Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2505.03865 · Physical Review Applied

Phase-modulation detection of a strontium-atom-interferometer gyroscope

Luke A. Kraft, Samuel A. Meek, Nathan Marliere, Akbar Jahangiri Jozani, Grant W. Biedermann

Published Jan 15, 2026• 1 citation
arXivHTMLPDF

Abstract

We demonstrate a strontium thermal beam atom interferometer gyroscope (AIG) on a rotation table using the $^{1\!}S_0$-$ ^{3\!}P_1$ intercombination line, and measure large rotation rates exceeding 6 rad/s. Our demonstration relies upon a transit-time-resonant (TTR), phase modulation technique for detecting the AIG phase which rejects signal background and variations in fringe amplitude.

DOI
10.1103/8xtw-781t

Related papers

Transit-time-resonant interferometry in a strontium thermal beam gyroscope

Luke A. Kraft

We demonstrate an atom interferometer gyroscope (AIG) using a strontium thermal beam. Our compact AIG consists of a stream of strontium atoms interacting with three laser pulses that split and recombine the matterwave flux to create a Mach-Zhender (MZ) interferometer sensitive to rotation. This system requires no cooling, no state preparation, and requires no microwave components. We also demonstrate a novel phase modulation technique for detecting the AIG response, which is especially useful for interferometers with a short time-of-flight. We will discuss our approach, latest results, and future plans. This thesis is organized in the following manner: Chapter 1 provides context to this work followed by relevant properties of ⁸⁸Sr. An overview of atom interferometry gyroscopes is covered in Chapter 2 followed by an explanation of phase modulation and its use in signal extraction in Chapter 3. Chapter 4 covers numerical investigation of the system parameter space. Next, the experimental apparatus is discussed in Chapter 5 followed by the results of our efforts in Chapter 6. Finally, Chapter 7 provides a summary of the most notable conclusions in this work.

•Jan 1, 2026•0 citations

Rotation sensing with a dual atom-interferometer Sagnac gyroscope

T. L. Gustavson, Arnaud Landragin, Mark A. Kasevich

We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.

Classical and Quantum Gravity•Jun 8, 2000•483 citations

Self-calibrated atom-interferometer gyroscope by modulating atomic velocities

Honghui Chen, Zhan-Wei Yao, Ze-Xi Lu +10 more

Atom-interferometer gyroscopes have attracted much attention for their long-term stability and extremely low drift. For such high-precision instruments, self-calibration to achieve an absolute rotation measurement is critical. In this work, we propose and demonstrate the self-calibration of an atom-interferometer gyroscope. This calibration is realized by using the detuning of the laser frequency to control the atomic velocity, thus modulating the scale factor of the gyroscope. The modulation determines the order and the initial phase of the interference stripe, thus eliminating the ambiguity caused by the periodicity of the interferometric signal. This self-calibration method is validated through a measurement of the Earth's rotation rate, and a relative uncertainty of 162 ppm is achieved. Long-term stable and self-calibrated atom-interferometer gyroscopes have important applications in the fields of fundamental physics, geophysics, and long-time navigation.

arXiv:2303.00239•Review of Scientific Instruments•May 1, 2024•5 citations

Continuous Dynamic Rotation Measurements Using a Compact Cold Atom Gyroscope

Zhan-Wei Yao, Si-Bin Lu, Runbing Li +4 more

We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase shift and contrast of the interference fringe are experimentally investigated. The results show that the contrast of the interference fringe is well held when the platform is rotated, and the phase shift of the interference fringe is linearly proportional to the rotation rate of the platform. The long-term stability, which is evaluated by the overlapped Allan deviation, is 8.5 × 10 −6 rad/s over the integrating time of 1000 s.

Chinese Physics Letters•Aug 1, 2016•16 citations

A Multi-Axis Atom Interferometer Gyroscope Based on a Grating Chip

Xiaojie Li, Zhixin Meng, Peiqiang Yan +2 more

We propose a new design of a multi-axis atom interferometer (AI) gyroscope based on a grating chip, which allows a single input laser beam for atomic trapping and coherent manipulation. Multiple AIs are formed by the input laser beam along with the other four diffractive beams generated by the grating chip. The rotation induced phase shifts from different input axes lead to different spatial interference fringes due to the modulation of the atomic velocity. With the point source interferometry (PSI) and the spatially resolved detection, multi-axis rotations may be measured by imaging the final atomic cloud after the interferometer sequence and decoding the information of spatial fringes from different input axes. Monte-Carlo based simulation are used for evaluating the proposed scheme and its application as a multi-axis gyroscope.

IEEE International Symposium on Inertial Sensors and Systems (INERTIAL)•Mar 1, 2020•0 citations

Precision Rotation Measurements with an Atom Interferometer Gyroscope

T. L. Gustavson, Philippe Bouyer, Mark A. Kasevich

We report the demonstration of a Sagnac-effect atom interferometer gyroscope which uses stimulated Raman transitions to coherently manipulate atomic wave packets. We have measured the Earth's rotation rate, and demonstrated a short-term sensitivity to rotations of $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}(\mathrm{rad}/\mathrm{s})/\sqrt{\mathrm{Hz}}$.

Physical Review Letters•Mar 17, 1997•794 citations
We demonstrate a strontium thermal beam atom interferometer gyroscope (AIG) on a rotation table using the 1 ⁣S0^{1\!}S_01S0​-3 ⁣P1 ^{3\!}P_13P1​ intercombination line, and measure large rotation rates exceeding 6 rad/s. Our demonstration relies upon a transit-time-resonant (TTR), phase modulation technique for detecting the AIG phase which rejects signal background and variations in fringe amplitude.
We demonstrate an atom interferometer gyroscope (AIG) using a strontium thermal beam. Our compact AIG consists of a stream of strontium atoms interacting with three laser pulses that split and recombine the matterwave flux to create a Mach-Zhender (MZ) interferometer sensitive to rotation. This system requires no cooling, no state preparation, and requires no microwave components. We also demonstrate a novel phase modulation technique for detecting the AIG response, which is especially useful for interferometers with a short time-of-flight. We will discuss our approach, latest results, and future plans. This thesis is organized in the following manner: Chapter 1 provides context to this work followed by relevant properties of ⁸⁸Sr. An overview of atom interferometry gyroscopes is covered in Chapter 2 followed by an explanation of phase modulation and its use in signal extraction in Chapter 3. Chapter 4 covers numerical investigation of the system parameter space. Next, the experimental apparatus is discussed in Chapter 5 followed by the results of our efforts in Chapter 6. Finally, Chapter 7 provides a summary of the most notable conclusions in this work.
We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.
Atom-interferometer gyroscopes have attracted much attention for their long-term stability and extremely low drift. For such high-precision instruments, self-calibration to achieve an absolute rotation measurement is critical. In this work, we propose and demonstrate the self-calibration of an atom-interferometer gyroscope. This calibration is realized by using the detuning of the laser frequency to control the atomic velocity, thus modulating the scale factor of the gyroscope. The modulation determines the order and the initial phase of the interference stripe, thus eliminating the ambiguity caused by the periodicity of the interferometric signal. This self-calibration method is validated through a measurement of the Earth's rotation rate, and a relative uncertainty of 162 ppm is achieved. Long-term stable and self-calibrated atom-interferometer gyroscopes have important applications in the fields of fundamental physics, geophysics, and long-time navigation.
We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase shift and contrast of the interference fringe are experimentally investigated. The results show that the contrast of the interference fringe is well held when the platform is rotated, and the phase shift of the interference fringe is linearly proportional to the rotation rate of the platform. The long-term stability, which is evaluated by the overlapped Allan deviation, is 8.5 × 10 −6 rad/s over the integrating time of 1000 s.
We propose a new design of a multi-axis atom interferometer (AI) gyroscope based on a grating chip, which allows a single input laser beam for atomic trapping and coherent manipulation. Multiple AIs are formed by the input laser beam along with the other four diffractive beams generated by the grating chip. The rotation induced phase shifts from different input axes lead to different spatial interference fringes due to the modulation of the atomic velocity. With the point source interferometry (PSI) and the spatially resolved detection, multi-axis rotations may be measured by imaging the final atomic cloud after the interferometer sequence and decoding the information of spatial fringes from different input axes. Monte-Carlo based simulation are used for evaluating the proposed scheme and its application as a multi-axis gyroscope.