Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2502.05168 · Physical Review Research

Impulse measurements enhanced with squeezed readout light

Tsai-Chen Lee, Jacob L. Beckey, Giacomo Marocco, Daniel Carney

Published May 16, 2025• 8 citations
arXivHTMLPDF

Abstract

We quantify how squeezed light can reduce quantum measurement noise to levels below the standard quantum limit in impulse measurements with mechanical detectors. The broadband nature of the signal implies that frequency-dependent squeezing performs better than frequency-independent squeezing. We calculate the optimal scaling of the impulse sensitivity with the squeezing strength and quantify degradations due to photodetection losses. Even for lossless measurement, we find there exists a fundamental limit to the benefit of squeezing that depends only on the system's mechanical properties.

DOI
10.1103/kcm9-bqs8

Related papers

Combining quantum noise reduction resources: A practical approach

Sohitri Ghosh, Matthew A. Feldman, Seongjin Hong +4 more

Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. We demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.

arXiv:2211.14460•Physical Review A•Jun 26, 2025•6 citations

Three-dimensional squeezing of optically levitated nanospheres

Giacomo Marocco, David C. Moore, Daniel Carney

We propose a protocol to measure impulses beyond the standard quantum limit. The protocol reduces noise in all three spatial dimensions and consists of squeezing a mechanical system's state via a series of jumps in the frequency of the harmonic potential. We quantify how decoherence in a realistic system of an optically levitated, dielectric nanoparticle limits the ultimate sensitivity. We predict that $\sim$10 dB of squeezing is achievable with current technology, enabling quantum-enhanced detection of weak impulses.

quant-pharXiv:2601.22283•Physical Review A•Feb 2, 2026•6 citations

Fundamental limits to observations of squeezing via balanced homodyne detection

Samuel L. Braunstein, David D. Crouch

A photodetector's electronic bandwidth is the frequency range over which beats between different frequencies in the input can be observed in the output. The output of a balanced homodyne detector, the prototypical device for detecting squeezed light, consists of beats between a signal to be measured and a local oscillator. Beats between the signal and quantum local-oscillator fluctuations lead to noise that degrades the observed squeezing. Through wide-band calculations, we show that this noise contains contributions from the entire signal bandwidth, even when this bandwidth is orders of magnitude larger than the detector's electronic bandwidth. This allows us to place an upper limit on the total power that can enter the detector's signal port (both signal and extraneous light) within the detector's optical bandwidth in order for a given level of squeezing to be observable.

Physical Review A•Jan 1, 1991•10 citations

Fundamental sensitivity limit of lossy cavity-enhanced interferometers with external and internal squeezing

M. Korobko, Jan Südbeck, S. Steinlechner +1 more

Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in implementing cavities and quantum squeezed light for enhancing sensitivity to signals from black hole or neutron star mergers. However, the sensitivity to weak forces is limited by the available energy and the optical decoherence in the system. Here, we derive the fundamental sensitivity limit of cavity- and squeezed-light-enhanced interferometers with optical loss. This limit is attained by the optimal use of an additional internal squeeze operation, which allows the mitigation of readout loss. We demonstrate the application of internal squeezing to various scenarios and confirm that it indeed allows one to reach the best sensitivity in cavity- and squeezed-light-enhanced linear force sensors. Our work establishes the groundwork for the future development of optimal sensors in real-world scenarios where, up until now, the application of squeezed light was curtailed by various sources of decoherence.

arXiv:2307.09130•Physical Review A•Dec 6, 2023•7 citations

Broadband Quantum Enhancement of the LIGO Detectors with Frequency-Dependent Squeezing

D. Ganapathy, W. Jia, M. Nakano +97 more

Quantum noise imposes a fundamental limitation on the sensitivity of interferometric gravitationalwave detectors like LIGO, manifesting as shot noise and quantum radiation pressure noise.Here, we present the first realization of frequency-dependent squeezing in full-scale gravitational-wave detectors, resulting in the reduction of both shot noise and quantum radiation pressure noise, with broadband detector enhancement from tens of hertz to several kilohertz.In the LIGO Hanford detector, squeezing reduced the detector noise amplitude by a factor of 1.6 (4.0 dB) near 1 kHz; in the Livingston detector, the noise reduction was a factor of 1.9 (5.8 dB).These improvements directly impact LIGO's scientific output for high-frequency sources (e.g., binary neutron star postmerger physics).The improved lowfrequency sensitivity, which boosted the detector range by 15%-18% with respect to no squeezing, corresponds to an increase in the astrophysical detection rate of up to 65%.Frequency-dependent squeezing was enabled by the addition of a 300-meter-long filter cavity to each detector as part of the LIGO Aþ upgrade.

Physical Review X•Oct 30, 2023•189 citations

Squeezing-enhanced heterodyne detection of 10 Hz atto-Watt optical signals

Boya Xie, Sheng Feng

A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.

Optics Letters•Dec 12, 2018•23 citations
We quantify how squeezed light can reduce quantum measurement noise to levels below the standard quantum limit in impulse measurements with mechanical detectors. The broadband nature of the signal implies that frequency-dependent squeezing performs better than frequency-independent squeezing. We calculate the optimal scaling of the impulse sensitivity with the squeezing strength and quantify degradations due to photodetection losses. Even for lossless measurement, we find there exists a fundamental limit to the benefit of squeezing that depends only on the system's mechanical properties.
Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. We demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.
We propose a protocol to measure impulses beyond the standard quantum limit. The protocol reduces noise in all three spatial dimensions and consists of squeezing a mechanical system's state via a series of jumps in the frequency of the harmonic potential. We quantify how decoherence in a realistic system of an optically levitated, dielectric nanoparticle limits the ultimate sensitivity. We predict that $\sim$10 dB of squeezing is achievable with current technology, enabling quantum-enhanced detection of weak impulses.
A photodetector's electronic bandwidth is the frequency range over which beats between different frequencies in the input can be observed in the output. The output of a balanced homodyne detector, the prototypical device for detecting squeezed light, consists of beats between a signal to be measured and a local oscillator. Beats between the signal and quantum local-oscillator fluctuations lead to noise that degrades the observed squeezing. Through wide-band calculations, we show that this noise contains contributions from the entire signal bandwidth, even when this bandwidth is orders of magnitude larger than the detector's electronic bandwidth. This allows us to place an upper limit on the total power that can enter the detector's signal port (both signal and extraneous light) within the detector's optical bandwidth in order for a given level of squeezing to be observable.
Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in implementing cavities and quantum squeezed light for enhancing sensitivity to signals from black hole or neutron star mergers. However, the sensitivity to weak forces is limited by the available energy and the optical decoherence in the system. Here, we derive the fundamental sensitivity limit of cavity- and squeezed-light-enhanced interferometers with optical loss. This limit is attained by the optimal use of an additional internal squeeze operation, which allows the mitigation of readout loss. We demonstrate the application of internal squeezing to various scenarios and confirm that it indeed allows one to reach the best sensitivity in cavity- and squeezed-light-enhanced linear force sensors. Our work establishes the groundwork for the future development of optimal sensors in real-world scenarios where, up until now, the application of squeezed light was curtailed by various sources of decoherence.
Quantum noise imposes a fundamental limitation on the sensitivity of interferometric gravitationalwave detectors like LIGO, manifesting as shot noise and quantum radiation pressure noise.Here, we present the first realization of frequency-dependent squeezing in full-scale gravitational-wave detectors, resulting in the reduction of both shot noise and quantum radiation pressure noise, with broadband detector enhancement from tens of hertz to several kilohertz.In the LIGO Hanford detector, squeezing reduced the detector noise amplitude by a factor of 1.6 (4.0 dB) near 1 kHz; in the Livingston detector, the noise reduction was a factor of 1.9 (5.8 dB).These improvements directly impact LIGO's scientific output for high-frequency sources (e.g., binary neutron star postmerger physics).The improved lowfrequency sensitivity, which boosted the detector range by 15%-18% with respect to no squeezing, corresponds to an increase in the astrophysical detection rate of up to 65%.Frequency-dependent squeezing was enabled by the addition of a 300-meter-long filter cavity to each detector as part of the LIGO Aþ upgrade.
A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.