text{Hz}}$ for 10 Hz, 10 $μ$V/cm/$\sqrt{\text{Hz}}$ for 100 Hz and 2 $μ$V/cm/$\sqrt{\text{Hz}}$ for 1 kHz.

quant-pharXiv:2603.13827•EPJ Quantum Technology•Mar 17, 2026•5 citations

Kilohertz-range electric field calibration in an alkali vapor cell using time-averaged Stark shifts

M. J. Lim, Marc Cervantes, Cameron Brady +2 more

We present a model-independent experimental method for calibrating the amplitude of a low-frequency electric field in an alkali vapor cell. Three-photon excitation to a Rydberg state in atomic rubidium produces an electromagnetically induced transparency (EIT) signal that is sensitive to low-frequency fields originating outside the cell. We superpose the measured shape of the EIT resonance in the presence of an electric field with the expected line shape, obtained by numerically time-averaging the effect of the DC-Stark shift. The value of the fractional field amplitude transmission, caused by Faraday screening by the metallic rubidium layer on the cell interior, is a direct result of this comparison. A transmission spectrum is obtained by making measurements between 0 and 100 kHz, which demonstrates high-pass filtering behavior described by two cutoff frequencies. Independently, finite-element simulation provides supporting evidence of the accuracy of the measurement, which is responsive to the nonuniform alkali distribution on the vapor cell wall. In combination with recent advances in the sensitivity of low-frequency electrometry, this may improve absolute, free-space measurements of weak, low-frequency electric fields that are of interest in basic and applied research.

Applied Physics Letters•Jul 31, 2023•12 citations

Low-noise low-frequency electric-field measurement using Rydberg-atom-mediated sum-frequency mixing

Yao Liu, Jun He, Nan Su +4 more

Low-frequency (LF) electric-field measurements with Rydberg atoms are limited by alkali-induced cell-surface screening and excess laser-intensity noise. Here, we address these limitations using a Cs vapor cell with built-in parallel electrodes, active laser-power stabilization, and a home-built balanced detector to suppress 10 Hz-kHz intensity noise. A 15 kHz local-oscillator field is introduced to up-convert Hz-scale signals to the lower-noise kHz band through Rydberg atom-mediated sum-frequency mixing (SFM), improving the optical readout signal-to-noise ratio. The system achieves a minimum detectable electric field of 190 nV/cm within 0.5 Hz-1.006 kHz, a linear dynamic range exceeding 67 dB, and a spectral resolution of 18 mHz.

Optics Letters•Sep 15, 2026•0 citations

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Yuan‐Yu Jau, Tony Carter

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. We report a very slow electric-field-screening phenomenon with a time scale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of $11\phantom{\rule{0.2em}{0ex}}{\mathrm{mm}}^{3}$ and delivers a spectral noise floor of around $0.34\phantom{\rule{0.2em}{0ex}}\mathrm{mV}/\mathrm{m}\phantom{\rule{0.1em}{0ex}}\sqrt{\mathrm{Hz}}$ and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-based atomic electrometry that was seldom studied before, which may enable more applications that use atomic electric-field-sensing technology.

arXiv:2002.04145•Physical Review Applied•May 14, 2020•149 citations
We present results on Rydberg atom-based electric field sensing in the range of 1 kHz - 300 MHz, using a three-photon Rydberg excitation scheme and a transverse electromagnetic (TEM) line waveguide to apply low-frequency rf fields to the cell. Measurements of low-frequency screening in quartz and sapphire vapor cells show excellent agreement with a phenomenological model of the effective vapor cell material properties based on an electrical 2-port measurement of the TEM line. We achieve a best noise-equivalent field of 106(4) μVmHz\mathrm{\frac{μV}{m \sqrt{Hz}}}mHz​μV​ at 300 MHz and characterize noise-equivalent fields in the ultra-low to very-low frequency (ULF-VLF) band.
Fields with frequencies below megahertz are challenging for Rydberg-atom-based measurements, due to the low-frequency electric field screening effect caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this paper, we investigate electric field measurements in the ultralow frequency (ULF), very low frequency (VLF), and low frequency (LF) bands in a Cs vapor cell with built-in parallel electrodes. With optimization of the applied DC field, we achieve high-sensitive detection of the electric field at frequencies of 1 kHz, 10 kHz, and 100 kHz based on the Rydberg-atom sensor, with the minimum electric field strength down to 18.0 μV/cm, 6.9 μV/cm, and 3.0 μV/cm, respectively. The corresponding sensitivity is 5.7 μV/cm/Hz 1/2 , 2.2 μV/cm/Hz 1/2 , and 0.95 μV/cm/Hz 1/2 for the ULF, VLF, and LF fields, which is better than a 1-cm dipole antenna. Besides, the linear dynamic range of the Rydberg-atom sensor is over 50 dB. This work presents the potential to enable more applications that utilize atomic sensing technology in the ULF, VLF, and LF fields.
We present a Rydberg-Atom electric field sensor optimized to detect signals at sub-100 MHz carrier frequencies. The sensing setup employs a sapphire vapor cell that allows for detection of signals below 100 MHz-typical vapor cells made of glass or quartz demonstrate strong screening of radio frequency (RF) signals in this frequency regime. Applied signals are detected by observing AC Stark shifts in the atomic vapor energy levels. As a test case for the commercial utility of this receiver, we perform our tests at several carrier frequencies in the Industrial, Scientific, and Medical (ISM) band. At each carrier frequency, we report sensitivity, minimum detectable field, and detectable electric-field dynamic range. We also present a routine for optimizing off-resonant signal detection by tuning experimental parameters such as Rydberg coupler laser detuning and RF local oscillator strength. This Python-based optimization routine, which can be used at any off-resonant carrier frequency, is shared on GitHub for others to use in their own investigations.
Rydberg-atom electric field sensing has shown great potential from near-DC to THz with state-of-the-art measurement metrics realized in sensitivity, phase extraction, multi-band receptivity, etc. While Rydberg-atom sensors have shown exceptional performance in the GHz regime, low-frequency operation has remained challenging because of electric-field-screening in conventional vapor cells, which suppresses externally applied fields. We overcome this limitation by combining auxiliary modulation and lock-in detection with a paraffin-coated vapor cell, and demonstrate an electrode-free, wideband method for sensing frequencies, ranging from 0.5 Hz to 10 kHz. Our work extends Rydberg-atom sensor range to VLF, ULF, SLF, ELF and sub-ELF frequency bands. In our method, high state-of-the-art sensitivities have been achieved - 819 μμμV/cm/Hz\sqrt{\text{Hz}}Hz​ for 1 Hz, 33 μμμV/cm/Hz\sqrt{\text{Hz}}Hz​ for 10 Hz, 10 μμμV/cm/Hz\sqrt{\text{Hz}}Hz​ for 100 Hz and 2 μμμV/cm/Hz\sqrt{\text{Hz}}Hz​ for 1 kHz.
We present a model-independent experimental method for calibrating the amplitude of a low-frequency electric field in an alkali vapor cell. Three-photon excitation to a Rydberg state in atomic rubidium produces an electromagnetically induced transparency (EIT) signal that is sensitive to low-frequency fields originating outside the cell. We superpose the measured shape of the EIT resonance in the presence of an electric field with the expected line shape, obtained by numerically time-averaging the effect of the DC-Stark shift. The value of the fractional field amplitude transmission, caused by Faraday screening by the metallic rubidium layer on the cell interior, is a direct result of this comparison. A transmission spectrum is obtained by making measurements between 0 and 100 kHz, which demonstrates high-pass filtering behavior described by two cutoff frequencies. Independently, finite-element simulation provides supporting evidence of the accuracy of the measurement, which is responsive to the nonuniform alkali distribution on the vapor cell wall. In combination with recent advances in the sensitivity of low-frequency electrometry, this may improve absolute, free-space measurements of weak, low-frequency electric fields that are of interest in basic and applied research.
Low-frequency (LF) electric-field measurements with Rydberg atoms are limited by alkali-induced cell-surface screening and excess laser-intensity noise. Here, we address these limitations using a Cs vapor cell with built-in parallel electrodes, active laser-power stabilization, and a home-built balanced detector to suppress 10 Hz-kHz intensity noise. A 15 kHz local-oscillator field is introduced to up-convert Hz-scale signals to the lower-noise kHz band through Rydberg atom-mediated sum-frequency mixing (SFM), improving the optical readout signal-to-noise ratio. The system achieves a minimum detectable electric field of 190 nV/cm within 0.5 Hz-1.006 kHz, a linear dynamic range exceeding 67 dB, and a spectral resolution of 18 mHz.
Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. We report a very slow electric-field-screening phenomenon with a time scale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11mm311\phantom{\rule{0.2em}{0ex}}{\mathrm{mm}}^{3}11mm3 and delivers a spectral noise floor of around 0.34mV/mHz0.34\phantom{\rule{0.2em}{0ex}}\mathrm{mV}/\mathrm{m}\phantom{\rule{0.1em}{0ex}}\sqrt{\mathrm{Hz}}0.34mV/mHz​ and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-based atomic electrometry that was seldom studied before, which may enable more applications that use atomic electric-field-sensing technology.