Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2410.07720 · Optics Express

Influence of optical aberrations on the accuracy of an atomic gravimeter

Louis Pagot, Sébastien Merlet, Franck Pereira dos Santos

Published Dec 15, 2024• 5 citations
arXivHTMLPDF

Abstract

We present numerical simulations of the impact of laser beam wavefront aberrations in cold atom interferometers. We demonstrate that to reach accuracy at the mrad level, it is insufficient to base simulations on a description of retroreflective optics using only low-order Zernike polynomials, as the results will then depend on the decomposition order and the decomposition technique chosen. Moreover, simulations with high-order Zernike polynomials or equivalently high spatial frequency components require the propagation of aberrations to be taken into account, rather than adding them to the ideally propagated beam. Finally, we examine the impact of the parameters of the atomic source and show that the use of a delta-kicked atomic cloud would efficiently mitigate the impact of this systematic effect.

DOI
10.1364/oe.544378

Related papers

Rejection of wavefront aberrations in an atomic gradiometer

Louis Pagot, Sébastien Merlet, Leonid A Sidorenkov +1 more

One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.

physics.atom-phCross-listedarXiv:2511.07013•Optics Express•Nov 11, 2025•0 citations

Improving the Accuracy of Atom Gravimeters with Ultracold Sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•0 citations

Observing the effect of wave-front aberrations in an atom interferometer by modulating the diameter of Raman beams

Min-Kang Zhou, Qin Luo, Lele Chen +2 more

The effect of wavefront aberrations is one of the most important systematic errors in atom interferometers and limits the accuracy of precision atom gravimeters. A detailed theoretical analysis of this effect is presented, and a theoretical method for observing this effect is proposed and demonstrated in experiment. In addition, with this method, the surface quality of the optical elements in the Raman system was measured with a rms resolution of $0.01\ensuremath{\lambda}$.

Physical Review A•Apr 11, 2016•45 citations

Improving the accuracy of atom interferometers with ultracold sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.

arXiv:1804.04909•New Journal of Physics•Nov 13, 2018•130 citations

Active Control of Laser Wavefronts in Atom Interferometers

Azer Trimeche, Mehdi Langlois, Sébastien Merlet +1 more

Optical aberrations in light-pulse atom interferometers are a major limitation in the accuracy and stability of these quantum sensors. In a proof-of-principle experiment, the authors use a deformable mirror to actively control the laser wave fronts in a cold-atom gravimeter, compensating for the distortions induced by optical elements. This fine control of wave fronts opens perspectives for atom interferometry, with applications in navigation, space physics, and high-precision metrology.

arXiv:1704.07088•Physical Review Applied•Mar 23, 2017•47 citations

In situ measurement of the wavefront phase shift in an atom interferometer

Wen-Jie Xu, Jie Liu, Qin Luo +2 more

Wavefront aberrations have significant impacts on the accuracy and long-term stability of cold-atom interferometers. This research presents an in situ method for directly measuring the phase shift induced by the wavefront of the Raman beam using the atom interferometer itself. To validate the feasibility of this approach, experiments involving the insertion of a glass plate with a known surface figure into the Raman beam path have been carried out. The phase introduced by the glass plate is measured experimentally by the atom interferometer and calculated theoretically based on the wavefront obtained from the wavefront sensor, and we find good agreement of the experimental results with the theoretical calculations. The method not only allows for the assessment of systematic errors in an atom interferometer, but also provides the capability to retroactively compute the wavefront of Raman beams based on the measured phase shift. The wavefront distribution of the glass plate is inversed from the phase measured by the atom interferometer. This inversed wavefront distribution is consistent with the surface of the glass plate measured by the wavefront sensor, which confirms the effectiveness of the method. This work provides a valuable approach to evaluate the systematic errors in atom interferometers that are sensitive to wavefront aberrations. Furthermore, it offers a novel method to measure the wavefront using atoms.

Physical Review Applied•Nov 6, 2024•6 citations
We present numerical simulations of the impact of laser beam wavefront aberrations in cold atom interferometers. We demonstrate that to reach accuracy at the mrad level, it is insufficient to base simulations on a description of retroreflective optics using only low-order Zernike polynomials, as the results will then depend on the decomposition order and the decomposition technique chosen. Moreover, simulations with high-order Zernike polynomials or equivalently high spatial frequency components require the propagation of aberrations to be taken into account, rather than adding them to the ideally propagated beam. Finally, we examine the impact of the parameters of the atomic source and show that the use of a delta-kicked atomic cloud would efficiently mitigate the impact of this systematic effect.
One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.
Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.
We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10 nm s −2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s −2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.
Wavefront aberrations have significant impacts on the accuracy and long-term stability of cold-atom interferometers. This research presents an in situ method for directly measuring the phase shift induced by the wavefront of the Raman beam using the atom interferometer itself. To validate the feasibility of this approach, experiments involving the insertion of a glass plate with a known surface figure into the Raman beam path have been carried out. The phase introduced by the glass plate is measured experimentally by the atom interferometer and calculated theoretically based on the wavefront obtained from the wavefront sensor, and we find good agreement of the experimental results with the theoretical calculations. The method not only allows for the assessment of systematic errors in an atom interferometer, but also provides the capability to retroactively compute the wavefront of Raman beams based on the measured phase shift. The wavefront distribution of the glass plate is inversed from the phase measured by the atom interferometer. This inversed wavefront distribution is consistent with the surface of the glass plate measured by the wavefront sensor, which confirms the effectiveness of the method. This work provides a valuable approach to evaluate the systematic errors in atom interferometers that are sensitive to wavefront aberrations. Furthermore, it offers a novel method to measure the wavefront using atoms.