Accurate thermometry of laser-cooled ions is crucial for the performance of the trapped-ion quantum computing platform. However, most existing methods face a computational exponential bottleneck. Recently, a thermometry method based on bichromatic driving was theoretically proposed by Vybornyi et al. [PRX Quantum 4, 040346 (2023)] to overcome this obstacle, which allows the computational complexity to remain constant with the increase of ion numbers. In this paper, we provide a detailed statistical analysis of this method and prove its robustness regarding several imperfect experimental conditions using Floquet theory. We then experimentally verify its good performance on a linear-segmented-surface-electrode-ion-trap platform. This method is proven to be effective from near the motional ground state to a few mean phonon numbers. Our theoretical analysis and experimental verification demonstrate that the scheme can accurately and efficiently measure the temperature in ion crystals.
Accurate thermometry of laser-cooled ions is crucial for the performance of the trapped-ion quantum computing platform. However, most existing methods face a computational exponential bottleneck. Recently, a thermometry method based on bichromatic driving was theoretically proposed by Vybornyi et al. [PRX Quantum 4, 040346 (2023)] to overcome this obstacle, which allows the computational complexity to remain constant with the increase of ion numbers. In this paper, we provide a detailed statistical analysis of this method and prove its robustness regarding several imperfect experimental conditions using Floquet theory. We then experimentally verify its good performance on a linear-segmented-surface-electrode-ion-trap platform. This method is proven to be effective from near the motional ground state to a few mean phonon numbers. Our theoretical analysis and experimental verification demonstrate that the scheme can accurately and efficiently measure the temperature in ion crystals.
In a trapped-ion system, accurate thermometry of ions is crucial for precisely evaluating the system state and performing quantum operations. However, when the motional state of a single ion is far away from the ground state, the spatial dimensionality of the phonon state sharply increases. Then it is difficult to realize accurate and mode-resolved thermometry with existing methods. In this work, we apply deep learning to the thermometry of a trapped ion and propose an efficient and mode-resolved method for accurately estimating large mean phonon numbers. We have also conducted experimental verification based on a self-developed surface trap. The result has shown the significant accuracy and efficiency of the method for thermometry of a single ion with large mean phonon numbers. The mode-resolved feature of our method makes it better applied to the characterization of system parameters, such as evaluating cooling effectiveness and analyzing surface trap noise. Our trained neural network model can be easily extended to other experimental setups and parameter ranges without modification of the experimental setups.
Coulomb crystals of cold trapped ions are a leading platform for the realization of quantum processors and quantum simulations and, in quantum metrology, for the construction of optical atomic clocks and for fundamental tests of the standard model.For these applications, it is not only essential to cool the ion crystal in all its degrees of freedom down to the quantum ground state but also to be able to determine its temperature with a high accuracy.However, when a large ground-state cooled crystal is interrogated for thermometry, complex many-body interactions take place, making it challenging to accurately estimate the temperature with established techniques.In this work, we present a new thermometry method tailored for ion crystals.The method is applicable to all normal modes of motion and does not suffer from a computational bottleneck when applied to large ion crystals.We test the temperature estimate with two experiments, namely with a one-dimensional linear chain of four ions and a two-dimensional crystal of 19 ions and verify the results, where possible, using other methods.The results show that the new method is an accurate and efficient tool for thermometry of ion crystals.
Ion traps are a foundational technology in quantum information processing, precision spectroscopy and foundational physics tests. At the heart of their performance is the inhibition of micromotion, an oscillation of ions through imperfect trapping potentials, that restricts the laser cooling efficiency, coherence times, and the accuracy of measurements. The paper provides a systematic computational analysis of four different electrode geometries (Linear Paul, Segmented, Surface and Ring) in 24 different RF / DC configurations (C01-C24) and 13 performance parameters that comprise trap depth (0.62 1.48 eV), radial secular frequency (1,100 1 Multi-objective optimization with weighted scoring of these metrics indicates that Ring trap geometry scores the highest total (80.2/100), followed by Linear Paul (72.0), Segmented (67.0) and Surface (55.1) configurations. ANOVA (one-way) statistically verified the presence of statistically significant inter-geometry differences in micro-motions amplitude (F = 18.43, p < .001) and cooling efficiency (F = 22.17, p < .001), with Tukey HSD post-hoc revealed that the most significant difference was between the Ring and the Surface. The Pearson correlation analysis shows that RF drive voltage and micromotion amplitude (r = -0.94 to -0.99) and cooling efficiency and micromotion (r = -1.00) have near-perfect inverse correlations, which prove that the quality of confinement is regulated by electrode geometry, RF amplitude, and spacing. These results give quantitative design principles of next-generation ion traps in quantum computing and atomic clock. Keywords: ion trap, micromotion minimization, RF/DC electrode optimization, laser cooling, Mathieu stability, secular frequency, quantum computing
We propose and characterize a protocol for rapid near-ground state cooling of the center-of-mass (c.m.) mode of a large trapped ion crystal. When the initial mean thermal occupation of the mode nˉi is small compared to the number of ions N, a red sideband drive implements a beam-splitter type SWAP operation between the mode and the collective spin of the N ions, with the latter effectively serving as a quantum harmonic oscillator. Subsequently, a reset of the spins removes the entropy, leading to near-ground state cooling of the c.m. mode. We term this protocol as quantum beam-splitter cooling (QBSC). We analyze the impact of several practical imperfections on the final temperature achievable under QBSC, including finite ion number, off-resonant carrier and blue-sideband contributions, and the impact of the sideband drives arising from spectator modes. In addition, we outline practical strategies to eliminate the carrier drive. Furthermore, we show that measuring the population statistics of the ions at the end of the SWAP operation can enable near-optimal quantum beam-splitter thermometry (QBST), with the classical Fisher information approaching the quantum Fisher information of a thermal state. We discuss the connection of QBSC with continuous sideband cooling and compare QBST with a recently proposed rapid adiabatic passage-based thermometry scheme. Our work constitutes an example of harnessing many-body effects to open new routes to laser cooling and thermometry in large trapped ion crystals.
We describe and experimentally implement a single-ion local thermometry technique with absolute sensitivity adaptable to all laser-cooled atomic ion species. The technique is based on the velocity-dependent spectral shape of a quasi-dark resonance tailored by two driving fields in a $J\ensuremath{\rightarrow}J$ transition such that the two fields can be derived from the same laser source, leading to a negligible relative phase shift. We validated the method and tested its performance in an experiment on a single 88Sr+ ion cooled in a surface radio-frequency trap. We first applied the technique to characterize the heating rate of the surface trap. We then measured the stationary temperature of the ion as a function of cooling laser detuning in the Doppler regime. The results agree with theoretical calculations, with an absolute error smaller than 100 $\ensuremath{\mu}\mathrm{K}$ at 500 $\ensuremath{\mu}\mathrm{K}$, in a temperature range between 0.5 and 3 mK and in the absence of adjustable parameters. This simple-to-implement and reliable method opens the way to fast absolute measurements of single-ion temperatures in future experiments dealing with heat transport in ion chains or thermodynamics at the single-ion level.
We experimentally demonstrate a method to determine the temperature of trapped ions which is suitable for monitoring fast thermalization processes. We show that observing and analyzing the lineshape of dark resonances in the fluorescence spectrum provides a temperature measurement which is accurate over a large dynamic range, applied to single ions and small ion crystals. Laser induced fluorescence is detected over a time of only , allowing for rapid determination of the ion temperature. In the measurement range of 10 −1 – mK we reach better than accuracy. Tuning the cooling laser to selected resonance features allows us to control the ion temperatures between mK and more than mK. Experimental work is supported by a solution of the eight-level optical Bloch equations when including the ions' classical motion. This technique paves the way for many experiments, including heat transport in ion strings, heat engines, non-equilibrium thermodynamics or thermometry of large ion crystals.