Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2506.17423 · Physical Review Letters

Liquid-Nitrogen-Cooled 40 Ca + Ion Optical Clock with a Systematic Uncertainty of 4.4 × 10 − 19

Bao-Lin 宝林 Zhang 张, Zixiao Ma, Yao Huang, Hui-Li Han, Ru-ming Hu, Yuzhuo Wang, Hua-qing Zhang, Li-Yan Tang, Ting-Yun Shi, Guan Hua, Kelin Gao

Published Dec 22, 2025• 34 citations
arXivHTMLPDF

Abstract

We report a single-ion optical clock based on the 4S_{1/2}→3D_{5/2} transition of the ^{40}Ca^{+} ion, operated in a liquid nitrogen cryogenic environment, achieving a total systematic uncertainty of 4.4×10^{-19}. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation, and 3D sideband cooling to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the ^{40}Ca^{+} clock transition to be 14.345(15) Hz/mT^{2}, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.

DOI
10.1103/vngc-c1xv

Related papers

Progress on the development of optical clocks based on a single trapped Ca + ion

Hua Guan, 杨万里, Kelin Gao

This paper reports on the development of a single-ion optical clock based on the 4S1/2→3D5/2transition of Ca+. Operating in a liquid nitrogen cryogenic environment, the clock achieves a total systematic uncertainty of 4.4×10-19. Key improvements include a refined blackbody radiation evaluation, 3D sideband cooling to reduce the second-order Doppler shift, and precise determination of the quadratic Zeeman coefficient. Additionally, a transportable Ca+optical clock operating at room temperature is presented, with a total systematic uncertainty of 4.8×10-18and a stability of 5.5×10-18at one day of averaging, supported by magnetic shielding and a high-performance ultra-stable laser.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18

Yao Huang, Baolin Zhang, Mengyan Zeng +7 more

We present a liquid-nitrogen-cooled $\mathrm{Ca}$${}^{+}$ optical clock with an overall systematic uncertainty of $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. In contrast to the room-temperature $\mathrm{Ca}$${}^{+}$ optical clock that we have reported previously, the cryogenic black-body radiation (BBR) shield in vacuum is cooled to $82\ifmmode\pm\else\textpm\fi{}5$ K using liquid nitrogen. We also implement an ion trap with a reduced heating rate and improved laser cooling. This allows the ion temperature to fall to the Doppler-cooling limit during the clock operation and the systematic uncertainty associated with the secular (thermal) motion of the ion is reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The uncertainty arising from the probe laser light shift and the servo error is also reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ and $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two is determined with a fractional statistical uncertainty of $7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The differential BBR shift is used to calculate the static differential polarizability and the result is found to be in excellent agreement with our previous measurement using a different method. This work suggests that the BBR shift of optical clocks can be suppressed well in a liquid-nitrogen environment. Systems similar to what is presented here can also be used to suppress the BBR shift significantly in other types of optical clocks, such as $\mathrm{Yb}$${}^{+}$, $\mathrm{Sr}$${}^{+}$, $\mathrm{Yb}$, Sr, etc.

arXiv:2103.08913•Physical Review Applied•Mar 15, 2022•91 citations

A cryogenic radio-frequency ion trap for a 40Ca+ optical clock

Mengyan Zeng, Yao 垚 Huang 黄, Baolin 宝林 Zhang 张 +6 more

A liquid-nitrogen cryogenic 40Ca+ optical clock is presented that is designed to greatly reduce the blackbody radiation (BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container, keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container; the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container; and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum, which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks.

Chinese Physics B•Mar 28, 2023•2 citations

Evaluation of the performance of a ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ optical clock

Kaifeng Cui, Sijia Chao, Chenglong Sun +6 more

We report the evaluation of the systematic shifts and the total uncertainty of an ${}^{27}\textrm{Al}^+$ optical clock sympathetically cooled by a ${}^{40}\textrm{Ca}^+$ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the ${}^{27}\textrm{Al}^+$ ion, the time dilation shift of the secular motion of our ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ clock is smaller than the shift of a ${}^{25}\textrm{Mg}^+ - {}^{27}\textrm{Al}^+$ clock. The total systematic uncertainty of our ${}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+$ quantum logic clock has been estimated to be $7.6 \times 10^{-18}$, which was mainly limited by the uncertainty of the quadratic Zeeman shift.

•Dec 10, 2020•0 citations

Progress on the 40Ca+ ion optical clock*

Baolin Zhang, Yao Huang, Huaqing Zhang +4 more

Progress of the 40Ca+ ion optical clock based on the 42S1/2 – 3d 2D5/2 electric quadrupole transition is reported. By setting the drive frequency to the “magic” frequency Ω 0, the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10−19 level. By precisely measuring the differential static scalar polarizability Δα 0, the uncertainty due to the blackbody radiation (BBR) shift (coefficient) is reduced to the 10−19 level. With the help of a second-order integrating servo algorithm, the uncertainty due to the servo error is reduced to the 10−18 level. The total fractional uncertainty of the 40Ca+ ion optical clock is then improved to 2.2× 10−17, whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations. The state preparation is introduced together with improvements in the pulse sequence, and furthermore, a better signal to noise ratio (SNR) and less dead time are achieved. The clock stability of a single clock is improved to 4.8 × 10 − 15 / τ ( in seconds ) .

Chinese Physics B•May 19, 2020•18 citations

Optical frequency standard based on a single 40Ca+

Kelin Gao

Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.

Chinese Science Bulletin•Mar 1, 2013•9 citations
We report a single-ion optical clock based on the 4S_{1/2}→3D_{5/2} transition of the ^{40}Ca^{+} ion, operated in a liquid nitrogen cryogenic environment, achieving a total systematic uncertainty of 4.4×10^{-19}. We employ a refined temperature evaluation scheme to reduce the frequency uncertainty due to blackbody radiation, and 3D sideband cooling to minimize the second-order Doppler shift. We have precisely determined the average Zeeman coefficient of the ^{40}Ca^{+} clock transition to be 14.345(15) Hz/mT^{2}, thereby significantly reducing the quadratic Zeeman shift uncertainty. Moreover, the cryogenic environment enables the lowest reported heating rate due to ambient electric field noise in trapped-ion optical clocks.
This paper reports on the development of a single-ion optical clock based on the 4S1/2→3D5/2transition of Ca+. Operating in a liquid nitrogen cryogenic environment, the clock achieves a total systematic uncertainty of 4.4×10-19. Key improvements include a refined blackbody radiation evaluation, 3D sideband cooling to reduce the second-order Doppler shift, and precise determination of the quadratic Zeeman coefficient. Additionally, a transportable Ca+optical clock operating at room temperature is presented, with a total systematic uncertainty of 4.8×10-18and a stability of 5.5×10-18at one day of averaging, supported by magnetic shielding and a high-performance ultra-stable laser.
We present a liquid-nitrogen-cooled Ca\mathrm{Ca}Ca+{}^{+}+ optical clock with an overall systematic uncertainty of $3.0\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. In contrast to the room-temperature Ca\mathrm{Ca}Ca+{}^{+}+ optical clock that we have reported previously, the cryogenic black-body radiation (BBR) shield in vacuum is cooled to $82\ifmmode\pm\else\textpm\fi{}5$ K using liquid nitrogen. We also implement an ion trap with a reduced heating rate and improved laser cooling. This allows the ion temperature to fall to the Doppler-cooling limit during the clock operation and the systematic uncertainty associated with the secular (thermal) motion of the ion is reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The uncertainty arising from the probe laser light shift and the servo error is also reduced to $<1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ and $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$ with the hyper-Ramsey method and the higher-order servo algorithm, respectively. By comparing the output frequency of the cryogenic clock to that of a room-temperature clock, the differential BBR shift between the two is determined with a fractional statistical uncertainty of $7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. The differential BBR shift is used to calculate the static differential polarizability and the result is found to be in excellent agreement with our previous measurement using a different method. This work suggests that the BBR shift of optical clocks can be suppressed well in a liquid-nitrogen environment. Systems similar to what is presented here can also be used to suppress the BBR shift significantly in other types of optical clocks, such as Yb\mathrm{Yb}Yb+{}^{+}+, Sr\mathrm{Sr}Sr+{}^{+}+, Yb\mathrm{Yb}Yb, Sr, etc.
A liquid-nitrogen cryogenic 40Ca+ optical clock is presented that is designed to greatly reduce the blackbody radiation (BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container, keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container; the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container; and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum, which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks.
Evaluation of the performance of a 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ optical clock
We report the evaluation of the systematic shifts and the total uncertainty of an 27Al+{}^{27}\textrm{Al}^+27Al+ optical clock sympathetically cooled by a 40Ca+{}^{40}\textrm{Ca}^+40Ca+ ion. Due to its relatively low Doppler cooling limit and the suitability of its mass ratio to the 27Al+{}^{27}\textrm{Al}^+27Al+ ion, the time dilation shift of the secular motion of our 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ clock is smaller than the shift of a 25Mg+−27Al+{}^{25}\textrm{Mg}^+ - {}^{27}\textrm{Al}^+25Mg+−27Al+ clock. The total systematic uncertainty of our 40Ca+−27Al+{}^{40}\textrm{Ca}^+ - {}^{27}\textrm{Al}^+40Ca+−27Al+ quantum logic clock has been estimated to be 7.6×10−187.6 \times 10^{-18}7.6×10−18, which was mainly limited by the uncertainty of the quadratic Zeeman shift.
Progress of the 40Ca+ ion optical clock based on the 42S1/2 – 3d 2D5/2 electric quadrupole transition is reported. By setting the drive frequency to the “magic” frequency Ω 0, the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10−19 level. By precisely measuring the differential static scalar polarizability Δα 0, the uncertainty due to the blackbody radiation (BBR) shift (coefficient) is reduced to the 10−19 level. With the help of a second-order integrating servo algorithm, the uncertainty due to the servo error is reduced to the 10−18 level. The total fractional uncertainty of the 40Ca+ ion optical clock is then improved to 2.2× 10−17, whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations. The state preparation is introduced together with improvements in the pulse sequence, and furthermore, a better signal to noise ratio (SNR) and less dead time are achieved. The clock stability of a single clock is improved to 4.8 × 10 − 15 / τ ( in seconds ) .
Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.