Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2503.07859 · Communications Physics

Unifying attoclock and Larmor measurements through position-resolved weak values

Pablo M. Maier, Serguei Patchkovskii, Misha Ivanov, Olga V. Smirnova

Published Apr 17, 2026• 2 citations
arXivHTMLPDF

Abstract

Abstract The measurement of tunneling times in strong-field ionization has been the topic of much controversy in recent years, with the attoclock and Larmor clock being two of the main contenders for correctly reproducing these times. While the non-zero Larmor tunneling time has been unambiguously detected, the tunneling time measured by the attoclock appears to vanish in tunnel ionization of a hydrogen atom. By expressing the attoclock as the weak value of temporal delay, we extend its meaning beyond the traditional setup and connect it to the weak-value interpretation of the Larmor clock. Our approach allows us to derive the position-resolved attoclock tunneling time. We show how this time, while non-zero at the tunnel exit, vanishes at the detector, far away from the atom. Formally, this means that the attoclock does not measure the “local” Larmor time, but instead a “non-local” time closely related to the phase time.

DOI
10.1038/s42005-026-02615-6

Related papers

Tunneling Time and Weak Measurement in Strong Field Ionization

Tomáš Zimmermann, Siddhartha Mishra, Brent Doran +2 more

Tunneling delays represent a hotly debated topic, with many conflicting definitions and little consensus on when and if such definitions accurately describe the physical observables. Here, we relate these different definitions to distinct experimental observables in strong field ionization, finding that two definitions, Larmor time and Bohmian time, are compatible with the attoclock observable and the resonance lifetime of a bound state, respectively. Both of these definitions are closely connected to the theory of weak measurement, with Larmor time being the weak measurement value of tunneling time and Bohmian trajectory corresponding to the average particle trajectory, which has been recently reconstructed using weak measurement in a two-slit experiment [S. Kocsis, B. Braverman, S. Ravets, M. J. Stevens, R. P. Mirin, L. K. Shalm, and A. M. Steinberg, Science 332, 1170 (2011)]. We demonstrate a big discrepancy in strong field ionization between the Bohmian and weak measurement values of tunneling time, and we suggest this arises because the tunneling time is calculated for a small probability postselected ensemble of electrons. Our results have important implications for the interpretation of experiments in attosecond science, suggesting that tunneling is unlikely to be an instantaneous process.

Physical Review Letters•Jun 10, 2016•112 citations

Universal behavior of tunneling time and barrier time-delay decoupling in attoclock measurements

Ossama Kullie

Abstract The measurement of the tunneling time-delay is hotly debated and remains controversial. In previous works, we showed that a model that accurately describes the time-delay measured by the attoclock experiment in adiabatic and nonadiabatic field calibrations. In the present work, we show that the tunneling time reveals a universal behavior with disentangled contributions. Even more remarkable is that the barrier tunneling time-delay can be convincingly defined and determined from the difference between the time-delay of adiabatic and nonadiabatic tunnel-ionization, which also show good agreement with experimental results. Furthermore, we illustrate that in the weak measurement limit, the barrier time-delay corresponds to the Larmor-clock time and the interaction time within the barrier.

arXiv:2402.14431•Journal of Physics Communications•Jan 1, 2025•0 citations

Universal behavior of tunneling time and barrier time-delay decoupling in attoclock measurements

Ossama Kullie

The measurement of the tunneling time-delay is hotly debated and remains controversial. In previous works, we showed that a model that accurately describes the time-delay measured by the attoclock experiment in adiabatic and nonadiabatic field calibrations. In the present work, we show that the tunneling time reveals a universal behavior with disentangled contributions. Even more remarkable is that the barrier tunneling time-delay can be convincingly defined and determined from the difference between the time-delay of adiabatic and nonadiabatic tunnel-ionization, which also show good agreement with experimental results. Furthermore, we illustrate that in the weak measurement limit, the barrier time-delay corresponds to the Larmor-clock time and the interaction time within the barrier.

•Feb 11, 2025•0 citations

Decoding electron tunnelling delay time by embracing wave-particle duality

Chuncheng Wang, Xiaokai Li, Xiwang Liu +7 more

Tunnelling lies at the heart of quantum mechanics and is a fundamental process in attosecond science, molecular biology, and quantum devices. Whether tunnelling takes time and how a microscopic particle transits through a barrier have been debated since the early days of quantum mechanics. The time required for an electron to tunnel through an atomic potential barrier has been measured with attosecond angular streaking (attoclock), and a recent work on the hydrogen atom claimed that electron tunnelling is instantaneous. However, the time required for Rb atoms to tunnel through an optical potential barrier has been measured to be on the order of milliseconds with a recent Larmor clock measurement. The essence of electron and atom tunnelling is identical, but the reason for the contradictory conclusions remains unknown. Here, we demonstrate that the sub-barrier potential interaction is the root of the nonzero tunnelling delay time. We reveal that the wave-particle duality of a tunnelling electron must be fully taken into account when decoding the tunnelling delay time from the attoclock measurements. Based on energy-resolved attoclock measurements, we show that the tunnelling delay time of an electron ranges from 24 to 58 attoseconds, and the counterintuitive result that an electron with a lower energy may spend less time in the barrier is consistent with the velocity-dependent tunnelling time of atoms in Larmor clock measurements. Our results unify the tunnelling time of microscopic particles by highlighting the classically forbidden sub-barrier potential interactions of matter waves.

arXiv:2104.06144•Apr 13, 2021•3 citations

Tunneling Time, Exit Time and Exit Momentum in Strong Field Tunnel Ionization

Nicolas Teeny

Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schr{\\"o}dinger equation in one and two dimensions and use \\textit{ab initio} quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.

•Jan 1, 2016•1 citation

Distribution of ionization and tunneling times in a model of strong field ionization

Jose Tadeu Lunardi, Luiz A. Manzoni

Abstract We consider a simple model for strong field ionization and use the Salecker-Wigner-Peres clock to obtain a distribution of (real) times associated with this phenomenon. By coupling the Salecker-Wigner-Peres clock to the particle in different regions, we are able to distinguish between the ionization (exit) time, the tunneling time and the time the particle spends in the well before entering the barrier (the well time). We show that the distribution of ionization/exit times, which are the times usually measured in attoclock experiments, may differ significantly from the distribution of tunneling times, suggesting that the ionization times cannot be generally interpreted as tunneling times.

Journal of Physics Conference Series•Nov 1, 2019•1 citation
Abstract The measurement of tunneling times in strong-field ionization has been the topic of much controversy in recent years, with the attoclock and Larmor clock being two of the main contenders for correctly reproducing these times. While the non-zero Larmor tunneling time has been unambiguously detected, the tunneling time measured by the attoclock appears to vanish in tunnel ionization of a hydrogen atom. By expressing the attoclock as the weak value of temporal delay, we extend its meaning beyond the traditional setup and connect it to the weak-value interpretation of the Larmor clock. Our approach allows us to derive the position-resolved attoclock tunneling time. We show how this time, while non-zero at the tunnel exit, vanishes at the detector, far away from the atom. Formally, this means that the attoclock does not measure the “local” Larmor time, but instead a “non-local” time closely related to the phase time.
Tunneling delays represent a hotly debated topic, with many conflicting definitions and little consensus on when and if such definitions accurately describe the physical observables. Here, we relate these different definitions to distinct experimental observables in strong field ionization, finding that two definitions, Larmor time and Bohmian time, are compatible with the attoclock observable and the resonance lifetime of a bound state, respectively. Both of these definitions are closely connected to the theory of weak measurement, with Larmor time being the weak measurement value of tunneling time and Bohmian trajectory corresponding to the average particle trajectory, which has been recently reconstructed using weak measurement in a two-slit experiment [S. Kocsis, B. Braverman, S. Ravets, M. J. Stevens, R. P. Mirin, L. K. Shalm, and A. M. Steinberg, Science 332, 1170 (2011)]. We demonstrate a big discrepancy in strong field ionization between the Bohmian and weak measurement values of tunneling time, and we suggest this arises because the tunneling time is calculated for a small probability postselected ensemble of electrons. Our results have important implications for the interpretation of experiments in attosecond science, suggesting that tunneling is unlikely to be an instantaneous process.
Abstract The measurement of the tunneling time-delay is hotly debated and remains controversial. In previous works, we showed that a model that accurately describes the time-delay measured by the attoclock experiment in adiabatic and nonadiabatic field calibrations. In the present work, we show that the tunneling time reveals a universal behavior with disentangled contributions. Even more remarkable is that the barrier tunneling time-delay can be convincingly defined and determined from the difference between the time-delay of adiabatic and nonadiabatic tunnel-ionization, which also show good agreement with experimental results. Furthermore, we illustrate that in the weak measurement limit, the barrier time-delay corresponds to the Larmor-clock time and the interaction time within the barrier.
The measurement of the tunneling time-delay is hotly debated and remains controversial. In previous works, we showed that a model that accurately describes the time-delay measured by the attoclock experiment in adiabatic and nonadiabatic field calibrations. In the present work, we show that the tunneling time reveals a universal behavior with disentangled contributions. Even more remarkable is that the barrier tunneling time-delay can be convincingly defined and determined from the difference between the time-delay of adiabatic and nonadiabatic tunnel-ionization, which also show good agreement with experimental results. Furthermore, we illustrate that in the weak measurement limit, the barrier time-delay corresponds to the Larmor-clock time and the interaction time within the barrier.
Tunnelling lies at the heart of quantum mechanics and is a fundamental process in attosecond science, molecular biology, and quantum devices. Whether tunnelling takes time and how a microscopic particle transits through a barrier have been debated since the early days of quantum mechanics. The time required for an electron to tunnel through an atomic potential barrier has been measured with attosecond angular streaking (attoclock), and a recent work on the hydrogen atom claimed that electron tunnelling is instantaneous. However, the time required for Rb atoms to tunnel through an optical potential barrier has been measured to be on the order of milliseconds with a recent Larmor clock measurement. The essence of electron and atom tunnelling is identical, but the reason for the contradictory conclusions remains unknown. Here, we demonstrate that the sub-barrier potential interaction is the root of the nonzero tunnelling delay time. We reveal that the wave-particle duality of a tunnelling electron must be fully taken into account when decoding the tunnelling delay time from the attoclock measurements. Based on energy-resolved attoclock measurements, we show that the tunnelling delay time of an electron ranges from 24 to 58 attoseconds, and the counterintuitive result that an electron with a lower energy may spend less time in the barrier is consistent with the velocity-dependent tunnelling time of atoms in Larmor clock measurements. Our results unify the tunnelling time of microscopic particles by highlighting the classically forbidden sub-barrier potential interactions of matter waves.
Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schr{\\"o}dinger equation in one and two dimensions and use \\textit{ab initio} quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.
Abstract We consider a simple model for strong field ionization and use the Salecker-Wigner-Peres clock to obtain a distribution of (real) times associated with this phenomenon. By coupling the Salecker-Wigner-Peres clock to the particle in different regions, we are able to distinguish between the ionization (exit) time, the tunneling time and the time the particle spends in the well before entering the barrier (the well time). We show that the distribution of ionization/exit times, which are the times usually measured in attoclock experiments, may differ significantly from the distribution of tunneling times, suggesting that the ionization times cannot be generally interpreted as tunneling times.