Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2509.13810 · Physical Review Letters

Loss-Tolerant Detection of Squeezed States in the 2 μ m Region

K. M. Kwan, T. McRae, Jiayi Qin, Daniel W. Gould, S. Chua, J. Junker, R. Iden, V. B. Adya, M. J. Yap, Bram J. J. Slagmolen, David E. McClelland, Robert L. Ward

Published Feb 17, 2026• 1 citation
arXivHTMLPDF

Abstract

Squeezed states of light enable quantum-enhanced measurements but are limited by optical loss, particularly at 2 μm where photodiode efficiency is low. We report the first loss-tolerant, audio-band squeezed light detection at 1984 nm by using a phase-sensitive amplifier to amplify the squeezed vacuum prior to detection. This technique increases the effective detection efficiency from 74% to 95% and increases the observed squeezing from 4 to 8 dB, the highest level of squeezing observation reported at this wavelength. Additionally, the vacuum to dark-noise clearance increases, extending the effective measurement bandwidth toward lower frequencies. This approach is largely wavelength independent, extending high-fidelity quantum measurements to future gravitational-wave detectors and related quantum technologies.

DOI
10.1103/s61z-fcyp

Related papers

Amplification of 2um squeezed light

Kar Meng Kwan

Squeezed states of light enable the reduction of quantum noise in precision interferometric measurements and are routinely employed in gravitational-wave detectors. Future gravitational-wave detector upgrades based on cryogenic silicon optics are expected to operate at longer wavelengths near 1984nm, to take advantage of reduced coating thermal noise and substrate absorption. However, at these wavelengths, the observable squeezing is severely limited by optical loss, in particular the reduced quantum efficiency of available photodiodes. This thesis presents the development and experimental demonstration of a loss-tolerant detection scheme for squeezed states at 1984nm. A phase-sensitive optical parametric amplifier is implemented as a pre-amplifier, amplifying the squeezed quadrature prior to photodetection. A theoretical framework is developed to describe the generation, amplification, and detection of squeezed states in the presence of optical loss and phase noise, introducing the concept of effective detection efficiency for amplified readout. The model predicts that phase-sensitive amplification can mitigate detection loss without significantly degrading the quantum correlations of the squeezed state. Experimentally, a squeezed-light source operating at 1984nm is employed, consisting of second-harmonic generation for pump production and an optical parametric oscillator for squeezed vacuum generation. A phase-controlled optical parametric amplifier is added to the squeezed light output for amplified readout. The individual subsystems are characterized in terms of cavity parameters, escape efficiency, nonlinear gain, and control-loop performance. Amplified squeezing is demonstrated with substantially improved effective detection efficiency compared to conventional homodyne readout, despite the limited photodiode quantum efficiency. The technique also enhances noise clearance above the electronic noise floor, extending the usable measurement bandwidth. These results establish phase-sensitive amplification as a practical strategy for overcoming detection loss at long wavelengths and demonstrate its relevance for next-generation gravitational-wave detectors designed for the 2um regime.

•Jan 1, 2026•0 citations

Squeezed States of Light for Future Gravitational Wave Detectors at a Wavelength of 1550 nm

Fabian Meylahn, B. Willke, H. Vahlbruch

The generation of strongly squeezed vacuum states of light is a key technology for future ground-based gravitational wave detectors (GWDs) to reach sensitivities beyond their quantum noise limit. For some proposed observatory designs, an operating laser wavelength of 1550 nm or around 2 μm is required to enable the use of cryogenically cooled silicon test masses for thermal noise reduction. Here, we present for the first time the direct measurement of up to 11.5 dB squeezing at 1550 nm over the complete detection bandwidth of future ground-based GWDs ranging from 10 kHz down to below 1 Hz. Furthermore, we directly observe a quantum shot-noise reduction of up to (13.5±0.1) dB at megahertz frequencies. This allows us to derive a precise constraint on the absolute quantum efficiency of the photodiode used for balanced homodyne detection. These results hold important insight regarding the quantum noise reduction efficiency in future GWDs, as well as for quantum information and cryptography, where low decoherence of nonclassical states of light is also of high relevance.

Physical Review Letters•Sep 16, 2022•46 citations

Observation of Squeezed Light in the 2 μm Region

Georgia L. Mansell, T. McRae, P. A. Altin +5 more

We present the generation and detection of squeezed light in the 2 μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1 dB of squeezing and 10.5±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.

arXiv:1805.12128•Physical Review Letters•May 17, 2018•46 citations

Squeezed light at 1064 nm and 1550 nm with a nonclassical noise suppression beyond 10 dB

Moritz Mehmet

Squeezed states of light were observed for the first time in 1985.Since then they have developed into an important nonclassical tool in the field of high-precision metrology, for instance in gravitational wave detection, as well as in the field of quantum information, e.g. for teleportation and quantum cryptography.For all these applications a strong squeezing factor is beneficial.This thesis presents a new benchmark value for squeezed light from non-monolithic squeezed-light sources.By means of parametric down-conversion, squeezed states at a wavelength of 1064 nm were generated and a nonclassical noise suppression of 12.3 dB was observed.In contrast to a monolithic resonator, the resonance frequency of this squeezed-light source can be adjusted to a downstream experiment.In an additional experiment this squeezed-light source was utilized to determine the quantum efficiency of photo diodes.The applied method permits high precision since strong squeezing is sensitive to even low values of optical loss.In view of the application of squeezed light in future-generation gravitational wave detectors and quantum information science, a dedicated squeezed-light source was developed and at a wavelength of 1550 nm squeezing in the continuous-wave regime was observed for the first time.These squeezed states were employed to quantumenhance the sensitivity of a fiber-based Sagnac interferometer.Thus the compatibility of squeezing at 1550 nm with fiber-based quantum communication was demonstrated.Furthermore, upon thorough optimization of the squeezed-light generation and detection at 1550 nm, a quantum noise suppression of 12.3 dB was measured.Moreover, squeezing in the Fourier audio-band was observed for the first time.The findings presented in this thesis constitute key research towards the squeezed-light technology at 1550 nm as it is required for future gravitational wave detectors such as the recently proposed Einstein Telescope.

•Jan 1, 2012•1 citation

Squeezed vacuum phase control at 2 μm

M. J. Yap, Daniel W. Gould, T. McRae +7 more

We demonstrate phase control for vacuum-squeezed light at a 2 μm wavelength, which is a necessary technology for proposed future gravitational wave observatories. The control scheme allowed examination of noise behavior at frequencies below 1 kHz and indicated that squeezing below this frequency was limited by dark noise and scattered light. We directly measure 3.9±0.2 dB of squeezing from 2 kHz to 80 kHz and 14.2±0.3 dB of antisqueezing relative to the shot noise level. The observed maximum level of squeezing is currently limited by photodetector quantum efficiency and laser instabilities at this new wavelength for squeezed light. Accounting for all losses, we conclude the generation of 11.3 dB of squeezing at the optical parametric oscillator.

Optics Letters•Oct 31, 2019•17 citations

High-efficiency squeezed light generation for gravitational wave detectors

Moritz Mehmet, H. Vahlbruch

The engineering of strongly squeezed vacuum states of light is a key technology for the reduction of quantum noise in gravitational wave detectors. We report on the observation of up to 12.0 dB squeezed vacuum states of light at the wavelength of 1064 nm in the frequency band from 10 Hz to 100 kHz. This is the strongest squeezing reported to date within this detection band. The squeezed states were generated in a half-monolithic, standing-wave cavity optical parametric amplifier, which was resonant for the fundamental and harmonic light fields. We chose appropriate reflectivities to obtain a significant reduction of the required pump power, which was 8.6 mW only. Our analysis revealed that the residual measurement phase noise was smaller than 3.5 mrad rms and that the squeezed light source provided up to 14 dB of squeezing for a downstream application. The experiment was electronically stabilized in all relevant degrees of freedom, demonstrating the applicability of the linear, doubly resonant cavity topology for current and future gravitational wave detectors.

Classical and Quantum Gravity•Nov 27, 2018•48 citations
Squeezed states of light enable quantum-enhanced measurements but are limited by optical loss, particularly at 2 μm where photodiode efficiency is low. We report the first loss-tolerant, audio-band squeezed light detection at 1984 nm by using a phase-sensitive amplifier to amplify the squeezed vacuum prior to detection. This technique increases the effective detection efficiency from 74% to 95% and increases the observed squeezing from 4 to 8 dB, the highest level of squeezing observation reported at this wavelength. Additionally, the vacuum to dark-noise clearance increases, extending the effective measurement bandwidth toward lower frequencies. This approach is largely wavelength independent, extending high-fidelity quantum measurements to future gravitational-wave detectors and related quantum technologies.
Squeezed states of light enable the reduction of quantum noise in precision interferometric measurements and are routinely employed in gravitational-wave detectors. Future gravitational-wave detector upgrades based on cryogenic silicon optics are expected to operate at longer wavelengths near 1984nm, to take advantage of reduced coating thermal noise and substrate absorption. However, at these wavelengths, the observable squeezing is severely limited by optical loss, in particular the reduced quantum efficiency of available photodiodes. This thesis presents the development and experimental demonstration of a loss-tolerant detection scheme for squeezed states at 1984nm. A phase-sensitive optical parametric amplifier is implemented as a pre-amplifier, amplifying the squeezed quadrature prior to photodetection. A theoretical framework is developed to describe the generation, amplification, and detection of squeezed states in the presence of optical loss and phase noise, introducing the concept of effective detection efficiency for amplified readout. The model predicts that phase-sensitive amplification can mitigate detection loss without significantly degrading the quantum correlations of the squeezed state. Experimentally, a squeezed-light source operating at 1984nm is employed, consisting of second-harmonic generation for pump production and an optical parametric oscillator for squeezed vacuum generation. A phase-controlled optical parametric amplifier is added to the squeezed light output for amplified readout. The individual subsystems are characterized in terms of cavity parameters, escape efficiency, nonlinear gain, and control-loop performance. Amplified squeezing is demonstrated with substantially improved effective detection efficiency compared to conventional homodyne readout, despite the limited photodiode quantum efficiency. The technique also enhances noise clearance above the electronic noise floor, extending the usable measurement bandwidth. These results establish phase-sensitive amplification as a practical strategy for overcoming detection loss at long wavelengths and demonstrate its relevance for next-generation gravitational-wave detectors designed for the 2um regime.
The generation of strongly squeezed vacuum states of light is a key technology for future ground-based gravitational wave detectors (GWDs) to reach sensitivities beyond their quantum noise limit. For some proposed observatory designs, an operating laser wavelength of 1550 nm or around 2 μm is required to enable the use of cryogenically cooled silicon test masses for thermal noise reduction. Here, we present for the first time the direct measurement of up to 11.5 dB squeezing at 1550 nm over the complete detection bandwidth of future ground-based GWDs ranging from 10 kHz down to below 1 Hz. Furthermore, we directly observe a quantum shot-noise reduction of up to (13.5±0.1) dB at megahertz frequencies. This allows us to derive a precise constraint on the absolute quantum efficiency of the photodiode used for balanced homodyne detection. These results hold important insight regarding the quantum noise reduction efficiency in future GWDs, as well as for quantum information and cryptography, where low decoherence of nonclassical states of light is also of high relevance.
We present the generation and detection of squeezed light in the 2 μm wavelength region. This experiment is a crucial step in realizing the quantum noise reduction techniques that will be required for future generations of gravitational-wave detectors. Squeezed vacuum is generated via degenerate optical parametric oscillation from a periodically poled potassium titanyl phosphate crystal, in a dual resonant cavity. The experiment uses a frequency stabilized 1984 nm thulium fiber laser, and squeezing is detected using balanced homodyne detection with extended InGaAs photodiodes. We have measured 4.0±0.1 dB of squeezing and 10.5±0.5 dB of antisqueezing relative to the shot noise level in the audio frequency band, limited by photodiode quantum efficiency. The inferred squeezing level directly after the optical parametric oscillator, after accounting for known losses and phase noise, is 10.7 dB.
Squeezed states of light were observed for the first time in 1985.Since then they have developed into an important nonclassical tool in the field of high-precision metrology, for instance in gravitational wave detection, as well as in the field of quantum information, e.g. for teleportation and quantum cryptography.For all these applications a strong squeezing factor is beneficial.This thesis presents a new benchmark value for squeezed light from non-monolithic squeezed-light sources.By means of parametric down-conversion, squeezed states at a wavelength of 1064 nm were generated and a nonclassical noise suppression of 12.3 dB was observed.In contrast to a monolithic resonator, the resonance frequency of this squeezed-light source can be adjusted to a downstream experiment.In an additional experiment this squeezed-light source was utilized to determine the quantum efficiency of photo diodes.The applied method permits high precision since strong squeezing is sensitive to even low values of optical loss.In view of the application of squeezed light in future-generation gravitational wave detectors and quantum information science, a dedicated squeezed-light source was developed and at a wavelength of 1550 nm squeezing in the continuous-wave regime was observed for the first time.These squeezed states were employed to quantumenhance the sensitivity of a fiber-based Sagnac interferometer.Thus the compatibility of squeezing at 1550 nm with fiber-based quantum communication was demonstrated.Furthermore, upon thorough optimization of the squeezed-light generation and detection at 1550 nm, a quantum noise suppression of 12.3 dB was measured.Moreover, squeezing in the Fourier audio-band was observed for the first time.The findings presented in this thesis constitute key research towards the squeezed-light technology at 1550 nm as it is required for future gravitational wave detectors such as the recently proposed Einstein Telescope.
We demonstrate phase control for vacuum-squeezed light at a 2 μm wavelength, which is a necessary technology for proposed future gravitational wave observatories. The control scheme allowed examination of noise behavior at frequencies below 1 kHz and indicated that squeezing below this frequency was limited by dark noise and scattered light. We directly measure 3.9±0.2 dB of squeezing from 2 kHz to 80 kHz and 14.2±0.3 dB of antisqueezing relative to the shot noise level. The observed maximum level of squeezing is currently limited by photodetector quantum efficiency and laser instabilities at this new wavelength for squeezed light. Accounting for all losses, we conclude the generation of 11.3 dB of squeezing at the optical parametric oscillator.
The engineering of strongly squeezed vacuum states of light is a key technology for the reduction of quantum noise in gravitational wave detectors. We report on the observation of up to 12.0 dB squeezed vacuum states of light at the wavelength of 1064 nm in the frequency band from 10 Hz to 100 kHz. This is the strongest squeezing reported to date within this detection band. The squeezed states were generated in a half-monolithic, standing-wave cavity optical parametric amplifier, which was resonant for the fundamental and harmonic light fields. We chose appropriate reflectivities to obtain a significant reduction of the required pump power, which was 8.6 mW only. Our analysis revealed that the residual measurement phase noise was smaller than 3.5 mrad rms and that the squeezed light source provided up to 14 dB of squeezing for a downstream application. The experiment was electronically stabilized in all relevant degrees of freedom, demonstrating the applicability of the linear, doubly resonant cavity topology for current and future gravitational wave detectors.