Measuring spatial coherence of quantum and classical light with an ultrastable monolithic interferometer

Edoardo Suerra, M. Siano, B. Paroli, Samuele Altilia, M. A. C. Potenza, Matteo G. A. Paris, S. Cialdi

Published Dec 8, 2025• 0 citations
arXivHTMLPDF

Abstract

Abstract We describe a monolithic interferometer for spatial coherence measurements of both classical and quantum light sources. The design enables measurements on both a PDC-based quantum source and a classical thermal source, using two identical calcite crystals to control beam alignment via birefringence. The monolithic structure ensures inherent stability. Spatial coherence is measured through temporal interferograms and spectral analysis, with both methods showing close agreement with theoretical predictions. The system is robust and performs reliably for both quantum and classical light. Its design enables automated, rapid coherence measurements across different source types.

DOI
10.1088/2040-8986/ae2935

Related papers

Monolithic atom interferometry

Johannes Fiedler, Kim Lefmann, Wolf von Klitzing +1 more

Atom and, more recently, molecule interferometers are used in fundamental research and industrial applications. Most atom interferometers rely on gratings made from laser beams, which can provide high precision, but cannot reach very short wavelengths and require complex laser systems to function. Contrary to this, simple monolithic interferometers cut from single crystals offer (sub) nanometer wavelengths with an extreme level of stability and robustness. Such devices were conceived and demonstrated several decades ago for neutrons and electrons. Here, we propose a monolithic design for a thermal-beam molecule interferometer based on (quantum) reflection. We show, as an example, how a reflective, monolithic interferometer (Mach-Zehnder type) can be realized for a helium beam using $\mathrm{Si}(111)\text{\ensuremath{-}}\mathrm{H}(1\ifmmode\times\else\texttimes\fi{}1)$ surfaces, which have previously been demonstrated to act as very robust and stable diffractive mirrors for neutral helium atoms.

arXiv:2307.02285•Physical Review A•Aug 7, 2023•6 citations

Interference of Light in a Michelson-Morley Interferometer: A Quantum Optical Approach

Øystein Langangen, Asle Heide Vaskinn, B.-S. Skagerstam

The temporal coherence interference properties of light as revealed by single detector intensity measurements in a Michelson-Morley interferometer (MMI) is often described in terms of classical optics. We show, in a pedagogical manner, how such features of light also can be understood in terms of a more general quantum-optics framework. If a thermal reference source is used in the MMI local oscillator port in combination with a thermal source in the signal port, the interference pattern revealed by single detector intensity measurements shows a distinctive dependence on the differences in the temperature of the two sources. A related method has actually been used to perform high-precision measurements of the cosmic microwave background radiation. The general quantum-optics framework allows us to consider any initialquantum state. As an example, we consider the interference of single photons as a tool to determine the peak angular-frequency of a single-photon pulse interfering with a single-photon reference pulse. A similar consideration for laser pulses, in terms of coherent states, leads to a different response in the detector. The MMI experimental setup is therefore an example of an optical device where one, in terms of intensity measurements, can exhibit the difference between classical and quantum-mechanical light.

arXiv:1102.4324•International Journal of Optics•Jan 1, 2012•3 citations

A monolithic interferometer for high-sensitive strictly-local detection of orbital angular momentum states of light

M. Siano, B. Paroli, S. Cialdi +4 more

We propose an innovative monolithic interferometer to distinguish the topological charge of radiation carrying orbital angular momentum. Remarkably, our method requires to access only a small portion of the entire wavefront. The proposed scheme relies on a monolithic birefringent crystal, and as such it is intrinsically stable and does not require any feedback or thermal drift compensation. An experimental setup has been realized to prove the effectiveness of the proposed method down to the photon counting regime.

arXiv:2301.07489•Jan 18, 2023•0 citations

Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry

Jesse Crawford, Denis Dolzhenko, Michael Keach +6 more

Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

arXiv:2301.07042•Optics Express•Sep 13, 2023•18 citations

Local discrimination of orbital angular momentum in entangled states

S. Cialdi, Edoardo Suerra, Samuele Altilia +5 more

In this paper, we address the use of a calcite crystal-based local detector for the discrimination of the orbital angular momentum of quantum radiation produced by parametric down-conversion, using only a portion of the beam. Specifically, we propose and experimentally demonstrate that discrimination can be achieved by exploiting the introduction of a precise and controlled spatial shift between two replicas of the state within the crystals. This approach utilizes a robust and intrinsically stable monolithic configuration, obviating the need for feedback mechanisms or thermal drift compensation. Our method offers a promising avenue for enhancing the reliability and efficiency of quantum communication systems, and we believe that this technology could significantly advance the development of quantum communication techniques, where information encoding is based on orbital angular momentum, or spatially distributed orbital angular momentum detection.

arXiv:2309.00295•Physical Review A•Oct 1, 2024•1 citation

Quantum optical coherence tomography with true thermal light

Yanhua Zhai, Xi-Hao Chen, Jian-Ling Zhao +2 more

We report a proof-of-principle experiment demonstrating quantum optical coherence tomography with a true thermal light source. The axial distance between two mirrors has been measured. Although the resolution is as yet low the method could conceivably be used to measure the structure of macroscopic objects.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Aug 1, 2007•1 citation
Abstract We describe a monolithic interferometer for spatial coherence measurements of both classical and quantum light sources. The design enables measurements on both a PDC-based quantum source and a classical thermal source, using two identical calcite crystals to control beam alignment via birefringence. The monolithic structure ensures inherent stability. Spatial coherence is measured through temporal interferograms and spectral analysis, with both methods showing close agreement with theoretical predictions. The system is robust and performs reliably for both quantum and classical light. Its design enables automated, rapid coherence measurements across different source types.
Atom and, more recently, molecule interferometers are used in fundamental research and industrial applications. Most atom interferometers rely on gratings made from laser beams, which can provide high precision, but cannot reach very short wavelengths and require complex laser systems to function. Contrary to this, simple monolithic interferometers cut from single crystals offer (sub) nanometer wavelengths with an extreme level of stability and robustness. Such devices were conceived and demonstrated several decades ago for neutrons and electrons. Here, we propose a monolithic design for a thermal-beam molecule interferometer based on (quantum) reflection. We show, as an example, how a reflective, monolithic interferometer (Mach-Zehnder type) can be realized for a helium beam using $\mathrm{Si}(111)\text{\ensuremath{-}}\mathrm{H}(1\ifmmode\times\else\texttimes\fi{}1)$ surfaces, which have previously been demonstrated to act as very robust and stable diffractive mirrors for neutral helium atoms.
The temporal coherence interference properties of light as revealed by single detector intensity measurements in a Michelson-Morley interferometer (MMI) is often described in terms of classical optics. We show, in a pedagogical manner, how such features of light also can be understood in terms of a more general quantum-optics framework. If a thermal reference source is used in the MMI local oscillator port in combination with a thermal source in the signal port, the interference pattern revealed by single detector intensity measurements shows a distinctive dependence on the differences in the temperature of the two sources. A related method has actually been used to perform high-precision measurements of the cosmic microwave background radiation. The general quantum-optics framework allows us to consider any initialquantum state. As an example, we consider the interference of single photons as a tool to determine the peak angular-frequency of a single-photon pulse interfering with a single-photon reference pulse. A similar consideration for laser pulses, in terms of coherent states, leads to a different response in the detector. The MMI experimental setup is therefore an example of an optical device where one, in terms of intensity measurements, can exhibit the difference between classical and quantum-mechanical light.
We propose an innovative monolithic interferometer to distinguish the topological charge of radiation carrying orbital angular momentum. Remarkably, our method requires to access only a small portion of the entire wavefront. The proposed scheme relies on a monolithic birefringent crystal, and as such it is intrinsically stable and does not require any feedback or thermal drift compensation. An experimental setup has been realized to prove the effectiveness of the proposed method down to the photon counting regime.
Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.
In this paper, we address the use of a calcite crystal-based local detector for the discrimination of the orbital angular momentum of quantum radiation produced by parametric down-conversion, using only a portion of the beam. Specifically, we propose and experimentally demonstrate that discrimination can be achieved by exploiting the introduction of a precise and controlled spatial shift between two replicas of the state within the crystals. This approach utilizes a robust and intrinsically stable monolithic configuration, obviating the need for feedback mechanisms or thermal drift compensation. Our method offers a promising avenue for enhancing the reliability and efficiency of quantum communication systems, and we believe that this technology could significantly advance the development of quantum communication techniques, where information encoding is based on orbital angular momentum, or spatially distributed orbital angular momentum detection.