Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2412.06338 · New Journal of Physics

Determining absolute neutrino mass using quantum technologies

Alan A. S. Amad, Frank F. Deppisch, M. Fleck, John C. Gallop, T. Goffrey, L Hao, Nathan Higginbotham, S. D. Hogan, S. Jones, Lijie Li, Nicola McConkey, Vincenzo Monachello, Ryan James Nichol, Jamie Potter, Yorck A. Ramachers, Ruben Saakyan, Emilia Sedzielewski, Daniel Swinnock, D. S. Waters, S. Withington, Songyuan Zhao, Junwen Zou

Published Mar 27, 2025• 16 citations
arXivHTMLPDF

Abstract

Abstract Next generation tritium decay experiments to determine the absolute neutrino mass require high-precision measurements of β -decay electron energies close to the kinematic end point. To achieve this, the development of high phase-space density sources of atomic tritium is required, along with the implementation of methods to control the motion of these atoms to allow extended observation times. A promising approach to efficiently and accurately measure the kinetic energies of individual β -decay electrons generated in these dilute atomic gases, is to determine the frequency of the cyclotron radiation they emit in a precisely characterised magnetic field. This cyclotron radiation emission spectroscopy technique can benefit from recent developments in quantum technologies. Absolute static-field magnetometry and electrometry, which is essential for the precise determination of the electron kinetic energies from the frequency of their emitted cyclotron radiation, can be performed using atoms in superpositions of circular Rydberg states. Quantum-limited microwave amplifiers will allow precise cyclotron frequency measurements to be made with maximal signal-to-noise ratios and minimal observation times. Exploiting the opportunities offered by quantum technologies in these key areas, represents the core activity of the Quantum Technologies for Neutrino Mass project. Its goal is to develop a new experimental apparatus that can enable a determination of the absolute neutrino mass with a sensitivity on the order of 10 meV / c 2 .

DOI
10.1088/1367-2630/adc624

Related papers

Cryogenic source of atomic tritium for neutrino-mass measurements and precision spectroscopy

Aleksei Semakin, Janne Ahokas, Tom Kiilerich +9 more

We propose a concept for a cryogenic source of atomic tritium at sub-Kelvin temperatures and energies suitable for magnetic trapping. The source is based on the dissociation of solid molecular T2 films below 1 K by electrons from a pulsed RF discharge, a technique recently demonstrated for atomic hydrogen, combined with buffer-gas cooling and magnetic confinement. We analyze the key processes limiting the source performance, adsorption, spin exchange and recombination, and show that atomic tritium fluxes exceeding 1e15 1/s at kinetic energies of 100 mK can be achieved at the entrance to the magnetic trap. Such a source would enable Doppler-free two-photon 1S-2S spectroscopy in atomic tritium for high-precision measurements of the triton charge radius, providing a crucial benchmark for bound-state QED and improving the comparison between electronic, muonic, and scattering determinations of nuclear sizes in light systems. Beyond spectroscopy, an atomic tritium source avoids molecular final state broadening in the beta decay and is therefore necessary for next generation neutrino mass measurements; combined with detector technologies such as sub-eV resolution quantum sensors or cyclotron radiation emission spectroscopy, it enables an order of magnitude improvement compared to the current best experimental limit. Additionally, the source can be used to generate a beam of low field seeking deuterium atoms for loading magnetic traps, an important benchmark before trapping tritium atoms, which is useful for precision spectroscopy.

physics.atom-phCross-listedarXiv:2511.08313•Physical Review Research•Nov 12, 2025•1 citation

Recent progress of SPAN towards neutrino mass spectroscopy

Takahiko Masuda, Hideaki Hara, Yuki Miyamoto +6 more

SPAN (Spectroscopy of Atomic Neutrino) project aims to determine the absolute neutrino mass. The process we plan to use is a cooperative de-excitation of atoms in a metastable level emitting a neutrino pair associated with a photon. The photon energy spectrum of this process contains information on the absolute mass of neutrino. Key items of this experiment are a rate amplification using macro-coherence in a target medium in case of plural particles emission and an external triggering of the emission in order to scan the spectrum. We have demonstrated the rate amplification in two-photon emission from para-hydrogen gas which was coherently excited to its first vibrationally excited state. The coherence in the medium was generated by irradiating two driving laser pulses. The emission was stimulated by irradiating a mid-infrared laser pulse. The enhancement factor of more than 10 18 with respect to the spontaneous emission was achieved. This paper briefly summarizes the results.

Journal of Physics Conference Series•May 1, 2016•1 citation

Cavity control in a single-electron quantum cyclotron

David Hanneke

A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.

•Jan 1, 2007•0 citations

Quantum metrology for high frequency electric fields

Bruno Eckmann, Tilman Zibold, Johannes Paul Hoffmann +1 more

Quantum systems obeying well-defined laws of physics are very attractive metrological sensors. In principle, they are intrinsically calibrated and allow direct traceability to the SI system. Several fundamental and derived units are nowadays already based on the properties of quantum systems. Neutral atoms are e.g. used for the realization of the second. Leveraging the advantageous properties of such systems to other derived units and establishing traceability still represents a significant challenge, as real-life macroscopic scales must be linked with the microscopic quantum world. In this work, we investigate the use of a vapor of neutral atoms as a highly sensitive probe for electric fields in the microwave domain. By optically exciting the atoms to high-energy states—known as Rydberg states—the atoms become extremely sensitive to electric fields due to their large electric dipole moment. Through optical readout of the atomic state, this enhanced sensitivity can be exploited to turn the atoms into precise sensors for electric fields. In contrast to classical methods of measuring electric fields using metallic probes or antennas, a dilute atomic vapor has the distinct advantage of exerting only minimal influence on the fields being measured. In this study, we aim to leverage these benefits in an experiment designed to measure microwave electric field distributions above a coplanar waveguide structure with high precision and spatial resolution. In order to translate the high accuracy of the atomic sensors to accurate measurements of electrical parameters of the coplanar structure like power, voltage standing wave ratio or S-parameters, we plan to integrate the coplanar waveguide structure into a large atomic vapor cell where it is directly surrounded by the atomic gas. In this case the fields are only minimally disturbed by the vapor cell itself and allow for simple models to translate field measurements into electrical measurements. The methods we are developing in this project are not only aiming to provide traceable measurements for high frequency electrometry but also have the potential to be extended to higher frequency in the terahertz regime or to high resolution imaging of electric field distributions.

•Jan 1, 2025•0 citations

Boosting Axion Searches with Quantum Sensing

Claudio D. Gatti

The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.

IEEE Workshop on Low Temperature Electronics (WOLTE)•Apr 12, 2021•1 citation

Quantum Information as a New Lens for Precision Neutrino Physics

Khushboo Dixit, Ritam Kundu, Papia Panda +2 more

We present a quantum-information-theoretic study of three-flavor neutrino oscillations in long-baseline experiments by mapping flavor states to qubit-like representations and quantifying quantum correlations through total concurrence. The local minima of this entanglement measure identify energy regions where the flavor state is closest to separability, enabling cleaner extraction of oscillation parameters. We explain how these local minima offer opportunities for precision measurements and provide insight into the accurate determination of neutrino oscillation parameters. We then propose a strategy to improve parameter extraction by aligning the benchmark oscillation regions of NO$ν$A and T2K with the minimum entanglement achievable in each experiment. This shifts the concurrence minima toward higher-event-count energy regions, leading to tighter constraints and reducing the tension arising from their different energy regimes. For normal ordering, we obtain $(0.581^{+0.0136}_{-0.0150},195^{+38}_{-32}\,^\circ)$ in the $(\sin^2θ_{23},δ_{\rm CP})$ plane and $(0.580^{+0.0140}_{-0.0153},2.515^{+0.0344}_{-0.0344}\times10^{-3}\,\mathrm{eV}^2)$ in the $(\sin^2θ_{23},Δm^2_{31})$ plane, yielding improved joint constraints. Using GLoBES simulations together with real data, we assess how local minima of quantum correlations influence leptonic CP-violation sensitivity, $θ_{23}$ octant-degeneracy resolution, and mass-ordering determination. Our results show that minimizing entanglement can significantly affect these key sensitivities, highlighting quantum information measures as complementary probes of neutrino flavor oscillations and offering new insight into the role of quantum correlations in precision neutrino physics.

hep-phCross-listedarXiv:2606.31996•Journal of High Energy Physics•Jul 1, 2026•5 citations
Abstract Next generation tritium decay experiments to determine the absolute neutrino mass require high-precision measurements of β -decay electron energies close to the kinematic end point. To achieve this, the development of high phase-space density sources of atomic tritium is required, along with the implementation of methods to control the motion of these atoms to allow extended observation times. A promising approach to efficiently and accurately measure the kinetic energies of individual β -decay electrons generated in these dilute atomic gases, is to determine the frequency of the cyclotron radiation they emit in a precisely characterised magnetic field. This cyclotron radiation emission spectroscopy technique can benefit from recent developments in quantum technologies. Absolute static-field magnetometry and electrometry, which is essential for the precise determination of the electron kinetic energies from the frequency of their emitted cyclotron radiation, can be performed using atoms in superpositions of circular Rydberg states. Quantum-limited microwave amplifiers will allow precise cyclotron frequency measurements to be made with maximal signal-to-noise ratios and minimal observation times. Exploiting the opportunities offered by quantum technologies in these key areas, represents the core activity of the Quantum Technologies for Neutrino Mass project. Its goal is to develop a new experimental apparatus that can enable a determination of the absolute neutrino mass with a sensitivity on the order of 10 meV / c 2 .
We propose a concept for a cryogenic source of atomic tritium at sub-Kelvin temperatures and energies suitable for magnetic trapping. The source is based on the dissociation of solid molecular T2 films below 1 K by electrons from a pulsed RF discharge, a technique recently demonstrated for atomic hydrogen, combined with buffer-gas cooling and magnetic confinement. We analyze the key processes limiting the source performance, adsorption, spin exchange and recombination, and show that atomic tritium fluxes exceeding 1e15 1/s at kinetic energies of 100 mK can be achieved at the entrance to the magnetic trap. Such a source would enable Doppler-free two-photon 1S-2S spectroscopy in atomic tritium for high-precision measurements of the triton charge radius, providing a crucial benchmark for bound-state QED and improving the comparison between electronic, muonic, and scattering determinations of nuclear sizes in light systems. Beyond spectroscopy, an atomic tritium source avoids molecular final state broadening in the beta decay and is therefore necessary for next generation neutrino mass measurements; combined with detector technologies such as sub-eV resolution quantum sensors or cyclotron radiation emission spectroscopy, it enables an order of magnitude improvement compared to the current best experimental limit. Additionally, the source can be used to generate a beam of low field seeking deuterium atoms for loading magnetic traps, an important benchmark before trapping tritium atoms, which is useful for precision spectroscopy.
SPAN (Spectroscopy of Atomic Neutrino) project aims to determine the absolute neutrino mass. The process we plan to use is a cooperative de-excitation of atoms in a metastable level emitting a neutrino pair associated with a photon. The photon energy spectrum of this process contains information on the absolute mass of neutrino. Key items of this experiment are a rate amplification using macro-coherence in a target medium in case of plural particles emission and an external triggering of the emission in order to scan the spectrum. We have demonstrated the rate amplification in two-photon emission from para-hydrogen gas which was coherently excited to its first vibrationally excited state. The coherence in the medium was generated by irradiating two driving laser pulses. The emission was stimulated by irradiating a mid-infrared laser pulse. The enhancement factor of more than 10 18 with respect to the spontaneous emission was achieved. This paper briefly summarizes the results.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.
Quantum systems obeying well-defined laws of physics are very attractive metrological sensors. In principle, they are intrinsically calibrated and allow direct traceability to the SI system. Several fundamental and derived units are nowadays already based on the properties of quantum systems. Neutral atoms are e.g. used for the realization of the second. Leveraging the advantageous properties of such systems to other derived units and establishing traceability still represents a significant challenge, as real-life macroscopic scales must be linked with the microscopic quantum world. In this work, we investigate the use of a vapor of neutral atoms as a highly sensitive probe for electric fields in the microwave domain. By optically exciting the atoms to high-energy states—known as Rydberg states—the atoms become extremely sensitive to electric fields due to their large electric dipole moment. Through optical readout of the atomic state, this enhanced sensitivity can be exploited to turn the atoms into precise sensors for electric fields. In contrast to classical methods of measuring electric fields using metallic probes or antennas, a dilute atomic vapor has the distinct advantage of exerting only minimal influence on the fields being measured. In this study, we aim to leverage these benefits in an experiment designed to measure microwave electric field distributions above a coplanar waveguide structure with high precision and spatial resolution. In order to translate the high accuracy of the atomic sensors to accurate measurements of electrical parameters of the coplanar structure like power, voltage standing wave ratio or S-parameters, we plan to integrate the coplanar waveguide structure into a large atomic vapor cell where it is directly surrounded by the atomic gas. In this case the fields are only minimally disturbed by the vapor cell itself and allow for simple models to translate field measurements into electrical measurements. The methods we are developing in this project are not only aiming to provide traceable measurements for high frequency electrometry but also have the potential to be extended to higher frequency in the terahertz regime or to high resolution imaging of electric field distributions.
The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.
We present a quantum-information-theoretic study of three-flavor neutrino oscillations in long-baseline experiments by mapping flavor states to qubit-like representations and quantifying quantum correlations through total concurrence. The local minima of this entanglement measure identify energy regions where the flavor state is closest to separability, enabling cleaner extraction of oscillation parameters. We explain how these local minima offer opportunities for precision measurements and provide insight into the accurate determination of neutrino oscillation parameters. We then propose a strategy to improve parameter extraction by aligning the benchmark oscillation regions of NOνννA and T2K with the minimum entanglement achievable in each experiment. This shifts the concurrence minima toward higher-event-count energy regions, leading to tighter constraints and reducing the tension arising from their different energy regimes. For normal ordering, we obtain (0.581−0.0150+0.0136,195−32+38 ∘)(0.581^{+0.0136}_{-0.0150},195^{+38}_{-32}\,^\circ)(0.581−0.0150+0.0136​,195−32+38​∘) in the (sin⁡2θ23,δCP)(\sin^2θ_{23},δ_{\rm CP})(sin2θ23​,δCP​) plane and (0.580−0.0153+0.0140,2.515−0.0344+0.0344×10−3 eV2)(0.580^{+0.0140}_{-0.0153},2.515^{+0.0344}_{-0.0344}\times10^{-3}\,\mathrm{eV}^2)(0.580−0.0153+0.0140​,2.515−0.0344+0.0344​×10−3eV2) in the (sin⁡2θ23,Δm312)(\sin^2θ_{23},Δm^2_{31})(sin2θ23​,Δm312​) plane, yielding improved joint constraints. Using GLoBES simulations together with real data, we assess how local minima of quantum correlations influence leptonic CP-violation sensitivity, θ23θ_{23}θ23​ octant-degeneracy resolution, and mass-ordering determination. Our results show that minimizing entanglement can significantly affect these key sensitivities, highlighting quantum information measures as complementary probes of neutrino flavor oscillations and offering new insight into the role of quantum correlations in precision neutrino physics.