Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2511.04578 · New Journal of Physics

Homodyne detection for pulse-by-pulse squeezing measurements

Tiphaine Kouadou, Elie Gozlan, Loïc Garcia, David Polizzi, David Fainsin, Iris Paparelle, R. L. Rincón Celis, Bastien Oriot, Anthony Abi Aad, Peter Namdar, Ganaël Roland, Nicolas Treps, Bérengère Argence, Valentina Parigi

quant-phSubmitted Nov 6, 2025• Announced Nov 7, 2025• 4 citations
arXivHTMLPDF

Abstract

Homodyne detection is a phase-sensitive measurement technique, essential for the characterization of continuous-variable (CV)-encoded quantum states of light. It is a key component to the implementation of CV quantum-information protocols and benefits from operating, by design, at room temperature. However, performing high-speed quantum information processing remains a major challenge, as conventional homodyne detectors often fail to sustain pulsed operation at high repetition rates due to electronic limitations. We present wideband homodyne detectors operating at near-infrared (NIR) and telecom wavelengths, with optimized performance at repetition rates up to 150 MHz. We demonstrate their performance by resolving the pulse-by-pulse structure of squeezed states of light at telecom wavelengths while preserving their spectral multimode properties.

Comments
9 pages, 10 figures

Related papers

Pulse-resolved measurement of quadrature phase amplitudes of squeezed pulse trains at a repetition rate of 76 MHz

Ryuhi Okubo, Mayumi Hirano, Yun Zhang +1 more

We report pulsed homodyne detection of squeezed pulses at a repetition rate of 76 MHz. Measurement of individual pulses, which were interrogated by the correlation coefficient between adjacent pulses, was realized. A homodyne detector was constructed using a low-noise, high-speed operational amplifier; it had a usable bandwidth of 250 MHz. We observed 2.3 dB of squeezing in both the time and frequency domains.

Optics Letters•Jun 20, 2008•42 citations

High Speed Homodyne Detector for Gaussian-Modulated Coherent-State Quantum Key Distribution

Yue-Meng Chi

We developed a high speed homodyne detector in the telecommunication wavelength region for a Gaussian-modulated coherent-state quantum key distribution experiment. We are able to achieve a 100 MHz bandwidth, ultra-low electronic noise and pulse-resolved homodyne detector. The bandwidth of this homodyne detector has reached the same order of magnitude of the best homodyne detectors reported. By overcoming photodiode response functions mismatch, choosing proper laser sources, ensuring the homodyne detector linearity and stabilizing the homodyne detection system, we demonstrate that the homodyne detector has a 10 dB shot-noise-to-electronic-noise ratio in the time domain at a local oscillator of 5.4*10^8 photons/pulse at a laser repetition rate of 10 MHz. With this homodyne detector, we expect to ncrease our GMCS QKD experiment speed by 100 times, which will improve the key generation rate by 1-2 orders of magnitude.

•Jan 1, 2009•6 citations

Time-resolved pulsed homodyne detector and its application to measurement of pulsed squeezed states

Ryuhi Okubo, Mayumi Hirano, Yun Zhang +2 more

We report a pulsed homodyne detector that operates in the time domain and can measure individual pulses at a repetition rate of 76 MHz. The individuality of the measurement is interrogated by correlation coefficient between adjacent pulses. The homodyne detector is composed of a low‐noise high‐speed operational amplifier. We observed 2.3 dB of squeezing in both the time and frequency domains.

AIP conference proceedings•Jan 1, 2009•0 citations

20 MHz resonant photodetector for the homodyne measurement of picosecond pulsed squeezed light

Zhihao Li, Jun Liu, Fengjuan Guo +3 more

A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.

Optics Continuum•Feb 1, 2023•6 citations

A Simple and Robust Balanced Homodyne Detector for High-Repetition-Rate Pulsed Sources

Samuele Altilia, Edoardo Suerra, Pietro Puppi +3 more

We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.

physics.opticsCross-listedarXiv:2604.06994•Measurement Science and Technology•Apr 9, 2026•1 citation

Phase locking and homodyne detection of repetitive laser pulses

Yunxiang Wang, Yan Shihao, Meng Huo +5 more

A method to realize pulse laser phase locking and homodyne detection is proposed, which can be used in lidar and continuous variable quantum key distribution (CVQKD) systems. Theoretical analysis shows that homodyne detection of pulse laser has a sensitivity advantage of more than 4 dB over heterodyne detection. An experimental verification setup was constructed to realize phase-locking and homodyne detection of pulse lasers at repetition rates from 50 kHz to 2.4 MHz. For 320 ns signal laser pulses at 300 kHz with peak power of -65 dBm, the phase error is 8.9° (mainly limited by the chirp effect in the modulation of signal laser), and the detection signal-to-noise ratio reaches 20.2 dB. When the peak power is reduced to -75 dBm, phase locking and homodyne detection can still be achieved. Homodyne detection based on phase locking could serve as a novel weak-laser-pulse receiving method with high sensitivity and anti-interference performance.

Optics Express•Oct 31, 2020•4 citations
Homodyne detection is a phase-sensitive measurement technique, essential for the characterization of continuous-variable (CV)-encoded quantum states of light. It is a key component to the implementation of CV quantum-information protocols and benefits from operating, by design, at room temperature. However, performing high-speed quantum information processing remains a major challenge, as conventional homodyne detectors often fail to sustain pulsed operation at high repetition rates due to electronic limitations. We present wideband homodyne detectors operating at near-infrared (NIR) and telecom wavelengths, with optimized performance at repetition rates up to 150 MHz. We demonstrate their performance by resolving the pulse-by-pulse structure of squeezed states of light at telecom wavelengths while preserving their spectral multimode properties.
We developed a high speed homodyne detector in the telecommunication wavelength region for a Gaussian-modulated coherent-state quantum key distribution experiment. We are able to achieve a 100 MHz bandwidth, ultra-low electronic noise and pulse-resolved homodyne detector. The bandwidth of this homodyne detector has reached the same order of magnitude of the best homodyne detectors reported. By overcoming photodiode response functions mismatch, choosing proper laser sources, ensuring the homodyne detector linearity and stabilizing the homodyne detection system, we demonstrate that the homodyne detector has a 10 dB shot-noise-to-electronic-noise ratio in the time domain at a local oscillator of 5.4*10^8 photons/pulse at a laser repetition rate of 10 MHz. With this homodyne detector, we expect to ncrease our GMCS QKD experiment speed by 100 times, which will improve the key generation rate by 1-2 orders of magnitude.
A high-performance resonant balanced homodyne detector is a key element for the measurement of picosecond pulsed squeezed light, which is an important quantum resource in quantum-enhanced microscopic imaging. In this paper, we design and demonstrate a resonant photodetector for homodyne measurement with a maximum signal-to-noise ratio of 22.42 dB at resonant frequency of 20 MHz. Using this detector to pulsed regime, a maximum signal-to-noise ratio at resonant frequency is 10.02 dB, where a 40 dB subtraction capability at 80 MHz repetition rate of pulsed laser is obtained. With this design, the quantum noise of picosecond pulsed squeezed light is measured and the best squeezing level −1.7 dB below the shot noise level is clearly observed at 20 MHz.
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and dynamic instabilities with ultrashort pulses, our approach allows to directly amplify the photocurrent extracted at the common photodiode node without feedback loops. A theoretical model describing the detector response, noise, and pulse-to-pulse correlations is developed, providing quantitative predictions for the signal variance, signal-to-noise ratio (SNR), and inter-pulse correlations. Implemented with two matched InGaAs photodiodes illuminated by a 1030 nm mode-locked laser at 100 MHz, the detector exhibits excellent linearity and shot-noise-limited scaling of the signal variance with optical power. Optimizing the temporal integration window yields a maximum SNR of about 14 dB, while correlation measurements confirm negligible inter-pulse correlations. These results demonstrate that the proposed architecture offers a robust and simple solution for high-speed pulsed homodyne detection, suitable for quantum optics and continuous-variable quantum information applications.
A method to realize pulse laser phase locking and homodyne detection is proposed, which can be used in lidar and continuous variable quantum key distribution (CVQKD) systems. Theoretical analysis shows that homodyne detection of pulse laser has a sensitivity advantage of more than 4 dB over heterodyne detection. An experimental verification setup was constructed to realize phase-locking and homodyne detection of pulse lasers at repetition rates from 50 kHz to 2.4 MHz. For 320 ns signal laser pulses at 300 kHz with peak power of -65 dBm, the phase error is 8.9° (mainly limited by the chirp effect in the modulation of signal laser), and the detection signal-to-noise ratio reaches 20.2 dB. When the peak power is reduced to -75 dBm, phase locking and homodyne detection can still be achieved. Homodyne detection based on phase locking could serve as a novel weak-laser-pulse receiving method with high sensitivity and anti-interference performance.