Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2508.01026 · Optica Quantum

Ultimate resolution limits in coherent anti-Stokes Raman scattering imaging

Giacomo Sorelli, Manuel Gessner, Frank Schlawin

Published May 27, 2026• 4 citations
arXivHTMLPDF

Abstract

Coherent anti-Stokes Raman scattering is a widely used imaging technique that provides chemical contrast without the need for labels, making it an extremely valuable tool in physics, chemistry, and biology. In this work, we explore its fundamental precision limits by applying tools from quantum information theory. We identify optimal measurement strategies and show that spatial mode demultiplexing–a technique already accessible in current experimental setups–can achieve these quantum limits and, in many situations, improve the sensitivity of conventional intensity measurements. Building on this, we introduce an advanced imaging scheme based on vortex beams, which we predict to enhance the image information in the final quantum state of light and thereby lead to even higher resolution and sensitivity. These findings establish a clear path for enhancing nonlinear imaging techniques using concepts from quantum science, bridging the gap between established microscopy methods and the emerging capabilities of quantum technologies.

DOI
10.1364/opticaq.585589

Related papers

Quantum-optimal nonlinear microscopy with classical light

Joshua L. Reynolds, S. C. Burd, Tzu-Chieh Yen +3 more

Nonlinear optical processes are used in biological microscopy to surpass the diffraction limit on resolution, image deeper into brain tissues, and identify biomolecules without exogenous labels. These techniques typically require high optical intensities to increase the strength of the nonlinear interactions, which can perturb native biochemistry and damage or kill living samples. Stimulated Raman scattering (SRS) microscopy visualizes the spatial distribution of molecules using a nonlinear interaction between light and chemically specific molecular vibrations. However, the detection of biomolecules at low concentrations is limited by the total photon dose that can be applied before photodamage alters the sample, and photon shot noise sets the minimum achievable noise floor for most microscopes. Here we demonstrate a cavity-enhanced SRS microscope that is more sensitive than an equivalent conventional SRS microscope by up to 8.3(7) dB in spectroscopy and 8.6(1) dB in cell imaging. These results approach quantum limits on sensitivity and demonstrate that quantum states of light are sufficient but not necessary to enhance the sensitivity of microscopy techniques that are limited by photodamage.

arXiv:2512.04328•Dec 3, 2025•2 citations

Theory of quantum-enhanced stimulated Raman scattering

Frank Schlawin, Manuel Gessner

Abstract Stimulated Raman scattering (SRS) is a powerful technique for imaging and spectroscopy, in particular in chemistry and biology. By introducing a full quantum description, we determine the ultimate quantum limits of precision and optimal strategies to approach them within the rigorous framework offered by quantum metrology. This approach reveals optimal uses of squeezed states, and the possibility of enhancing the resolution beyond recent experiments. Our work establishes a basis for approaching quantum precision limits in SRS and integrating nonlinear spectroscopy and imaging with emerging quantum technologies.

arXiv:2502.19344•Quantum Science and Technology•Mar 11, 2026•6 citations

Nonlinear Optics Approaches Towards Subdiffraction Resolution in CARS Imaging

Klaus J. Boller, Willem P. Beeker, Carsten Cleff +6 more

In theoretical investigations, we review several nonlinear optical approaches towards subdiffraction-limited resolution in label-free imaging via coherent anti-Stokes Raman scattering (CARS). Using a density matrix model and numerical integration, we investigate various level schemes and combinations of the light fields that induce CARS along with additional control laser fields. As the key to techniques that gain far-field resolution below the diffraction limit, we identify the inhibition of the buildup of vibrational molecular coherence via saturation or depletion of population (Beeker et al. Opt Express 17:22632–22638, 2009) or the generation of Stark broadening and spatially dependent Rabi sideband generation (Beeker et al. Phys Rev A 81(1), 2010). Depending on the coherence and population decay rates offered by a particular molecular energy level scheme, we identify various different regimes. In the first case, where an additional state (called the control state) and a vibrational state are able to rapidly exchange population via incoherent processes, a prepopulation of the upper vibrational state inhibits the buildup of vibrational coherence. With increasing control laser intensity, this suppresses CARS emission via an incoherent, saturation type of nonlinear process. Using an intense, donut-shaped control laser beam, similar to stimulated emission depletion (STED) microscopy, this can suppress CARS emission from all sample locations except within a subdiffraction-sized range around the central node. Scanning the control beams across the sample provides subdiffraction-limited resolution imaging. An alternative, which does not require a rapid exchange of population with the control state, applies a control beam that only partially depletes the vibrational ground state. Thereby, a CARS point spread function containing a subdiffraction-limited component is generated. Subdiffraction images can then be retrieved through deconvolution. Further approaches are based on the coherent, nonlinear, resonant response of the sample. In this case, CARS signal depletion by Stark splitting of the weakly populated upper vibrational state or the observation of spatially dependent Rabi oscillation may increase the resolution beyond the diffraction limit.

Neuromethods•Jan 1, 2014•2 citations

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•14 citations

Ground-state depletion for subdiffraction-limited spatial resolution in coherent anti-Stokes Raman scattering microscopy

Carsten Cleff, Petra Groß, Carsten Fallnich +6 more

We theoretically investigate ground-state depletion for subdiffraction-limited spatial resolution in coherent anti-Stokes Raman scattering (CARS) microscopy. We propose a scheme based on ground-state depopulation, which is achieved via a control laser light field incident prior to the CARS excitation light fields. This ground-state depopulation results in a reduced CARS signal generation. With an appropriate choice of spatial beam profiles, the scheme can be used to increase the spatial resolution. Based on the density matrix formalism we calculate the CARS signal generation and find a CARS signal suppression by 75$%$ due to ground-state depletion with a single control light field and by using two control light fields the CARS signal suppression can be enhanced to 94$%$. Additional control light fields will enhance the CARS suppression even further. In case of a single control light field we calculate resulting CARS images using a computer-generated test image including quantum and detector noise and show that the background from the limited CARS suppression can be removed by calculating difference images, yielding subdiffraction-limited resolution where the resolution achievable depends only on the intensity used.

Physical Review A•Aug 16, 2012•36 citations

Stimulated-emission pumping enabling sub-diffraction-limited spatial resolution in coherent anti-Stokes Raman scattering microscopy

Carsten Cleff, Petra Groß, Carsten Fallnich +6 more

We present a theoretical investigation of stimulated emission pumping to achieve sub-diffraction-limited spatial resolution in coherent anti-Stokes Raman scattering (CARS) microscopy. A pair of control light fields is used to prepopulate the Raman state involved in the CARS process prior to the CARS signal generation. Efficient prepopulation is achieved by employing a path via an electronic or vibrational state. Thereby, the buildup of a coherence between the ground and Raman state during irradiation by the light fields for CARS signal generation is prevented, resulting in the suppression of the CARS intensity by more than 99.8$%$. Two-dimensional spatial excitation profiles have been calculated using donut-shaped spatial profiles for the control light fields, thus, an intensity-dependent narrowing of the CARS excitation profiles below the diffraction limit. Using computer-generated test images we demonstrate a resolution beyond the diffraction limit for CARS microscopy, which is scalable by the control light field intensity, similar to stimulated emission depletion microscopy.

Physical Review A•Mar 25, 2013•26 citations
Coherent anti-Stokes Raman scattering is a widely used imaging technique that provides chemical contrast without the need for labels, making it an extremely valuable tool in physics, chemistry, and biology. In this work, we explore its fundamental precision limits by applying tools from quantum information theory. We identify optimal measurement strategies and show that spatial mode demultiplexing–a technique already accessible in current experimental setups–can achieve these quantum limits and, in many situations, improve the sensitivity of conventional intensity measurements. Building on this, we introduce an advanced imaging scheme based on vortex beams, which we predict to enhance the image information in the final quantum state of light and thereby lead to even higher resolution and sensitivity. These findings establish a clear path for enhancing nonlinear imaging techniques using concepts from quantum science, bridging the gap between established microscopy methods and the emerging capabilities of quantum technologies.
Nonlinear optical processes are used in biological microscopy to surpass the diffraction limit on resolution, image deeper into brain tissues, and identify biomolecules without exogenous labels. These techniques typically require high optical intensities to increase the strength of the nonlinear interactions, which can perturb native biochemistry and damage or kill living samples. Stimulated Raman scattering (SRS) microscopy visualizes the spatial distribution of molecules using a nonlinear interaction between light and chemically specific molecular vibrations. However, the detection of biomolecules at low concentrations is limited by the total photon dose that can be applied before photodamage alters the sample, and photon shot noise sets the minimum achievable noise floor for most microscopes. Here we demonstrate a cavity-enhanced SRS microscope that is more sensitive than an equivalent conventional SRS microscope by up to 8.3(7) dB in spectroscopy and 8.6(1) dB in cell imaging. These results approach quantum limits on sensitivity and demonstrate that quantum states of light are sufficient but not necessary to enhance the sensitivity of microscopy techniques that are limited by photodamage.
Abstract Stimulated Raman scattering (SRS) is a powerful technique for imaging and spectroscopy, in particular in chemistry and biology. By introducing a full quantum description, we determine the ultimate quantum limits of precision and optimal strategies to approach them within the rigorous framework offered by quantum metrology. This approach reveals optimal uses of squeezed states, and the possibility of enhancing the resolution beyond recent experiments. Our work establishes a basis for approaching quantum precision limits in SRS and integrating nonlinear spectroscopy and imaging with emerging quantum technologies.
In theoretical investigations, we review several nonlinear optical approaches towards subdiffraction-limited resolution in label-free imaging via coherent anti-Stokes Raman scattering (CARS). Using a density matrix model and numerical integration, we investigate various level schemes and combinations of the light fields that induce CARS along with additional control laser fields. As the key to techniques that gain far-field resolution below the diffraction limit, we identify the inhibition of the buildup of vibrational molecular coherence via saturation or depletion of population (Beeker et al. Opt Express 17:22632–22638, 2009) or the generation of Stark broadening and spatially dependent Rabi sideband generation (Beeker et al. Phys Rev A 81(1), 2010). Depending on the coherence and population decay rates offered by a particular molecular energy level scheme, we identify various different regimes. In the first case, where an additional state (called the control state) and a vibrational state are able to rapidly exchange population via incoherent processes, a prepopulation of the upper vibrational state inhibits the buildup of vibrational coherence. With increasing control laser intensity, this suppresses CARS emission via an incoherent, saturation type of nonlinear process. Using an intense, donut-shaped control laser beam, similar to stimulated emission depletion (STED) microscopy, this can suppress CARS emission from all sample locations except within a subdiffraction-sized range around the central node. Scanning the control beams across the sample provides subdiffraction-limited resolution imaging. An alternative, which does not require a rapid exchange of population with the control state, applies a control beam that only partially depletes the vibrational ground state. Thereby, a CARS point spread function containing a subdiffraction-limited component is generated. Subdiffraction images can then be retrieved through deconvolution. Further approaches are based on the coherent, nonlinear, resonant response of the sample. In this case, CARS signal depletion by Stark splitting of the weakly populated upper vibrational state or the observation of spatially dependent Rabi oscillation may increase the resolution beyond the diffraction limit.
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.
We theoretically investigate ground-state depletion for subdiffraction-limited spatial resolution in coherent anti-Stokes Raman scattering (CARS) microscopy. We propose a scheme based on ground-state depopulation, which is achieved via a control laser light field incident prior to the CARS excitation light fields. This ground-state depopulation results in a reduced CARS signal generation. With an appropriate choice of spatial beam profiles, the scheme can be used to increase the spatial resolution. Based on the density matrix formalism we calculate the CARS signal generation and find a CARS signal suppression by 75% due to ground-state depletion with a single control light field and by using two control light fields the CARS signal suppression can be enhanced to 94%. Additional control light fields will enhance the CARS suppression even further. In case of a single control light field we calculate resulting CARS images using a computer-generated test image including quantum and detector noise and show that the background from the limited CARS suppression can be removed by calculating difference images, yielding subdiffraction-limited resolution where the resolution achievable depends only on the intensity used.
We present a theoretical investigation of stimulated emission pumping to achieve sub-diffraction-limited spatial resolution in coherent anti-Stokes Raman scattering (CARS) microscopy. A pair of control light fields is used to prepopulate the Raman state involved in the CARS process prior to the CARS signal generation. Efficient prepopulation is achieved by employing a path via an electronic or vibrational state. Thereby, the buildup of a coherence between the ground and Raman state during irradiation by the light fields for CARS signal generation is prevented, resulting in the suppression of the CARS intensity by more than 99.8%. Two-dimensional spatial excitation profiles have been calculated using donut-shaped spatial profiles for the control light fields, thus, an intensity-dependent narrowing of the CARS excitation profiles below the diffraction limit. Using computer-generated test images we demonstrate a resolution beyond the diffraction limit for CARS microscopy, which is scalable by the control light field intensity, similar to stimulated emission depletion microscopy.