Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2411.12835 · Physical Review Applied

Measuring photon correlation using imperfect detectors

Rachel N. Clark, Sam G. Bishop, Joseph K. Cannon, John Patrick Hadden, Philip R. Dolan, Alastair G. Sinclair, Anthony J. Bennett

Published Dec 18, 2024• 4 citations
arXivHTMLPDF

Abstract

Single-photon detectors are “blind” after the detection of a photon, and thereafter display a characteristic recovery in efficiency, during which the number of undetected photons depends on the statistics of the incident light. We show how the efficiency recovery, photon statistics, and intensity have an interdependent relationship which suppresses a detector’s ability to count photons and measure correlations. We also demonstrate this effect with an experiment using n such detectors to determine the n th -order correlation function with pseudothermal light. Published by the American Physical Society 2024

DOI
10.1103/physrevapplied.22.064067

Related papers

Calibrating single-photon detectors for photon counting and quantum correlation measurements

Anthony J. Bennett, Rachel Clark

Photonic quantum technologies require single photon sources and detectors operating at high efficiency, but at high rates detector imperfections can lead to inaccurate measurements. We show that the combination of the detector deadtime and the source statistics together determine the saturation level of a single photon detector, with anti-bunched sources leading to a greater detection rate than coherent or thermal light of the same intensity. At high photon rates this behavior distorts second-, third- and fourth- order correlation measurements, in agreement with our numerical simulations. Finally, we discuss the implications for entangled light detection and photonic logic.

Quantum Sensing and Nano Electronics and Photonics•Mar 4, 2022•0 citations

Photon counting statistics with imperfect detectors

Aleksei Reutov, Сыч Денис Васильевич

Abstract Measurement of photon statistics is an important tool for the verification of quantum properties of light. Due to the various imperfections of real single photon detectors, the observed statistics of photon counts deviates from the underlying statistics of photons. Here we analyze statistical properties of coherent states, and investigate a connection between Poissonian distribution of photons and sub-Poissonian distribution of photon counts due to the detector dead-time corrections. We derive a functional dependence between the mean number of photons and the mean number of photon counts, as well as connection between higher-order statistical moments, for the pulsed or continuous wave coherent light sources, and confirm the results by numerical simulations.

Journal of Physics Conference Series•Dec 1, 2021•0 citations

Analysis and measurement of high-order photon correlations of light fields

Yanqiang Guo, Lijing Wang, Yu Wang +3 more

High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.

Acta Physica Sinica•Jan 1, 2020•3 citations

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•26 citations

Detector imperfections in photon-pair source characterization

Pavel Sekatski, Nicolas Sangouard, Félix Bussières +3 more

We analyse how imperfections in single-photon detectors impact the characterization of photon-pair sources. We perform exact calculations to reveal the effects of multi-pair emissions and of noisy, non-unit efficiency, nonphoton-number resolving detections on the Cauchy–Schwarz parameter, on the second-order auto-correlation and cross-correlation functions, and on the visibilities of both Hong–Ou–Mandel and Bell-like interferences. We consider sources producing either two-mode squeezed states or states with a Poissonian photon distribution. The proposed formulas are useful in practice to determine the impacts of multi-pair emissions and dark counts in standard tests used in quantum optics.

arXiv:1109.0194•Journal of Physics B Atomic Molecular and Optical Physics•Jun 8, 2012•65 citations

Optical Absorption Measurements with Parametric Down-Converted Photons

Zhi Gao Zhao, Kent A. Meyer, William B. Whitten +1 more

It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.

Analytical Chemistry•Aug 26, 2008•3 citations
Single-photon detectors are “blind” after the detection of a photon, and thereafter display a characteristic recovery in efficiency, during which the number of undetected photons depends on the statistics of the incident light. We show how the efficiency recovery, photon statistics, and intensity have an interdependent relationship which suppresses a detector’s ability to count photons and measure correlations. We also demonstrate this effect with an experiment using n such detectors to determine the n th -order correlation function with pseudothermal light. Published by the American Physical Society 2024
Photonic quantum technologies require single photon sources and detectors operating at high efficiency, but at high rates detector imperfections can lead to inaccurate measurements. We show that the combination of the detector deadtime and the source statistics together determine the saturation level of a single photon detector, with anti-bunched sources leading to a greater detection rate than coherent or thermal light of the same intensity. At high photon rates this behavior distorts second-, third- and fourth- order correlation measurements, in agreement with our numerical simulations. Finally, we discuss the implications for entangled light detection and photonic logic.
Abstract Measurement of photon statistics is an important tool for the verification of quantum properties of light. Due to the various imperfections of real single photon detectors, the observed statistics of photon counts deviates from the underlying statistics of photons. Here we analyze statistical properties of coherent states, and investigate a connection between Poissonian distribution of photons and sub-Poissonian distribution of photon counts due to the detector dead-time corrections. We derive a functional dependence between the mean number of photons and the mean number of photon counts, as well as connection between higher-order statistical moments, for the pulsed or continuous wave coherent light sources, and confirm the results by numerical simulations.
High-order photon correlations of light fields are important for characterizing the quantum nature. Since Hanbury Brown and Twiss conducted the pioneering experiments in the 1950s, the HBT effect has inspired extensive research on high-order photon correlation in quantum optics, quantum information, and quantum imaging. The Single-photon counting module is one of the most widely used single-photon detectors. Due to its high detection efficiency and low dark counts in the visible and near-infrared region, it is reasonably chosen for basic research on quantum mechanics. Many researches have demonstrated that the maximum value of second-order photon correlation g(2)(τ) at zero delay (τ = 0) can be used to distinguish different light fields. Therefore, the HBT scheme containing two single photon detectors have been widely used in many advanced studies, such as space interference, ghost imaging, single photon detection with high efficiency, etc. However, higher-order photon correlations g(n) (n > 2) can reveal more measurable characteristics of light fields, such as information about the non-Gaussian scattering process, the skewness and kurtosis of photon number distribution, etc. When the extended HBT scheme is used to measure higher-order photon correlations, the experimental conditions including quantum efficiency and background noise greatly affect the photon correlation measurement. The influences of the counting rate and resolution time of the detection system on the measurements are also very important and cannot be ignored. Therefore, the comprehensive considering of various influence factors is necessary for accurately measuring the high-order photon correlations and also a challenge. In this paper, we present a method based on double Hanbury Brown-Twiss scheme for the accurate measuring of high-order photon correlations g(n) (n > 2). The system consists of four single photon counting modules and is used to detect and analyze the joint distribution probability of temporal photon correlation. Considering the effects of the background noise and overall efficiency, theoretically, we analyze the correlations of the third- and fourth-order photon with the incident light intensity, squeezing parameter and photon number respectively for thermal state, coherent state, squeezed vacuum state, and Fock state. Meanwhile, experimentally we study the influences of resolution time and counting rate on correlations of the coherent state and thermal state with third- and fourth-order photon. On condition that the resolution time is 210 ns and the counting rate is 80 kc/s, the correlations of third and fourth-order photon with the thermal state at zero time delay are accurately measured, and the relative statistical deviations of the measured vales from the theoretical values are 0.3% and 0.8%, respectively. In addition, the third- and fourth-order photon correlations of the thermal state at different delay times are also observed. It is demonstrated that the high-order photon correlations of light fields are measured accurately by comprehensively analyzing various influencing factors. This technique provides a promising and useful tool to investigate quantum correlated imaging and quantum coherence of light fields.
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
We analyse how imperfections in single-photon detectors impact the characterization of photon-pair sources. We perform exact calculations to reveal the effects of multi-pair emissions and of noisy, non-unit efficiency, nonphoton-number resolving detections on the Cauchy–Schwarz parameter, on the second-order auto-correlation and cross-correlation functions, and on the visibilities of both Hong–Ou–Mandel and Bell-like interferences. We consider sources producing either two-mode squeezed states or states with a Poissonian photon distribution. The proposed formulas are useful in practice to determine the impacts of multi-pair emissions and dark counts in standard tests used in quantum optics.
It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.