Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2503.20003 · Physical Review A

Entanglement protocol to measure atomic parity violation at sub 0.1 % precision

Diana Prado Lopes Aude Craik

Published Jan 2, 2026• 3 citations
arXivHTMLPDF

Abstract

This paper proposes a scheme to measure atomic parity violation (APV) in barium ions at <0.1% precision. The scheme is based on using multi-ion entangled states to common-mode reject parity-conserving systematic shifts and selectively detect a parity-violating vector light shift. This measurement protocol eliminates the need to suppress a leading systematic by 11 orders of magnitude, as is required in the single-ion measurement scheme [N. Fortson, Phys. Rev. Lett. 70, 2383 (1993)]. Furthermore, the protocol can be combined with the use of integrated photonic waveguides in an architecture that is scalable to large ion numbers, with a proportional increase in measurement precision.

DOI
10.1103/cgsc-gqnq

Related papers

Towards entanglement-enhanced probing of atomic parity violation

Maxim Sirotin

Atomic parity violation (APV) provides a low-energy probe of the weak interaction between electrons and nuclei, complementary to collider tests of the Standard Model. Isotope-chain measurements are especially attractive because they test weak-charge scaling while reducing dependence on absolute atomic-structure theory. We review the APV mechanism, the state of the art in Cs and Yb, and recent trapped-ion, optical-lattice, and molecular proposals. Motivated by progress in coherent control of atoms, ions, and molecules, we ask a metrological question: given N probes distributed over an isotope chain, what quantum strategy optimally measures a deviation from Standard Model weak-charge scaling? The optimum is a particular form of a cross-isotope cat state protocol. We compare this protocol with the standard quantum limit, squeezed-array, same-isotope cat, and discuss extension to recently suggested decoherence-free subspace protocols. We show that entanglement can strongly accelerate statistical averaging, but the ultimate precision is set by APV-specific systematic floors which require careful studies.

quant-pharXiv:2605.27775•May 28, 2026•0 citations

Quantum metrology to probe atomic parity nonconservation

P. Mandal, Manas Mukherjee

An entangled state prepared in a decoherence-free subspace, together with a Ramsey-type measurement, can probe parity violation in heavy alkali-metal ions such as Ba${}^{+}$ or Ra${}^{+}$. Here we propose an experiment with Ba${}^{+}$ as an example to measure the small parity-violating effect in this system. It has been shown that a measurement on a maximally correlated system will reduce the uncertainty as compared to that on a single ion measurement, and also provides a feasible solution to measure the nuclear-spin-dependent part of the total parity-violating light shift in an ionic system.

arXiv:0901.1726•Physical Review A•Nov 23, 2010•12 citations

Atomic Parity Nonconservation Experiment

Pintu Mandal

Motivated by the challenges and limitation of existing experimental techniques, this work elaborates our recent proposal for the precision measurement of atomic parity nonconservation by quantum metrology with an entangled pair of trapped ions. Although the technique is fundamentally based on an existing proposal, it can potentially reach a figure of merit twice as high for an exceedingly tiny observable, yet to be measured in any ion trap experiment. The systematic of the technique have been shown to be better controlled as compared to other experiments. Since the goal of the experiment is to test the Standard Model of physics, the measured parity violating transitional dipole matrix element has to be compared with the theory of competitive precision. The choice of the element therefore plays an important role for the success of the experiment. Barium and radium ions have been compared from this perspective. The work presents the theoretical study on nuclear spin dependent atomic parity nonconservation and nuclear anapole moment in different isotopes of these ions and proposes specific transitions that are experimentally feasible.

•Mar 18, 2014•0 citations

Precision Measurement of Light Shifts in a Single Trapped Ba+ Ion

Jeff A. Sherman, Timo Koerber, Anna Markhotok +2 more

Using a single trapped barium ion we have developed an rf spectroscopy technique to measure the ratio of the off-resonant vector ac Stark effect (or light shift) in the $6{S}_{1/2}$ and $5{D}_{5/2}$ states to 0.1% precision. We find $R={\ensuremath{\Delta}}_{S}/{\ensuremath{\Delta}}_{D}=\ensuremath{-}11.494(13)$ at 514.531 nm where ${\ensuremath{\Delta}}_{S,D}$ are the light shifts of the $m=\ifmmode\pm\else\textpm\fi{}1/2$ splittings due to circularly polarized light. Comparison of this result with an ab initio calculation of $R$ would yield a new test of atomic theory and improve the understanding of atomic structure needed to interpret a proposed atomic parity violation experiment. By appropriately choosing an off-resonant light shift wavelength one can emphasize the contribution of one or a few dipole matrix elements and precisely determine their values.

arXiv:physics/0502113•Physical Review Letters•Jun 21, 2005•60 citations

Precision frequency measurements with entangled ions

Christian F. Roos, Michael Chwalla, Mark Riebe +6 more

Summary form only given. The use of entangled states can provide an increased sensitivity in quantum-limited spectroscopic measurements, leading to an uncertainty that is inversely proportional to the number of particles instead of the usual square-law dependence. In this contribution, we show that spectroscopy with maximally entangled states of atoms also offers significant advantages over experiments done with single atoms. As a first example, we demonstrate that entanglement can be used to effectively eliminate first-order Zeeman shifts in spectroscopy with 40Ca+ even though there are no m=0 -> m=0 transitions. Secondly, we discuss how maximally correlated states of two 40Ca+ could be used for measuring tiny frequency shifts of the S1/2 - D5/2 transition arising from second-order Zeeman shifts and electric quadrupole shifts due to the trapping potential.

European Frequency and Time Forum•Jan 1, 2004•0 citations

Atom-Atom Entanglement by Single-Photon Detection

L. Slodička, Gabriel Hetet, N. Röck +3 more

A scheme for entangling distant atoms is realized, as proposed in the seminal paper by [C. Cabrillo et al., Phys. Rev. A 59, 1025 (1999)]. The protocol is based on quantum interference and detection of a single photon scattered from two effectively one meter distant laser cooled and trapped atomic ions. The detection of a single photon heralds entanglement of two internal states of the trapped ions with high rate and with a fidelity limited mostly by atomic motion. Control of the entangled state phase is demonstrated by changing the path length of the single-photon interferometer.

arXiv:1207.5468•Physical Review Letters•Feb 21, 2013•103 citations
This paper proposes a scheme to measure atomic parity violation (APV) in barium ions at <0.1% precision. The scheme is based on using multi-ion entangled states to common-mode reject parity-conserving systematic shifts and selectively detect a parity-violating vector light shift. This measurement protocol eliminates the need to suppress a leading systematic by 11 orders of magnitude, as is required in the single-ion measurement scheme [N. Fortson, Phys. Rev. Lett. 70, 2383 (1993)]. Furthermore, the protocol can be combined with the use of integrated photonic waveguides in an architecture that is scalable to large ion numbers, with a proportional increase in measurement precision.
Atomic parity violation (APV) provides a low-energy probe of the weak interaction between electrons and nuclei, complementary to collider tests of the Standard Model. Isotope-chain measurements are especially attractive because they test weak-charge scaling while reducing dependence on absolute atomic-structure theory. We review the APV mechanism, the state of the art in Cs and Yb, and recent trapped-ion, optical-lattice, and molecular proposals. Motivated by progress in coherent control of atoms, ions, and molecules, we ask a metrological question: given N probes distributed over an isotope chain, what quantum strategy optimally measures a deviation from Standard Model weak-charge scaling? The optimum is a particular form of a cross-isotope cat state protocol. We compare this protocol with the standard quantum limit, squeezed-array, same-isotope cat, and discuss extension to recently suggested decoherence-free subspace protocols. We show that entanglement can strongly accelerate statistical averaging, but the ultimate precision is set by APV-specific systematic floors which require careful studies.
An entangled state prepared in a decoherence-free subspace, together with a Ramsey-type measurement, can probe parity violation in heavy alkali-metal ions such as Ba+{}^{+}+ or Ra+{}^{+}+. Here we propose an experiment with Ba+{}^{+}+ as an example to measure the small parity-violating effect in this system. It has been shown that a measurement on a maximally correlated system will reduce the uncertainty as compared to that on a single ion measurement, and also provides a feasible solution to measure the nuclear-spin-dependent part of the total parity-violating light shift in an ionic system.
Motivated by the challenges and limitation of existing experimental techniques, this work elaborates our recent proposal for the precision measurement of atomic parity nonconservation by quantum metrology with an entangled pair of trapped ions. Although the technique is fundamentally based on an existing proposal, it can potentially reach a figure of merit twice as high for an exceedingly tiny observable, yet to be measured in any ion trap experiment. The systematic of the technique have been shown to be better controlled as compared to other experiments. Since the goal of the experiment is to test the Standard Model of physics, the measured parity violating transitional dipole matrix element has to be compared with the theory of competitive precision. The choice of the element therefore plays an important role for the success of the experiment. Barium and radium ions have been compared from this perspective. The work presents the theoretical study on nuclear spin dependent atomic parity nonconservation and nuclear anapole moment in different isotopes of these ions and proposes specific transitions that are experimentally feasible.
Using a single trapped barium ion we have developed an rf spectroscopy technique to measure the ratio of the off-resonant vector ac Stark effect (or light shift) in the 6S1/26{S}_{1/2}6S1/2​ and 5D5/25{D}_{5/2}5D5/2​ states to 0.1% precision. We find $R={\ensuremath{\Delta}}_{S}/{\ensuremath{\Delta}}_{D}=\ensuremath{-}11.494(13)$ at 514.531 nm where ${\ensuremath{\Delta}}_{S,D}$ are the light shifts of the $m=\ifmmode\pm\else\textpm\fi{}1/2$ splittings due to circularly polarized light. Comparison of this result with an ab initio calculation of RRR would yield a new test of atomic theory and improve the understanding of atomic structure needed to interpret a proposed atomic parity violation experiment. By appropriately choosing an off-resonant light shift wavelength one can emphasize the contribution of one or a few dipole matrix elements and precisely determine their values.
Summary form only given. The use of entangled states can provide an increased sensitivity in quantum-limited spectroscopic measurements, leading to an uncertainty that is inversely proportional to the number of particles instead of the usual square-law dependence. In this contribution, we show that spectroscopy with maximally entangled states of atoms also offers significant advantages over experiments done with single atoms. As a first example, we demonstrate that entanglement can be used to effectively eliminate first-order Zeeman shifts in spectroscopy with 40Ca+ even though there are no m=0 -> m=0 transitions. Secondly, we discuss how maximally correlated states of two 40Ca+ could be used for measuring tiny frequency shifts of the S1/2 - D5/2 transition arising from second-order Zeeman shifts and electric quadrupole shifts due to the trapping potential.
A scheme for entangling distant atoms is realized, as proposed in the seminal paper by [C. Cabrillo et al., Phys. Rev. A 59, 1025 (1999)]. The protocol is based on quantum interference and detection of a single photon scattered from two effectively one meter distant laser cooled and trapped atomic ions. The detection of a single photon heralds entanglement of two internal states of the trapped ions with high rate and with a fidelity limited mostly by atomic motion. Control of the entangled state phase is demonstrated by changing the path length of the single-photon interferometer.