The simulation of vibrational energy transport and quantum thermodynamics with trapped ions requires good methods for the estimation of temperatures. One valuable tool for this purpose is based on the fit of dark resonances in the fluorescence spectrum. However, this fit demands numerical simulations of the coupled electronic-motional dynamics which usually involve a trade-off between accuracy and speed. Here, we discuss several techniques with simplified dynamical equations for the simulation of the spectrum of a trapped ion that undergoes thermal motion, identifying the advantages and limitations of each method. We start with a three-level model to provide a better insight into the approximations involved, and then move on to tackle the experimentally relevant case of an eight-level calcium ion. We observe that mimicking the effect of thermal motion by means of additional dephasing is computationally very convenient, but can lead to significant errors in the estimation of the temperature. Nevertheless, this can be counteracted by a proper calibration, supporting the use of dark resonances as a practical thermometer.

DOI
10.1103/117l-94nf

Related papers

Fast thermometry for trapped ions using dark resonances

J. Roßnagel, Karl Nicolas Tolazzi, Ferdinand Schmidt‐Kaler +1 more

We experimentally demonstrate a method to determine the temperature of trapped ions which is suitable for monitoring fast thermalization processes. We show that observing and analyzing the lineshape of dark resonances in the fluorescence spectrum provides a temperature measurement which is accurate over a large dynamic range, applied to single ions and small ion crystals. Laser induced fluorescence is detected over a time of only , allowing for rapid determination of the ion temperature. In the measurement range of 10 −1 – mK we reach better than accuracy. Tuning the cooling laser to selected resonance features allows us to control the ion temperatures between mK and more than mK. Experimental work is supported by a solution of the eight-level optical Bloch equations when including the ions' classical motion. This technique paves the way for many experiments, including heat transport in ion strings, heat engines, non-equilibrium thermodynamics or thermometry of large ion crystals.

arXiv:1412.5014•New Journal of Physics•Apr 8, 2015•43 citations

Optical Bloch equations for simulating trapped-ion qubits

H. A. Janacek

This thesis describes work on numerical modelling of the 43Ca+ ion in a Paul trap using the optical Bloch equations. This is a challenging system to study, with many states involved in the internal dynamics. A major outcome is the development of a cooling scheme for the 146.09 gauss atomic clock transitions which makes use of a dark resonance. It is much more effective than methods that avoid coherent effects. The scheme is realised in experiment. Complicated fluorescence data is modelled very well, and predictions for the ion's motional temperature show good agreement with measured values. Data and fits for an ion that has been Doppler cooled below the Doppler limit are presented. I describe GLOBES, a set of routines that simulates an arbitrary ion in the presence of an arbitrary system of laser beams using the optical Bloch equations. Techniques used to efficiently calculate the steady state, analyse fluorescence scans and solve time-dependent problems for small and large times are discussed. A new routine SILVER IMPER that leapfrogs over the initial dynamics to model the approach to the steady state is introduced. Doppler cooling in 40Ca+ is analysed and two extensions made to the basic theory. The ‘excursion method’ of calculation takes account of the non-linear variation with velocity of the scattering rate. The ‘dynamic method’ allows for the fact that the ion may not be in equilibrium with the incident radiation during its oscillations, a necessity as the timescale of the external motion is of order the characteristic timescale of the internal motion for standard secular frequencies. This 'dynamic effect' is a general property of trapped ion systems and is also observed in a two-state system. A two-variable fluorescence scan taken from a four-laser, five-level system in 40Ca+ is analysed. Techniques to fit large data sets and automatically resolve resonant features are demonstrated. A general treatment of resonant behaviour in three, four and five level pump/probe systems is used to describe the data. This is verified by a second, tailor-made set of scans.

•Jan 1, 2015•2 citations

Dark resonance spectra of trapped ions under the influence of micromotion

Nicolás A. Nuñez Barreto, Muriel Bonetto, Marcelo Alejandro Luda +2 more

We study the influence of micromotion on the spectrum of trapped ions with a lambda-type level scheme, leading to dark resonances due to coherent population trapping. We work with calcium ions trapped in a ring-shaped Paul trap, in which one can compensate excess micromotion for only one ion of the crystal. We observe that micromotion affects the shapes of the dark resonances and causes the appearance of “echoes” separated by intervals given by the drive frequency. We present a theoretical model that provides good fits to the measurements and can be used to estimate the amplitude of the micromotion modulation of the atomic motion. We estimate an effective temperature of the ions from the spectra and observe clear micromotion heating as well as impaired cooling for sufficiently large excess micromotion.

arXiv:2402.01594•Frontiers in Quantum Science and Technology•Mar 27, 2024•1 citation

Sideband Thermometry of Ion Crystals

Ivan Vybornyi, Laura S. Dreissen, Dominik Kiesenhofer +7 more

Coulomb crystals of cold trapped ions are a leading platform for the realization of quantum processors and quantum simulations and, in quantum metrology, for the construction of optical atomic clocks and for fundamental tests of the standard model.For these applications, it is not only essential to cool the ion crystal in all its degrees of freedom down to the quantum ground state but also to be able to determine its temperature with a high accuracy.However, when a large ground-state cooled crystal is interrogated for thermometry, complex many-body interactions take place, making it challenging to accurately estimate the temperature with established techniques.In this work, we present a new thermometry method tailored for ion crystals.The method is applicable to all normal modes of motion and does not suffer from a computational bottleneck when applied to large ion crystals.We test the temperature estimate with two experiments, namely with a one-dimensional linear chain of four ions and a two-dimensional crystal of 19 ions and verify the results, where possible, using other methods.The results show that the new method is an accurate and efficient tool for thermometry of ion crystals.

arXiv:2306.07880•PRX Quantum•Dec 20, 2023•10 citations

Mode-resolved thermometry of a trapped ion with deep learning

Yi Tao, Ting Chen, Hongyang Wang +5 more

In a trapped-ion system, accurate thermometry of ions is crucial for precisely evaluating the system state and performing quantum operations. However, when the motional state of a single ion is far away from the ground state, the spatial dimensionality of the phonon state sharply increases. Then it is difficult to realize accurate and mode-resolved thermometry with existing methods. In this work, we apply deep learning to the thermometry of a trapped ion and propose an efficient and mode-resolved method for accurately estimating large mean phonon numbers. We have also conducted experimental verification based on a self-developed surface trap. The result has shown the significant accuracy and efficiency of the method for thermometry of a single ion with large mean phonon numbers. The mode-resolved feature of our method makes it better applied to the characterization of system parameters, such as evaluating cooling effectiveness and analyzing surface trap noise. Our trained neural network model can be easily extended to other experimental setups and parameter ranges without modification of the experimental setups.

arXiv:2402.19022•Physical Review A•Jun 25, 2024•5 citations

Towards Trapped-Ion Thermometry Using Cavity-Based EIT

Abhijit Kundu, Vijay Bhatt, Arijit Sharma

We present a technique for measuring ion temperature using cavity-based electromagnetically induced transparency (EIT) applicable for cavity QED systems. This method enables efficient extraction of the ion's phonon occupation number following sub-Doppler cooling close to the motional ground state. The proposed method requires operation in the resolved-sideband regime, where individual motional states can be selectively addressed for all relevant transitions either by selecting appropriate energy levels for the three-level system or by employing strong confinement with high secular frequencies ($\sim 10 MHz$). It relies on monitoring the cavity probe transmission while scanning the probe laser frequency to establish cavity-induced EIT using a control beam, thereby significantly simplifying the measurement procedure. We establish a theoretical model that demonstrates the influence of the thermal state of the trapped ion vis-à-vis the EIT linewidth measured. We show through numerical simulations how the cavity-induced EIT transmission may be used as a thermometry tool to deduce the ion temperature as well as its motional state in the sub-Doppler cooling regime, even for systems that are in the weak coupling regime.

quant-pharXiv:2602.12823•Feb 16, 2026•0 citations
The simulation of vibrational energy transport and quantum thermodynamics with trapped ions requires good methods for the estimation of temperatures. One valuable tool for this purpose is based on the fit of dark resonances in the fluorescence spectrum. However, this fit demands numerical simulations of the coupled electronic-motional dynamics which usually involve a trade-off between accuracy and speed. Here, we discuss several techniques with simplified dynamical equations for the simulation of the spectrum of a trapped ion that undergoes thermal motion, identifying the advantages and limitations of each method. We start with a three-level model to provide a better insight into the approximations involved, and then move on to tackle the experimentally relevant case of an eight-level calcium ion. We observe that mimicking the effect of thermal motion by means of additional dephasing is computationally very convenient, but can lead to significant errors in the estimation of the temperature. Nevertheless, this can be counteracted by a proper calibration, supporting the use of dark resonances as a practical thermometer.
We experimentally demonstrate a method to determine the temperature of trapped ions which is suitable for monitoring fast thermalization processes. We show that observing and analyzing the lineshape of dark resonances in the fluorescence spectrum provides a temperature measurement which is accurate over a large dynamic range, applied to single ions and small ion crystals. Laser induced fluorescence is detected over a time of only , allowing for rapid determination of the ion temperature. In the measurement range of 10 −1 – mK we reach better than accuracy. Tuning the cooling laser to selected resonance features allows us to control the ion temperatures between mK and more than mK. Experimental work is supported by a solution of the eight-level optical Bloch equations when including the ions' classical motion. This technique paves the way for many experiments, including heat transport in ion strings, heat engines, non-equilibrium thermodynamics or thermometry of large ion crystals.
This thesis describes work on numerical modelling of the 43Ca+ ion in a Paul trap using the optical Bloch equations. This is a challenging system to study, with many states involved in the internal dynamics. A major outcome is the development of a cooling scheme for the 146.09 gauss atomic clock transitions which makes use of a dark resonance. It is much more effective than methods that avoid coherent effects. The scheme is realised in experiment. Complicated fluorescence data is modelled very well, and predictions for the ion's motional temperature show good agreement with measured values. Data and fits for an ion that has been Doppler cooled below the Doppler limit are presented. I describe GLOBES, a set of routines that simulates an arbitrary ion in the presence of an arbitrary system of laser beams using the optical Bloch equations. Techniques used to efficiently calculate the steady state, analyse fluorescence scans and solve time-dependent problems for small and large times are discussed. A new routine SILVER IMPER that leapfrogs over the initial dynamics to model the approach to the steady state is introduced. Doppler cooling in 40Ca+ is analysed and two extensions made to the basic theory. The ‘excursion method’ of calculation takes account of the non-linear variation with velocity of the scattering rate. The ‘dynamic method’ allows for the fact that the ion may not be in equilibrium with the incident radiation during its oscillations, a necessity as the timescale of the external motion is of order the characteristic timescale of the internal motion for standard secular frequencies. This 'dynamic effect' is a general property of trapped ion systems and is also observed in a two-state system. A two-variable fluorescence scan taken from a four-laser, five-level system in 40Ca+ is analysed. Techniques to fit large data sets and automatically resolve resonant features are demonstrated. A general treatment of resonant behaviour in three, four and five level pump/probe systems is used to describe the data. This is verified by a second, tailor-made set of scans.
We study the influence of micromotion on the spectrum of trapped ions with a lambda-type level scheme, leading to dark resonances due to coherent population trapping. We work with calcium ions trapped in a ring-shaped Paul trap, in which one can compensate excess micromotion for only one ion of the crystal. We observe that micromotion affects the shapes of the dark resonances and causes the appearance of “echoes” separated by intervals given by the drive frequency. We present a theoretical model that provides good fits to the measurements and can be used to estimate the amplitude of the micromotion modulation of the atomic motion. We estimate an effective temperature of the ions from the spectra and observe clear micromotion heating as well as impaired cooling for sufficiently large excess micromotion.
Coulomb crystals of cold trapped ions are a leading platform for the realization of quantum processors and quantum simulations and, in quantum metrology, for the construction of optical atomic clocks and for fundamental tests of the standard model.For these applications, it is not only essential to cool the ion crystal in all its degrees of freedom down to the quantum ground state but also to be able to determine its temperature with a high accuracy.However, when a large ground-state cooled crystal is interrogated for thermometry, complex many-body interactions take place, making it challenging to accurately estimate the temperature with established techniques.In this work, we present a new thermometry method tailored for ion crystals.The method is applicable to all normal modes of motion and does not suffer from a computational bottleneck when applied to large ion crystals.We test the temperature estimate with two experiments, namely with a one-dimensional linear chain of four ions and a two-dimensional crystal of 19 ions and verify the results, where possible, using other methods.The results show that the new method is an accurate and efficient tool for thermometry of ion crystals.
In a trapped-ion system, accurate thermometry of ions is crucial for precisely evaluating the system state and performing quantum operations. However, when the motional state of a single ion is far away from the ground state, the spatial dimensionality of the phonon state sharply increases. Then it is difficult to realize accurate and mode-resolved thermometry with existing methods. In this work, we apply deep learning to the thermometry of a trapped ion and propose an efficient and mode-resolved method for accurately estimating large mean phonon numbers. We have also conducted experimental verification based on a self-developed surface trap. The result has shown the significant accuracy and efficiency of the method for thermometry of a single ion with large mean phonon numbers. The mode-resolved feature of our method makes it better applied to the characterization of system parameters, such as evaluating cooling effectiveness and analyzing surface trap noise. Our trained neural network model can be easily extended to other experimental setups and parameter ranges without modification of the experimental setups.
We present a technique for measuring ion temperature using cavity-based electromagnetically induced transparency (EIT) applicable for cavity QED systems. This method enables efficient extraction of the ion's phonon occupation number following sub-Doppler cooling close to the motional ground state. The proposed method requires operation in the resolved-sideband regime, where individual motional states can be selectively addressed for all relevant transitions either by selecting appropriate energy levels for the three-level system or by employing strong confinement with high secular frequencies (∼10MHz\sim 10 MHz∼10MHz). It relies on monitoring the cavity probe transmission while scanning the probe laser frequency to establish cavity-induced EIT using a control beam, thereby significantly simplifying the measurement procedure. We establish a theoretical model that demonstrates the influence of the thermal state of the trapped ion vis-à-vis the EIT linewidth measured. We show through numerical simulations how the cavity-induced EIT transmission may be used as a thermometry tool to deduce the ion temperature as well as its motional state in the sub-Doppler cooling regime, even for systems that are in the weak coupling regime.