Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2501.14049 · Journal of the Optical Society of America A

Grover–Sagnac interferometer

Christopher R. Schwarze, Anthony D. Manni, David S. Simon, Abdoulaye Ndao, Alexander V. Sergienko

Published Jan 7, 2025• 5 citations
arXivHTMLPDF

Abstract

We demonstrate a nontraditional design of the Sagnac interferometer by replacing the commonly used beam splitter with a linear-optical Grover multiport. This substitution creates a pole at the origin of the device parameter space, with an associated resonance in the output intensity. The structure of this resonance is dictated only by the nonreciprocal portion of the phase acquired in the Sagnac loop. This property directly results from adopting the more symmetric and higher-dimensional central scattering coin, and it allows for a different approach to registering and detecting the nonreciprocal Sagnac phase. This parameter may be extracted from the width of a peak or dip in the interferogram, instead of tracing small changes in power as in traditional Sagnac interferometry. We discuss how losses affect the system and potential metrological applications.

DOI
10.1364/josaa.549928

Related papers

Interferometry and higher-dimensional phase measurements using directionally unbiased linear optics

David S. Simon, Christopher R. Schwarze, Alexander V. Sergienko

Grover multiports are higher-dimensional generalizations of beam splitters, in which input to any one of the four ports has equal probability of exiting at any of the same four ports, including the input port. In this paper, we demonstrate that interferometers built from such multiports have novel features. For example, when combined with two-photon input and coincidence measurements, it is shown that such interferometers have capabilities beyond those of standard beam-splitter-based interferometers, such as easily controlled interpolation between Hong-Ou-Mandel (HOM) and anti-HOM behavior. Further, it is shown that the Grover-based analog of the Mach-Zehnder interferometer can make three separate phase measurements simultaneously. By arranging the transmission lines between the two multiports to lie in different planes, the same interferometer acts as a higher-dimensional Sagnac interferometer, allowing rotation rates about three different axes to be measured with a single device.

arXiv:2209.09414•Physical Review A•Sep 15, 2022•11 citations

Experimental demonstration of a Grover-Michelson interferometer

Christopher R. Schwarze, David S. Simon, Anthony D. Manni +2 more

We present a low-resource and robust optical implementation of the four-dimensional Grover coin, a four-port linear-optical scatterer that augments the low dimensionality of a regular beam-splitter. While prior realizations of the Grover coin required a potentially unstable ring cavity to be formed, this version of the scatterer does not exhibit any internal interference. When this Grover coin is placed in another system, it can be used for interferometry with a higher-dimensional set of optical field modes. In this case, we formed a Grover-Michelson interferometer, which results when the traditional beam-splitter of a Michelson interferometer is replaced with a four-port Grover coin. This replacement has been shown to remove a phase parameter redundancy in the original Michelson system, now allowing continuous tuning of the shape and slope of the interference pattern. We observed an intensity interferogram with 97% visibility and a phase sensitivity more than an order of magnitude larger than a regular Michelson interferometer. Because this device is readily formed with nearly the same number of optomechanical resources as a Michelson interferometer but can outperform it drastically in phase delay evaluation, it has a great potential to improve many interferometric sensing and control systems.

arXiv:2409.04303•Optics Express•Aug 28, 2024•11 citations

Experimental demonstration of enhanced-sensitivity Grover-Michelson interferometer for quantum sensing

Christopher R. Schwarze, David S. Simon, Anthony D. Manni +2 more

We construct and characterize a Grover coin with tabletop optics. This directionally unbiased higher-dimensional four-port scatterer replaces a standard beam-splitter in the Michelson interferometer, resulting in a sharper phase response without reducing visibility.

Conference on Lasers and Electro-Optics•Jan 1, 2025•0 citations

Enhanced-sensitivity interferometry with phase-sensitive unbiased multiports

Christopher R. Schwarze, David S. Simon, Alexander V. Sergienko

Here we introduce interferometric devices by combining optical feedback (cavities) with unbiased multiports, which, unlike traditional beam dividers, allow light to reflect back out of the port from which it originated. By replacing the traditional, directionally biased beam-splitter in a Michelson interferometer with an unbiased multiport, the functional dependence of the scattering amplitudes changes. As a result, the derivative of transmittance with respect to an external phase perturbation can be made substantially large. This significantly enhances the resolution of phase measurement and allows the phase response curves to be altered in real time by tuning an externally controllable phase shift.

arXiv:2306.00098•Physical Review A•May 25, 2023•15 citations

Nonlinear Sagnac interferometer based on the four-wave mixing process

Jun Xin, Jinming Liu, Jietai Jing

A new nonlinear Sagnac interferometer (NSI) is proposed by replacing the beam-splitter in the traditional Sagnac interferometer (TSI) with a four-wave mixing process. Such a NSI has better angular velocity sensitivity than the one of the TSI. The standard quantum limit can be beaten and the Heisenberg Limit can even be reached for the ideal case by the NSI. We study the effect of the losses on the angular velocity sensitivity of the NSI and find that the optimal angular velocity, where the best angular velocity sensitivity can be obtained, of the NSI may be dependent on the losses inside the interferometer. Such a NSI has its advantages compared with the TSI and may find its potential applications in quantum metrology.

Optics Express•Jan 18, 2017•14 citations

Single-photon description of the lossless optical Y coupler

Christopher R. Schwarze, Anthony D. Manni, David S. Simon +1 more

Using symmetry considerations, we derive a unitary scattering matrix for a three-port optical Y coupler or Y branch. The result is shown to be unique up to external phase shifts. Unlike traditional passive linear-optical one-way splitters, coupling light into the conventional output ports of the Y coupler results in strong coherent back-reflections, making the device a hybrid between feed-forward devices like the beam splitter, which do not reverse the direction of light, and a recently considered class of directionally unbiased multiport scatterers (with dimension greater than two), which do. While the device could immediately find use as a novel scattering vertex for the implementation of quantum walks, we also design a few simple but nonetheless useful optical systems that can be constructed by taking advantage of the symmetry of the scattering process. This includes an interference-free, resource-efficient implementation of the Grover four-port and a higher-dimensional Fabry-Perot interferometer with tunable finesse. Symmetry-breaking generalizations are also considered.

arXiv:2408.15304•Physical Review A•Aug 27, 2024•6 citations
We demonstrate a nontraditional design of the Sagnac interferometer by replacing the commonly used beam splitter with a linear-optical Grover multiport. This substitution creates a pole at the origin of the device parameter space, with an associated resonance in the output intensity. The structure of this resonance is dictated only by the nonreciprocal portion of the phase acquired in the Sagnac loop. This property directly results from adopting the more symmetric and higher-dimensional central scattering coin, and it allows for a different approach to registering and detecting the nonreciprocal Sagnac phase. This parameter may be extracted from the width of a peak or dip in the interferogram, instead of tracing small changes in power as in traditional Sagnac interferometry. We discuss how losses affect the system and potential metrological applications.
Grover multiports are higher-dimensional generalizations of beam splitters, in which input to any one of the four ports has equal probability of exiting at any of the same four ports, including the input port. In this paper, we demonstrate that interferometers built from such multiports have novel features. For example, when combined with two-photon input and coincidence measurements, it is shown that such interferometers have capabilities beyond those of standard beam-splitter-based interferometers, such as easily controlled interpolation between Hong-Ou-Mandel (HOM) and anti-HOM behavior. Further, it is shown that the Grover-based analog of the Mach-Zehnder interferometer can make three separate phase measurements simultaneously. By arranging the transmission lines between the two multiports to lie in different planes, the same interferometer acts as a higher-dimensional Sagnac interferometer, allowing rotation rates about three different axes to be measured with a single device.
We present a low-resource and robust optical implementation of the four-dimensional Grover coin, a four-port linear-optical scatterer that augments the low dimensionality of a regular beam-splitter. While prior realizations of the Grover coin required a potentially unstable ring cavity to be formed, this version of the scatterer does not exhibit any internal interference. When this Grover coin is placed in another system, it can be used for interferometry with a higher-dimensional set of optical field modes. In this case, we formed a Grover-Michelson interferometer, which results when the traditional beam-splitter of a Michelson interferometer is replaced with a four-port Grover coin. This replacement has been shown to remove a phase parameter redundancy in the original Michelson system, now allowing continuous tuning of the shape and slope of the interference pattern. We observed an intensity interferogram with 97% visibility and a phase sensitivity more than an order of magnitude larger than a regular Michelson interferometer. Because this device is readily formed with nearly the same number of optomechanical resources as a Michelson interferometer but can outperform it drastically in phase delay evaluation, it has a great potential to improve many interferometric sensing and control systems.
Here we introduce interferometric devices by combining optical feedback (cavities) with unbiased multiports, which, unlike traditional beam dividers, allow light to reflect back out of the port from which it originated. By replacing the traditional, directionally biased beam-splitter in a Michelson interferometer with an unbiased multiport, the functional dependence of the scattering amplitudes changes. As a result, the derivative of transmittance with respect to an external phase perturbation can be made substantially large. This significantly enhances the resolution of phase measurement and allows the phase response curves to be altered in real time by tuning an externally controllable phase shift.
A new nonlinear Sagnac interferometer (NSI) is proposed by replacing the beam-splitter in the traditional Sagnac interferometer (TSI) with a four-wave mixing process. Such a NSI has better angular velocity sensitivity than the one of the TSI. The standard quantum limit can be beaten and the Heisenberg Limit can even be reached for the ideal case by the NSI. We study the effect of the losses on the angular velocity sensitivity of the NSI and find that the optimal angular velocity, where the best angular velocity sensitivity can be obtained, of the NSI may be dependent on the losses inside the interferometer. Such a NSI has its advantages compared with the TSI and may find its potential applications in quantum metrology.
Using symmetry considerations, we derive a unitary scattering matrix for a three-port optical Y coupler or Y branch. The result is shown to be unique up to external phase shifts. Unlike traditional passive linear-optical one-way splitters, coupling light into the conventional output ports of the Y coupler results in strong coherent back-reflections, making the device a hybrid between feed-forward devices like the beam splitter, which do not reverse the direction of light, and a recently considered class of directionally unbiased multiport scatterers (with dimension greater than two), which do. While the device could immediately find use as a novel scattering vertex for the implementation of quantum walks, we also design a few simple but nonetheless useful optical systems that can be constructed by taking advantage of the symmetry of the scattering process. This includes an interference-free, resource-efficient implementation of the Grover four-port and a higher-dimensional Fabry-Perot interferometer with tunable finesse. Symmetry-breaking generalizations are also considered.