Detection of single-electron charges in solid-state nanodevices is a key technique in semiconductor quantum bit readout for quantum information processing and probing electronic properties of nanostructures. This detection has been achieved using gate-based readouts and sensitive charge sensors including quantum dot charge sensors, with their detection speed enhanced by high-speed rf reflectometry. Recently, real-time processing of data from rf reflectometry has attracted much attention to quantum information processing. In this paper, we propose a sequential method based on Bayes' theorem for estimating the charge state and compare its performance with the averaging approach and threshold judgment. When the noise variance differs between the empty and occupied states, the Bayesian approach demonstrates a lower error score, facilitating the extraction of more data points in real-time charge state estimation. In addition, the Bayesian approach outperforms the averaging method and threshold judgment in terms of error rates for charge state estimation, even during charge transitions. This technique is broadly applicable to single-electron detection and holds substantial utility for quantum bit readout and the operation of nanoprobes that utilize single-electron detection.
Detection of single-electron charges in solid-state nanodevices is a key technique in semiconductor quantum bit readout for quantum information processing and probing electronic properties of nanostructures. This detection has been achieved using gate-based readouts and sensitive charge sensors including quantum dot charge sensors, with their detection speed enhanced by high-speed rf reflectometry. Recently, real-time processing of data from rf reflectometry has attracted much attention to quantum information processing. In this paper, we propose a sequential method based on Bayes' theorem for estimating the charge state and compare its performance with the averaging approach and threshold judgment. When the noise variance differs between the empty and occupied states, the Bayesian approach demonstrates a lower error score, facilitating the extraction of more data points in real-time charge state estimation. In addition, the Bayesian approach outperforms the averaging method and threshold judgment in terms of error rates for charge state estimation, even during charge transitions. This technique is broadly applicable to single-electron detection and holds substantial utility for quantum bit readout and the operation of nanoprobes that utilize single-electron detection.
The operation of solid-state qubits often relies on single-shot readout using a nanoelectronic charge sensor, and the detection of events in a noisy sensor signal is crucial for high fidelity readout of such qubits. The most common detection scheme, comparing the signal to a threshold value, is accurate at low noise levels but is not robust to low-frequency noise and signal drift. We describe an alternative method for identifying charge sensor events using wavelet edge detection. The technique is convenient to use and we show that, with realistic signals and a single tunable parameter, wavelet detection can outperform thresholding and is significantly more tolerant to 1/f and low-frequency noise.
Quantum information protocols, such as quantum error correction and quantum phase estimation, have been widely used to enhance the performance of quantum sensors. While these protocols have relied on single-shot detection, in most practical applications only an averaged readout is available, as in the case of room-temperature sensing with the electron spin associated with a nitrogen-vacancy center in diamond. Here, we theoretically investigate the application of the quantum phase estimation algorithm for high dynamic-range magnetometry, when single-shot readout is not available. We show that, even in this case, Bayesian estimation provides a natural way to efficiently use the available information. We apply Bayesian analysis to achieve an optimized sensing protocol for estimating a time-independent magnetic field with a single electron spin associated to a nitrogen-vacancy center at room temperature and show that this protocol improves the sensitivity over previous protocols by more than a factor of 3. Moreover, we show that an extra enhancement can be achieved by considering the timing information in the detector clicks.
This thesis focuses on implementing radio frequency (rf) reflectometry techniques for dispersive detection of charge and spin dynamics in nanoscale devices. I have investigated three aspects of rf reflectometry using state-of-the-art silicon (Si) complementary metal-oxide-semiconductor (CMOS) nanowire field effect transistors (NWFETs). First, a high-sensitivity capacitive gate-based charge sensor is developed by optimising the external matching circuit to detect capacitive changes in the high frequency resonator. A new circuit topology is used where superconducting niobium nitride (NbN) inductor is connected in parallel with a single-gate Si NWFET resulting in resonators with loaded Q-factors in the 400-800 range. For a resonator operating at 330 MHz, I have achieved a charge sensitivity of 7.7 μe/Hz and, when operating at 616 MHz, I get 1.3 μe/Hz. This gate-based sensor can be used for fast, accurate and scalable techniques for quantum state readout in Si CMOS based quantum computing. Second, this new circuit topology for the resonator is used with a dual-gate Si NWFET. This dual-gate device geometry provides access to a double quantum dot (DQD) system in few electron regime. The spin-state of the two-electron DQD system is detected dispersively using Pauli spin blockade between joint singlet S(2,0) and triplet T−(1,1) states in a finite magnetic field B. The singlet-triplet relaxation time T1 at B=4.5~T is measured to be $\sim$1 ms using standard homodyne detection technique. Third, I expand the range of applications of gate-based sensing to accurate temperature measurements. I have experimentally demonstrated a primary thermometer by embedding a single-gate Si NWFET with the rf capacitive gate-based sensor. The thermometer, termed as gate-based electron thermometer (GET), relies on cyclic electron tunneling between discrete energy levels of a quantum dot and a single electron reservoir in the NWFET. I have found that the full-width-half-maximum (FWHM) of the resonator phase response depends linearly with temperature via well known physical law by using the ratio kB/e between the Boltzmann constant and the electron charge. The GET is also found to be magnetic field independent like other primary thermometers such as Coulomb blockade and shot noise thermometers.
Radio-frequency (rf) reflectometry offers a fast and sensitive method for charge sensing and spin readout in gated quantum dots. We focus in this work on the implementation of rf readout in accumulation-mode gate-defined quantum dots, where the large parasitic capacitance poses a challenge. We describe and test two methods for mitigating the effect of the parasitic capacitance, one by on-chip modifications and a second by off-chip changes. We demonstrate that on-chip modifications enable high-performance charge readout in Si/Six${\mathrm{Ge}}_{1\ensuremath{-}x}$ quantum dots, achieving a fidelity of 99.9% for a measurement time of $1\phantom{\rule{0.2em}{0ex}}\ensuremath{\mu}\mathrm{s}$.
Charge sensing is a sensitive technique for probing quantum devices, of particular importance for spin-qubit readout. To achieve good readout sensitivities, the proximity of the charge sensor to the device to be measured is a necessity. However, this proximity also means that the operation of the device affects, in turn, the sensor tuning and ultimately the readout sensitivity. We present an approach for compensating for this crosstalk effect allowing for the gate voltages of the measured device to be swept in a 1-V × 1-V window while maintaining a sensor configuration chosen by a Bayesian optimizer. Our algorithm will hopefully be a major contribution to the suite of fully automated solutions required for the operation of large quantum device architectures. Published by the American Physical Society 2024
We report the dispersive charge-state readout of a double quantum dot in the few-electron regime using the in situ gate electrodes as sensitive detectors. We benchmark this gate sensing technique against the well established quantum point contact charge detector and find comparable performance with a bandwidth of $\ensuremath{\sim}10\text{ }\text{ }\mathrm{MHz}$ and an equivalent charge sensitivity of $\ensuremath{\sim}6.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}3}\text{ }\text{ }e/\sqrt{\mathrm{Hz}}$. Dispersive gate sensing alleviates the burden of separate charge detectors for quantum dot systems and promises to enable readout of qubits in scaled-up arrays.